54
5) Action link
You can set the function such as "None", "Preset", "Sequence" and "Auto pan".
This function will be working when detected alarm-input
(In case of the Sequence, "Preset No" means group number)
4.12.2 Alarm Out
1) Alarm Output
Select alarm output 'Enable' or 'Disable'.
2) Linkage
None : Alarm output function doesn't operate relating alarm input or motion event.
Alarm input : Alarm output function operates only by alarm input event.
Motion : Alarm output function operates only by motion event.
Alarm input + Motion : Alarm output function operates by both alarm input
and motion event
3) Duration Time
Set duration time upon alarm events.
4) Test on
Alarm output is activated by compulsion and you can check the action internally.
5) Test off
Alarm action will be terminated.
Click '
' button to save.
-Alarm input is the same meaning with sensor or sensor input.
-Alarm output is the same meaning with relay.
-Alarm event is the same meaning with alarm input or motion event.
Summary of Contents for XL-ICA-661M1CP
Page 1: ...XL ICA 661M1CP NETWORK PAN TILT DOME CAMERA USER MANUAL ...
Page 2: ...2 ...
Page 6: ...6 Chapter 8 Troubleshooting 76 ...
Page 8: ...8 Chapter 1 Package 1 1 Camera Features 9 1 2 Package 9 1 3 How To Install 10 Specification ...
Page 11: ...11 1 3 2 Dimension 1 3 3 Reset Button Factory Reset switch ...
Page 15: ...15 Chapter 2 Installation and Video Check 2 1 Installation 16 2 2 Video Check 17 ...
Page 20: ...20 Pic 2 5 ActiveX Download ...
Page 61: ...61 Chapter 5 IP Finder Use of IP finder ...
Page 65: ...65 Pic 5 5 Ping ...
Page 66: ...66 Chapter 6 Basic Network 6 1 Public IP 68 6 2 Private IP 69 6 3 Ping test 70 ...
Page 70: ...70 Ping Failure Ping Success ...
Page 75: ...75 Chapter 8 Troubleshooting ...