Xtreme J60 User & Installation Manual Download Page 4

Xtreme Power Conversion Corporation

J60 User’s Manual

Page 4

Uninterruptible Power Supply

Power switch on the back of the UPS. For best results, the batteries in the UPS should be charged for at least 8 

hours before use. The UPS charges its battery while it is connected to AC utility power and powered on.

Connecting the Loads

Plug the loads to be supported by the UPS into the output receptacles on the front of the UPS. Simply turn the 

power switch on the UPS on and the devices connected to the UPS will be protected by the UPS unit.

Turn UPS ON / OFF

To turn the UPS unit on, press the power button on the UPS and hold for three seconds. To turn the UPS unit off, 

press the power button and hold for one second.

Connecting Local Monitoring Software (optional)

If it is desired to use the Local Monitoring Software, and if your UPS is equipped with USB communications, con-

nect a USB cable from your computer to the UPS, and install the software from the CD.

Indicators & Alarm Conditions

Condition

Visual Indicator

Alarm

AC mode

LED illuminated

No Audible Alarm

Battery mode

LED flashes every 10 seconds

Audible Alarm sounds every 10 

seconds

Low battery mode

LED flashes every 1 second

Audible Alarm sounds every 1 

second

Fault

LED is illuminated

Audible Alarm is continuous

Alarm for over temperature protec-

tion

LED flashes every 0.5 seconds

No Audible Alarm

Important Safety Instructions: (Save These Instructions)

CAUTION! (UPS having Internal Batteries):

 Risk of electrical shock – Hazardous live parts inside this unit are ener-

gized from the battery supply even when the input AC power is disconnected.

CAUTION! (No User serviceable Parts): 

Risk of electrical shock, do not remove cover. No user serviceable parts 

inside. Refer servicing to qualified service personnel.

CAUTION! (Non-isolated Battery supply): 

Risk of electric shock, battery circuit is not isolated from AC input, haz-

ardous voltage may exist between battery terminals and ground. Test before touching.

WARNING!

 Unit intended for installation in a controlled environment.

CAUTION!

 Do not dispose of batteries in a fire, the battery may explode.

CAUTION!

 Do not open or mutilate the battery, released electrolyte is harmful to the skin and eyes.

CAUTION!

 A battery can present a risk of electric shock and high short circuit current. The following precaution 

should be observed when working on batteries:

•  Remove watches, rings or other metal objects.

•  Use tools with insulated handles.

Summary of Contents for J60

Page 1: ...J60 Lithium Ion UPS 350VA Model User Installation Manual www xpcc com 2018 Xtreme Power Conversion Corporation All rights reserved Rev 5 24 18 ...

Page 2: ...Table of Contents Package Contents 3 ProductIntroduction 3 ProductOverview 3 Installation Initial Startup 3 Indicators Alarm Conditions 4 Important Safety Instructions Save These Instructions 4 Troubleshooting 5 Specifications 6 Obtaining Service 7 Xtreme Power Conversion Limited Warranty 8 ...

Page 3: ...ual to correct the problem If the problem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Product Overview Xtreme J60 advanced design combines the benefits of lithium powered UPS and advanced surge suppression technology Slim form factor just 1 25 wall mounting and easy access receptacles make J60 ideal for mounting behind thin di...

Page 4: ...rm sounds every 10 seconds Low battery mode LED flashes every 1 second Audible Alarm sounds every 1 second Fault LED is illuminated Audible Alarm is continuous Alarm for over temperature protec tion LED flashes every 0 5 seconds No Audible Alarm Important Safety Instructions Save These Instructions CAUTION UPS having Internal Batteries Risk of electrical shock Hazardous live parts inside this unit...

Page 5: ...t the device using the power supply cord Ensure that the equipment is placed in a position near the outlet where easily accessible All servicing on this equipment must be carried out by qualified service personnel Before conducting any maintenance repair or shipment first ensure that everything is turned off completely and disconnected Troubleshooting Condition Visual Indicator Alarm No LED displa...

Page 6: ...ls 2400mAh Battery runtime est 6 min at 100 load 14 min at 50 load PHYSICAL Dimensions W x D x H 6 9 x 8 5 x 1 25 in Weight 3 4 lbs Line cord Detachable 5 15P to C13 3ft C14 inlet Receptacles 3 5 15R 2 IEC C13 ENVIRONMENT Temperature 32 104 F 0 40 C Humidity 0 90 Altitude 11 500 ft above sea level APPROVALS UL 1778 cTUVus FCC and RoHS CE and RoHS WARRANTY 5 years electronics 5 years battery warran...

Page 7: ...sk you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask the ...

Page 8: ...ion personnel or authorized agents This warranty shall be void if a the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifi cations or c the equipment has bee...

Reviews: