![Xtreme Power 61058 Owner'S Manual And Safety Instructions Download Page 4](http://html.mh-extra.com/html/xtreme-power/61058/61058_owners-manual-and-safety-instructions_890946004.webp)
3
OPERATION
The floor grinder is designed to be used either wet or dry. If the application requires dry grinding, a suitable
industrial vacuum is required.
Consult a Safety Data Sheet for materials being ground. Concrete dust and floor coatings contain materials
that can be harmful.
1.
Make sure the diamond tooling is suitable for the material being ground and the tooling is correctly
balanced.
LEVEL
ADJUSTMENT
FASTENER
LEVEL
ADJUSTMENT
HANDLE
2.
Ensure that the grinding plates are in good condition and properly mounted. Never use damaged tooling.
3.
All countersunk bolts must be tightened to specifications and firmly in place.
4.
Check that the grinding plate is adjusted so that it sits level on the work surface.
5.
Check that all nuts and bolts on the folding handle latch are tight and secure.
6.
Raise the grinding plates from the floor.
7.
Start the motor by pressing the black switch on the starter box.
8.
Lower the grinding plate and begin grinding. Keep the grinding head moving side to side on the work
surface to create an evenly ground surface until desired results are achieved.
STOPPING THE GRINDER
1.
Depress the red STOP button on the start box.
NOTE:
The position of the axle may be adjusted as needed for levelling.
1.
Adjust the vertical grinding position by loosening the level adjustment fastener counter-clockwise.
2.
Lifting the level adjustment handle raises the back end of the grinder.
3.
Lowering the level adjustment handle lowers the back end of the grinder.
4.
Use “Bubble Level”, mounted on the machine as reference.
5.
Secure desired grinder position by tightening the level adjustment fastener clockwise.