XV1013 VACUUM MACHINE TROUBLESHOOTING 

ISSUE

SUGGESTED FIX

No power to  

machine

Check power cable at the back of machine. Make sure it is plugged in securely to both the 
machine and to the wall outlet. 

Item is not  

vacuumed tightly

Different products may require more or less vacuum time to achieve the perfect level of vacuum. 
If MORE vacuum is required INCREASE the VACUUM TIME by 10-15 and retry. 

Item is vacuumed  

too tightly

Different products may require more or less vacuum time to achieve the perfect level of vacuum. 
If MORE vacuum is required DECREASE the VACUUM TIME by 10-15 and retry. 

Pouches are not 

sealed

First try INCREASING the SEALING TIME. If that doesn’t fix the problem, check the sealing wire. If 
it is damaged replace with included extra sealing wire.

Seal is melting 

through pouch

First INSPECT the SEALING BAR. If the sealing bar shows wear or damaged, replace with included 
extra teflon tape strips. If that doesn’t fix the problem, DECREASE the SEALING TIME.

QUICK-START VACUUM MACHINE OPERATION

STEP 1: 

Check vacuum oil level

STEP 6: 

Put product inside pouch & place inside chamber  

                with the open end covering seal bar.

STEP 7: 

Secure pouch with the product hold down bar.  

 

      Press lid down firmly and push start       button.

STEP 8: 

Once the cycle is complete you may remove  

                the sealed package from the vacuum chamber.

STEP 2: 

Plug machine into outlet and turn red power   

                switch on back of machine to “on” position.

STEP 3: 

Push set        button once to set VACUUM time.   

                Use arrows         to adjust the time. 

(default 30)

STEP 4: 

Push set        button twice to set SEALING time.   

                Use arrows         to adjust the time. 

(default 1.5)

STEP 4: 

Push set        button 3x to set COOLING time.   

                Use arrows         to adjust the time. 

(default 4)