PROBLEM SOLVING
If not in use, the tool shall be placed in the stand holder.
It is strictly prohibitedto keep the tool ON when unattended.
1. Use the tool with caution to prevent a fire.
2. Change the accessories only having the tool turned OFF and disconnecting from the power supply.
3. Use protective gloves when changing the accessories.
4. Hot parts of the tool shall be kept away from flammable objects.
5. Do not operate the tool when in areas with aggressive gases,flammable liquids and explosives.
6. Disconnect the cord from the power supply after finishing the operation.
7. After your operating, place the tool in the stand holder and let cool.
8. Heat may get in contact with materials which may be out of sight, be careful!
9. The welding process shall not be repeated on the material joint if resulting in an exposure of parts under
voltage. The thermoplastic pipe welder parts using low voltage exceeding 12V are considered under voltage as
well.
10. Repairs shall be carried out by authorized individuals only.
Prior to operation
Rotate the regulation button (7) to set the welding temperature (Fig.1). The proper temperature shall be set
according to standards of the material producer.
1. Place the tool to the stand holder. Mount the proper matrix according to an appropriate specification. Tighten
the matrix with the wrench, smaller sizes are typically found in the fron part.
2. Start the tool (Be aware: the power source shall be grounded). The green indicator ensures proper power
connection. Turn the switch into the requested position, 1 to 3 (see Table 2). The red indicator shows the
tool heating up. After reaching the operating temperature (set by the switch – thermostat, the red indicator turns
off), you may initiate your work. The red indicator turns on again after a temperature decrease and restarts the
heating of the tool.
3. Cut the pipe. Insert the pipe or armature into the matrix for a short period of time (see Table 1), quickly
remove and then insert again. Do not screw tightly up to the requested depth.
4. After finishing your operation, disconnect the cord from the power supply and let the cool down.
5. The joint shall not be pressured until a two-hour period!
Warning !
When inserting the pipe, it is not allowed to twist the pipe (apply the axial pressure only).
extension warm-up time
cooling time
melting
depth
Note: It is necessary to extend the heating time by
50% when the temperature decreases under 5°C.
The principle of polyfusion welding:
The following description does not substitute valid standards and qualified personnel training and serves to
information purpose only!