During the rainy season, check every day to make sure that the pump is working normally. During high 

winds make sure the power cord is not pulled over the cover, and that the pump is still upright, as well as the 

discharge hose is in the appropriate position. If you are away from home for an extended period of time, ask 

someone to check the pump on a regular basis to make sure everything work properly. When the pump is 

upright the water around the float rises and the float mechanism is activated. when the water level is about 

2 “- 3” deep, the switch starts the pump. Keep the pump running until the water level is about 0.50”-1.50” 

deep. 

NOTE

: If the temperature is close to the freezing point it may lead to the opening height up to 4” and 

the closing height up to 2”. Before servicing the pump, disconnect it from the electrical equipment, unplug the 

power cord, or close the disconnect box. Pump motor housing is completely sealed, no need for maintenance. 

The motor is of continuous operation type, equipped with automatic thermal overload protection device.

Routing maintenance

Keep the pump clean and in good condition at all times. If the float is stuck, remove the float access cover 

at the bottom of the pump. As shown on the cover, turn in the direction of the open arrow and remove the 

cover. Clean as needed, then reinstall the access cover. The pump has an internal vent to prevent air lock.

According to figure 1 and the following steps, the vents will become clogged and need to be cleaned 

regularly.

1.

 Disconnect pump power from electrical equipment.

2.

 Loosen and remove the screws from the blue cover.

3. 

Remove the outer cover

4. 

Clean the vent

5.

 Reinstall the cover and screws.

6. 

Reconnect the pump to the electrical equipment.

1. Be certain electrical outlet to be used meets the requirements of  the  National  Electrical  code,  as  well  

as  local  electrical  codes,  including  grounding,  and  GFCI  protection.  Also  verify  that  outlet  is  properly  

sized  and  located  for  this  pump.  Your  installation may require a certified electrician, or plumber. See 

ELECTRICAL section.  

2. Connect a garden hose to the hose adaptor, or use a 1” nipple and  flexible  PVC  tubing  secured  to  the  

pump  discharge.  NOTE: If flexible 1” PVC tubing is used, secure the free end so that it cannot blow back 

onto the pool cover in high wind.
3. Gently  lower  the  pump  onto  the  pool  cover  by  holding  onto  the  garden  hose.  Do  not  pull  the  

power  cord  plug  onto  the  pool  cover.  Use  rope and a garden hose to position pump onto the pool cover. 

Two people should position the pump, with the first person holding the electrical cord plug and the second 

person positioning the pump  at  the  desired  location  on  the  pool  cover.  

5. Once the pump is in position and proper electrical connections have  been  made,  it  is  ready  for  testing.

WARNING:

 Always disconnect the electrical power before touching the  pump,  discharge,  or  electrical  

plug  when  water  is  present  in  the  area.  Failure  to  do  so  can  result  in  serious  bodily  injury  and/or  

property  damage.  Always  connect  the  pump  to  a  grounded  receptacle. See SAFETY GUIDELINES.

Summary of Contents for 75165

Page 1: ...SPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 75165 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Page 2: ...hock please replace the damaged power cord immediately WARNING To reduce the risk of electric shock do not use an extension cord to connect the pump to the power supply Do not use this pump to deliver chemicals or corrosive liquids which may damage the integrity of the housing and cause an electrical short circuit This pump is used only with water Do not use this pump to deliver gasoline or other ...

Page 3: ... following steps the vents will become clogged and need to be cleaned regularly 1 Disconnect pump power from electrical equipment 2 Loosen and remove the screws from the blue cover 3 Remove the outer cover 4 Clean the vent 5 Reinstall the cover and screws 6 Reconnect the pump to the electrical equipment 1 Be certain electrical outlet to be used meets the requirements of the National Electrical cod...

Page 4: ...3 INSTALLATION TECHNICAL SPECIFICATIONS ...

Page 5: ... STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial number r...

Reviews: