XtraVac ST6 Shrink Tank Operation and Parts Manual
XtraVac Packaging Machines
419 E. 11
th
Ave North Kansas City, MO 64116 USA
ST6 Shrink Tank
+1 (800) 728-2999 [email protected]
4
(1) ts: Temp. Setting: It is preset 85
℃
(2) td: Temp. Difference setting: it is preset 1
℃
(3) AH: High Temp. Alarm setting: it is preset 99
℃
(4) AL: Low Temp. Alarm setting: it is preset 40
℃
(5) Ht: High temp. Alarm Time Setting: it is preset 1minute.
(6) Lt: Low temp. Alarm Time Setting: it is preset 5 minutes.
(7) tA: Temp. Adjustment: it is preset 0
4.8.2: Program and Time Display:
The left display is for program and the right display for time (unit:
second)
4.8.2.1: Description of Program display:
Program:
(1) 01: the platform stops at top position time in Auto mode.
(2) 02: the platform stops at bottom position time in Auto mode.
(3) 03: the platform stops at the bottom position time in Semi mode.
5. Operation description of the PC Board
5.1: Temp. setting :press the key in 3 sec.
,
temp. display shows ts
,
then press the key once again (to release it once press immediately), the
display showed the set temp., then you could adjust the keys and
to input the needed temp.