Xtreme Power Conversion XC-14A User And Installation Manual Download Page 4

Xtreme Power Conversion Corporation

XC User’s Manual

Page 4

Portable Air Conditioning

IMPORTANT SAFETY INSTRUCTIONS: (SAVE THESE INSTRUCTIONS)

Please read this manual carefully for instructions on correct installation and usage. Please read all safety instruc

-

tions.

1. 

Transport and store the unit in an upright position only. Leave the unit in an upright position for at least 3 

hours before use.

2. 

Always place the unit on an even, level surface.

3. 

Ensure the unit is connected to a grounded utility of the correct rating / capacity.

4. 

The unit will cool when the room temperature is between 64.4°F - 113°F (18°C - 45°C) depending on the 

thermostat setting.

5. 

DO NOT use this unit for functions other than those described in this User’s Manual.

6.  DO NOT tilt the unit.

7. 

DO NOT cover or obstruct the unit’s inlet and/or outlet grilles.

8.  DO NOT use the unit in areas where it will be exposed to rain or water.

9. 

NEVER unplug the unit while it is operating.

WARNING! 

DO NOT use the unit in wet environments, such as a laundry room, to avoid risk of electrical shock.

10. 

DO NOT place any foreign objects on the unit.

11. 

DO NOT operate the unit with wet or damp hands.

12. 

DO NOT allow chemical substances to come in contact with the unit.

13. 

DO NOT operate the unit in the presence of flammable substances or vapors such as alcohols, pesticides, 

gasoline, etc.

WARNING! 

DO NOT operate the unit in explosive or flammable environments.

14. 

DO NOT use the plug to start or to stop the unit. Always use the control panel to start and to stop the unit.

15. 

Always turn off the unit when it is not in use, and unplug the power plug from the electrical outlet.

16.  Always turn the unit off and unplug the main power plug from the electrical outlet before cleaning, mov

-

ing, or performing maintenance.

17. 

AVOID the use of adapter plugs or extension cords. If it is necessary to use an extension cord or an adapter 

plug to operate the unit, ensure that they are correctly rated for the application. Consult local qualified 

electrician and all local electrical codes to ensure proper setup. Any extension cord used with the device 

must be rated for a minimum of 15A.

18.  DO NOT unplug the unit by pulling on the electrical cord. Keep the electrical code away from heat sources 

and always completely unroll the cord to avoid overheating. If the power cord becomes damaged, a quali

-

fied service agent, qualified electrician, or similarly qualified person must replace it, in order to avoid a 

hazard or shock.

WARNING! 

DO NOT operate a unit with a damaged power cord.

19. 

The filters must be used with the product at all times. When the filters are removed for cleaning, always 

ensure that the unit has been turned off and unplugged from the electrical outlet.

20. 

Regularly clean the filters to maintain efficiency. If the filters are not cleaned regularly, the units output 

performance and efficiency will decline and energy consumption will increase.

21. 

DO NOT operate the unit with a damaged power cord or plug, after it malfunctions, or if the unit has been 

dropped or damaged.

22. 

Only use the unit in the upright position on a even, flat surface. Unit must be positioned at least 24 inches 

(60 cm) from the nearest object in any direction.

23. 

Stop operation immediately if abnormal noise or odor is noticed. Contact local service center.

Summary of Contents for XC-14A

Page 1: ...XC Portable Air Conditioning XC 14A XC 22A XC 30A Models User Installation Manual www xpcc com 2015 Xtreme Power Conversion Corporation All rights reserved Rev 1 26 15 ...

Page 2: ...CordHolder 7 RubberStoppers 7 Discharge Ducts Supply Air Duct 8 InstallationGuide 8 Moving the Unit 8 Plugging in the Unit 8 Operation 9 Control Panel 9 Maintenance 10 FilterCleaning 10 SpringReplacement 11 Troubleshooting 11 AlarmCodes 12 TroubleshootingChart 13 Specifications 14 Shipping List 14 Options 14 Obtaining Service 15 Xtreme Power Conversion Limited Warranty 16 ...

Page 3: ...des important information that should be followed during installation and maintenance of the Portable Air Conditioner allowing you to correctly set up your system for the maximum safety and performance Included is information on customer support and service if it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem I...

Page 4: ...f the unit when it is not in use and unplug the power plug from the electrical outlet 16 Always turn the unit off and unplug the main power plug from the electrical outlet before cleaning mov ing or performing maintenance 17 AVOID the use of adapter plugs or extension cords If it is necessary to use an extension cord or an adapter plug to operate the unit ensure that they are correctly rated for t...

Page 5: ... should conduct these installations as failure to acknowledge electrical hazards could prove to be fatal Product Description Xtreme Cooling Portable Air Conditioners feature spot cooling for large areas where cooling of the entire area is not practical or possible A dedicated spot cooling thermostat controls the unit in this application These air condi tioners can also be used in smaller areas for...

Page 6: ...Xtreme Power Conversion Corporation XC User s Manual Page 6 Portable Air Conditioning Assembly Component Parts Front and Right Side View Rear and Left Side View ...

Page 7: ...nit as shown below 3 Use screws to install the Power Cord Holder to the rear of the unit screws inside the accessory box Power Cord Holder attachment Rubber Stoppers 1 Remove the Rubber Stoppers from the accessory box 2 Place the Rubber Stoppers on the rear of the unit as shown below 3 Use screws to install the Rubber Stoppers to the rear of the unit screws inside the accessory box Rubber Stopper ...

Page 8: ...reas where it will be exposed to rain or water WARNING DO NOT use the unit in a corrosive atmosphere WARNING DO NOT use the unit above 113 F 45 C Moving the Unit Unlock the casters and push the unit using the side handles to a flat level surface and set the cater brakes to the locked position Plugging in the Unit Check the prongs and surface of the power cord plug for dust dirt If dust and or dirt...

Page 9: ...roducing cool air 2 minutes after button is pressed Regulates temperature based on outlet cool air temperature 4 ROOM COOL BUTTON Activates compressor and produces cool air 2 minutes after button is pressed Regulates temperature based on inlet ambient air temperature 5 SET TEMP BUTTON Change target temperature data value by 1 Change data value by 10 by pressing continually Press the SET TEMP BUTTO...

Page 10: ...leaner hose attachment If required was the filter in lukewarm water with a mild detergent Leave to dry in a shaded area before reinstall ing Cleaning the Filter 1 To clean the evaporator filter pull the front filter guard forward from the top until the guard is open in an angled position and resting on the supporting cables 2 Slide the filter up and use a vacuum cleaner to remove the dust from the...

Page 11: ...NOT operate the unit with a damaged cord or plug after the unit malfunctions or if the unit has been dropped or damaged Spring Replacement There are two springs on the rear of the condenser water tank guide 1 Release the screw on the spring hook 2 Take off the spring hook and then pull out the opposite spring hook from the hole in the condenser water tank guide 3 Replace with a new spring in rever...

Page 12: ...Ensure exhaust duct is not blocked kinked c Do not use the air condi tioner if ambient tem perature is higher than 113 F 45 C Abnormal temperature sen sor value TH1 temperature sensor has a loose or broken connection Contact a qualified service agent Abnormal temperature sen sor value TH2 temperature sensor has a loose or broken connection Contact a qualified service agent Compressor overloaded a ...

Page 13: ...nt air cannot be properly cooled if the filter is dirty and not regularly cleaned 2 Only the fan operates for 2 minutes after the unit has been started to protect the unit 3 The ambient air temperature may be too high 1 Clean air filter 2 Verify that 2 minutes have passed since the unit was turned on 3 The temperature of the com pressor can be higher when the ambient temperature is too high The co...

Page 14: ...08kW 0 26kW 0 24kW NEMA plug 5 15P 6 15P 6 20P Power cord gauge 12AWG 14AWG 12AWG Power cord length 10 ft 10 ft 10 ft Automatic restart Unit automatically restarts when power is reapplied after outage PHYSICAL Dimensions W x D x H 17 5 x 19 9 x 43 3 in 22 0 x 24 4 x 50 4 in Weight 132 lbs 198 lbs 208 lbs Air filter Aluminum Aluminum vinyl chloride Operating conditions 64 113 F 64 113 F 64 113 F Ho...

Page 15: ...k you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask the T...

Page 16: ...other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifi cations or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions...

Reviews: