(1) ts: Temp. Setting: It is preset 85

(2) td: Temp. Difference setting: it is preset 1

(3) AH: High Temp. Alarm setting: it is preset 99

(4) AL: Low Temp. Alarm setting: it is preset 40

(5) Ht: High temp. Alarm Time Setting: it is preset 1minute.

(6) Lt: Low temp. Alarm Time Setting: it is preset 5 minutes.

(7) tA: Temp. Adjustment: it is preset 0

4.8.2: Program and Time Display: 

The left display is for program and the right display for time (unit: 

second) 

 4.8.2.1: Description of Program display: 

Program: 

(1) 01: the platform stops at top position time in Auto mode.

(2) 02: the platform stops at bottom position time in Auto mode.

(3) 03: the platform stops at the bottom position time in Semi mode.

5. Operation description of the PC Board

5.1: Temp. setting    :press the key    in 3 sec.

temp. display shows ts

 

then press the key        once again (to release it once press immediately), the 

display showed the set temp., then you could adjust the keys     and    

 to input the needed temp. 

Summary of Contents for ST6

Page 1: ...XtraVac ST6 Shrink Tank Operation and Parts Manual XtraVac Packaging Machines 419 E 11th Ave North Kansas City MO 64116 USA ST6 Shrink Tank 1 800 728 2999 Sales XtraVac com 1 ...

Page 2: ...chine 1 Power requirement Voltage Look at the nameplate Current Look at the nameplate Frequency 50 60Hz Phase 3Ø 1 Maker sure the power is correct and the normal rated power is sufficient so you could connect the power to the machine 2 Fill the water to the maximum level please refer the line between the arrow marks at two sides of machine s body 3 Function description of the pushbuttons on the pa...

Page 3: ...MP DISPLAY 4 8 2 PROGRAM TIME DISPLAY 4 1 INCREASING KEY 4 2 REDUCING KEY PROGRAM TIME DISPLAY 4 3 4 4 TEMP SETTING KEY SEMI AUTO KEY TO PRESS IT WHEN MACHINE RUNS IN AUTO MODE 4 5 4 6 SEMI MODE STOP KEY START KEY 4 7 A S STOP START MAINTENANCE LIGHT HEATING LIGHT SEMI LIGHT AUTO LIGHT STOP LIGHT START LIGHT 4 8 Description of the Display 4 8 1 Temperature Display 4 8 1 1 Description of Temp Displ...

Page 4: ... 5 minutes 7 tA Temp Adjustment it is preset 0 4 8 2 Program and Time Display The left display is for program and the right display for time unit second 4 8 2 1 Description of Program display Program 1 01 the platform stops at top position time in Auto mode 2 02 the platform stops at bottom position time in Auto mode 3 03 the platform stops at the bottom position time in Semi mode 5 Operation desc...

Page 5: ...of for changing the program to release it once press immediately 5 3 After 30 seconds of the temp and program time setting it would keep into the memory of the program automatically 6 When you finish the work and would like to clean the tank please turn off the power No 2 and take off the platform fixing screw No 1 1 1 2 take off the platform from the machine Please watch out the water inside the ...

Page 6: ...ture above AH E1L thermocouple broken or current temperature below AL EAH if E1H keep displaying without reset til duration time of Ht EAL if E1L keep displaying without reset til duration time of Lt EOL cycle time alarm Example I set AH at 80 AL at 50 Ht at 3 Lt at 2 If current temperature 85 then screen will display E1H if E1H keep displaying more than 3 mins the screen will then display EAH If ...

Page 7: ...setting time For example it set 1002 cycles on this PC Board So the machine would stop when it runs to 1002 cycles and the display would appear EOL 1 EOL is on the left display It means the Motors needs to be changed the Lubricating Oil since the machine runs to 1002 cycles that we set on the PC Board 2 To Press the Increasing Key to clear the original setting time The right display would appear C...

Page 8: ...hanging the lubricant oil After finishing the cycles time setting pls put the Time Pressing Key again to complete the set up 4 For example this display means the cycle time is 3 201 002 In fact you could set the cycle time very big numbers so the machine would be not stopped when operation often Pls press this Temp setting key for the number dot moves forward to the next number when the right numb...

Page 9: ...800 728 2999 Sales XtraVac com 9 START STOP A S P 6 POWER LINE 7 WATER IN 8 WATER OUT 9 WATER OVERFLOW 10 TEMP SENSER 11 LIFT AND DOWN AXLE 12 MOTOR 13 LIMIT SWITCH 14 PRESSURE SWITCH 1 PLATFORM 1 1 PLATFORM DISMANTLE SCREW 1 2 PLATFORM DISMANTLE SCREW 2 MAIN SWITCH 3 MAIN SWITCH PROTECT HANDLE 4 CONTROL PANEL 5 1 HEATER 5 2 HEATER 5 3 HEATER ...

Page 10: ...om 10 XtraVac ST6 A Spare Parts List NO Description Part Number 1 Handle XVT464470 2 Spring Washer XVT72931 3 Hex Screw XVT76760 4 Knob XVT73757 5 Hex Nut XVT77271 6 Hex Nut XVT77271 7 Roller XVT73756 8 Shaft XVT77273 9 Inner Hex Screw XVT70988 10 Spring Washer XVT460653 11 Flat Washer XVT460654 12 Insert Bearing XVT73758 13 Hex Screw XVT77274 14 Spring Washer XVT70985 ...

Page 11: ...XtraVac ST6 Shrink Tank Operation and Parts Manual XtraVac Packaging Machines 419 E 11th Ave North Kansas City MO 64116 USA ST6 Shrink Tank 1 800 728 2999 Sales XtraVac com 11 ...

Page 12: ...276 28 Hex Nut XVT77312 5 Spring Washer XVT70985 29 Pressure Switch XVT467706 6 Inner Hex Screw XVT77277 30 Water pipe XVT99099 7 Shaft XVT77302 31 Ball valve XVT92230 8 Hex S headless Bolt XVT77303 32 Temperature staff XVT84936 9 Crank XVT77304 33 Bakelite plate Block XVT88527 10 Limit Switch XVT77305 11 Hex S headless Bolt XVT77303 12 Fixing Screw XVT77306 13 Sleeve XVT77307 14 Hex Nut XVT70831 ...

Page 13: ...XtraVac ST6 Shrink Tank Operation and Parts Manual XtraVac Packaging Machines 419 E 11th Ave North Kansas City MO 64116 USA ST6 Shrink Tank 1 800 728 2999 Sales XtraVac com 13 XtraVac ST6 C ...

Page 14: ... City MO 64116 USA ST6 Shrink Tank 1 800 728 2999 Sales XtraVac com 14 Spare Parts List NO Description Part Number 1 Round Head Screw XVT458060 2 Front Panel XVT76117 3 PC Board XVT76116 4 Main Switch XVT73759 5 Hex Screw XVT75412 6 Spring Washer XVT70985 7 Handle XVT77313 8 Stainless Steel Plate XVT469351 ...

Page 15: ...XtraVac ST6 Shrink Tank Operation and Parts Manual XtraVac Packaging Machines 419 E 11th Ave North Kansas City MO 64116 USA ST6 Shrink Tank 1 800 728 2999 Sales XtraVac com 15 ...

Page 16: ...arts List Description Part Number 1 Control box XVT464041 2 Gland XVT466372 3 Contactor XVT46480 4 Contactor XVT468607 5 No fuse breaker XVT71327 6 Overload Relay XVT71328 7 Terminal block green XVT99447 8 Terminal block XVT70983 9 Fuse holder XVT71015 10 Fuse 2A XVT71287 11 Fuse holder 1P XVT71329 12 Fuse 2A XVT99449 13 Fuse holder 32A XVT99448 14 Fuse 32A XVT87260 15 Control box cover XVT467521 ...

Page 17: ...XtraVac ST6 Shrink Tank Operation and Parts Manual XtraVac Packaging Machines 419 E 11th Ave North Kansas City MO 64116 USA ST6 Shrink Tank 1 800 728 2999 Sales XtraVac com 17 ...

Page 18: ...ED PROCESSED NAME DATE Power circuit diagram PAGE JAW FENG MACHINERY CO LTD E D C B A E D C B A L1 L2 L3 LS1 TOP SENSOR LS2 BOTTON SENSOR MC1 CONTACTOR OF TEMPERATURE MC2 CONTACTOR OF MOTOR L N M MC2 MC1 A C RL Y3 RL RL Y2 Y1 S1 G WHITE BLACK temperature senor 2 MC1 4 TR Y MC2 1 pressure switch CF 01 G D C 5 6 7 5 NO NO LS1 LS2 TR Y Heater 3 FUSE 32A SWITCH 64A NO FUSE BREAKER 40A FUSE 2A ...

Reviews: