background image

                                                                           

 

 

15

3

 

Installation  

This series IPC can be put on the table to realize surveillance. Or you can use the bracket or the in-
ceiling installation to realize the hang function. Please refer to the steps listed below.  
 

3.1

 

Device Installation  

Step 1 

Use the inner hexagonal wrench (provided) to loose the three inner hexagon screws in the dome cover 
and then open the cover. The device is shown as in Figure 3-1 

 

Figure 3-1 

 

Step 2 

Use the inner hexagonal wrench (provided) to loose the three inner hexagon screws in the dome and 
then remove the device pedestal. See 

Figure 3-2

  . 

 

With IR light                                       Without IR light  

Figure 3-2 

Summary of Contents for XL-ICA-206M3

Page 1: ...XL ICA 206M3 IP camera IPC User s manual ...

Page 2: ... our IP camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this user s manual well for future reference ...

Page 3: ...ified engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Environment This series IP camera should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc Please keep it away from the electromagnetic radiation o...

Page 4: ... put the dustproof cap to protect the CCD CMOS component when you do not use the camera 7 Accessories Be sure to use all the accessories recommended by manufacturer Before installation please open the package and check all the components are included Contact your local retailer ASAP if something is broken in your package Accessory Name Amount IPC Unit 1 MD9M data converter cable 1 Accessories bag ...

Page 5: ...ion Combination Cable 11 2 2 Framework and Dimension 12 2 3 Bidirectional talk 13 2 3 1 Device Connection 13 2 3 2 Operation 13 2 4 Alarm Setup 13 3 Installation 15 3 1 Device Installation 15 3 2 SD Card Installation 18 3 3 Lens Adjustment 18 4 Quick Configuration Tool 20 4 1 Overview 20 4 2 Operation 20 5 Web Operation 23 5 1 Network Connection 23 5 2 Login and Main Interface 23 ...

Page 6: ...v 6 FAQ 26 Appendix Toxic or Hazardous Materials or Elements 27 ...

Page 7: ... backup function in accordance with your configuration and setup in alarm or schedule setting z Support record via Web and the recorded file are storage in the client end PC z Support built in SD card z Support local SD card hot swap support short time storage when encounter disconnection Alarm Function z Real time respond to external local alarm input and video detect as user pre defined activati...

Page 8: ... inch CMOS 1 3 inch CCD Pixel 2048 H 1536 V 1280 H 960 V Day Night Mode Support day night mode switch and IR CUT at the same time Auto Iris DC drive Gain Control Fixed Auto White Balance Manual Auto BLC Manual Auto Electronic Shutter Manual Auto PAL It ranges from 1 3 to 1 10000 NTSC It ranges from 1 4 to 1 10000 Manual Auto PAL It ranges from 1 3 to 1 100000 NTSC It ranges from 1 4 to 1 100000 Vi...

Page 9: ...hannel input 1 channel output Record Priority Manual External alarm Video detect Schedule Record and Backup Local Storage Support Micro SD card storage Wire Network 1 channel wire Ethernet port 10 100 Base T Ethernet Network Protocol Standard HTTP TCP IP IPv4 IPv6 ARP IGMP ICMP RTSP RTP UDP SMTP FTP DHCP DNS DDNS PPPOE UPNP NTP Bonjour SNMP NFS Network Remote Operation Monitor system setup file do...

Page 10: ...eral Encode mode H 264B Resolution 1080P 1920 1080 720P 1280 72 0 Frame rate FPS PAL 25 NTSC 30 Bit stream type CBR Reference bit rate 3584 8192 Kb S Bit rate 8192 I frame interval 50 Watermark settings Enable Main stream Watermark character DigitalCCTV Enable Enable Bit stream type General Encode mode H 264B Resolution CIF 352 288 35 2 240 CIF 352 288 3 52 240 Frame rate FPS PAL 25 NTSC 30 Bit ra...

Page 11: ... path C PictureDownload Path Record path C RecordDownload Enable Enable Main stream Encode mode G 711A Enable Disable Audio Sub Extra stream Encode mode G 711A Host name IPC Ethernet card Wire Default Mode Static MAC address Depends on the device IP version IPV4 IP address 192 168 1 168 Subnet mask 255 255 255 0 Default gateway 192 168 1 1 Preferred DNS 8 8 8 8 Alternate DNS 8 8 8 8 TCP IP Enable ...

Page 12: ...er name none Password N A DDNS Update period 5m IP filter Trusted sites Disable SMTP server none Port 25 Anonymity Disable User name anonymity Password N A Sender none Authenticatio n Encrypt mode N A Title Subject IPC Message Main Receiver N A Interval 0s SMTP email Health email Disable interval 60m UPnP Enable UPnP Disable SNMP v1 Disable SNMP v2 Disable SNMP port 161 Read community public Write...

Page 13: ... device ID none WIFI On Enable Enable Real time monitor 0 QoS Command 0 Enable Disable Anti dither 5 seconds Sensitivity 3 Record Channel Enable Record Delay 10 seconds Relay Alarm output Enable Alarm delay 10s Send email Disable PTZ Disable Activation N A Address 0 Motion detect Snapshot Disable Enable Disable Record Channel Enable Record Delay 10 seconds Relay out Enable Record Delay 10 seconds ...

Page 14: ...tput Enable Relay Alarm delay 10s Send email Disable PTZ Disable Activation N A Address 0 Relay Alarm activation Snapshot Disable Alarm setup Relay Alarm output 1 Enable Disable Relay Alarm output Enable Relay output delay 10s No SD card Send email Disable Enable Disable Capacity limit Space threshold 10 Relay Alarm output Enable Relay output delay 10s Capacity warning Send email Disable Enable Di...

Page 15: ... Enable Record delay 10s Relay Alarm output Enable IP conflict Relay output delay 10s FTP enable Disable Server IP N A Port 21 User name anonymity Password N A Remote storage path share FT P Emergency storage to local path Disable NAS enable Disable Mode NFS Server IP N A Port 21 User name N A Password N A Destination Storag e Network storage Remote storage path N A Pack duration 8m Pre record 5s ...

Page 16: ... GMT 08 00 Current time Sync PC DST Disable DTS type Week Start time 00 00 00 of the first Sunday of the month End time 00 00 00 of the second Monday of the month Synchronize with NTP Disable NTP server clock isc org Port 37 General setup Date and time Update period 10m Protocol PELCOD Address 1 Baud rate 9600 Data bit 8 Stop bit 1 PTZ setup Parity N A Auto reboot Enable System management Auto mai...

Page 17: ...udio signal It can receive the analog audio signal from the pickup AUDIO OUT Audio output port RCA Output audio signal to the devices such as the sound box 12V DC AC24V Power input port Power port Input DC 12V AC 24V I O I O cable port Connect to I O port cable LAN Network port Ethernet port z Connect to standard Ethernet cable z Support PoE Please refer to the follow sheet for detailed informatio...

Page 18: ...ut port It works with the ALARM_COM port Blue RESET It is to restore factory default setup When the device is working properly please connect the blue cable restore default setup port to the orange cable GND signal for 5 seconds the device can resume factory default setup Orange GND Ground port 2 2 Framework and Dimension Please refer to the following two figures for dimension information The unit...

Page 19: ...nal talk 2 4 Alarm Setup The alarm interface is shown as in Figure 2 4 Please follow the steps listed below for local alarm input and output connection 1 Connect the alarm input device to the alarm input port grey or brown pin of I O port cable 2 Connect the alarm output device to the alarm output port White pin and alarm output public port Red pin The alarm output port supports NO normal open ala...

Page 20: ...14 Figure 2 4 ...

Page 21: ...ed below 3 1 Device Installation Step 1 Use the inner hexagonal wrench provided to loose the three inner hexagon screws in the dome cover and then open the cover The device is shown as in Figure 3 1 Figure 3 1 Step 2 Use the inner hexagonal wrench provided to loose the three inner hexagon screws in the dome and then remove the device pedestal See Figure 3 2 With IR light Without IR light Figure 3 ...

Page 22: ...three holes of the installation position Put the three inner hexagon screws into the screw holes at the bottom of the pedestal Use the inner hexagon screwdriver to fix firmly Connect the GND to the ground wires to improve stability See Figure 3 3 With IR light Without IR light Figure 3 3 Step 6 Adjust the X Y Z axis module to turn the device to the proper monitor angle Please follow the steps list...

Page 23: ...figure are the optical adjustment component Please make sure it is outward and do not allow it to touch the X Y Z axis module See Figure 3 5 Figure 3 5 Step 7 Put the dome cover back and then put the three inner hexagon screws into the holes of the device Use the inner hexagonal wrench to fasten these three screws See Figure 3 6 Figure 3 6 ...

Page 24: ...IR light Figure 3 7 3 3 Lens Adjustment Step 1 Slightly loose the screw B manually and then turn the screw B slowly Adjust the lens focus distance to the proper position according to the monitor video See Figure 3 8 Step 2 Use the flat screwdriver to loose the screw A slightly and then turn the Screw A slowly Adjust the lens focus to get the clear video and then use the flat screwdriver to secure ...

Page 25: ...19 With IR light Without IR light Figure 3 8 ...

Page 26: ...ly applies to the IP addresses in the same segment 4 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 4 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc Figure 4 1 Select one IP address and then right click mouse you can see an interface is shown as in Figure 4 2 Figure 4 2 ...

Page 27: ...nterface Or you can select an IP address and then click the Login button to go to the login interface See Figure 4 4 In Figure 4 4 you can view device IP address user name password and port Please modify the corresponding information to login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you can not login the dev...

Page 28: ...22 Figure 4 5 ...

Page 29: ...sk and gateway of the PC and the IPC respectively IPC default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 z Use order ping IP camera address to check connection is OK or not 5 2 Login and Main Interface Open IE and input IP camera address in the address bar For example if your camera IP is 192 168 1 108 then please input http 192 168 1 108 in IE address bar See ...

Page 30: ...ase click OK button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have installed the plug in to disable the control download Or you can lower the IE security level See Figure 5 3 Figure 5 3 After you logged in you can see the main window See Figure 5 4 ...

Page 31: ...25 Figure 5 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction ...

Page 32: ... network When network upgrade operation failed you can use port 3800 to continue upgrade Recommended SD card brand Kingston 4GB Kingston 1GB Kingston 16GB Transcend 16GB SanDisk 1G SanDisk 4G Usually we recommend the 4GB or higher or industry level high speed card in case the slow speed results in data loss Audio function Please use active device for the audio monitor input otherwise there is no a...

Page 33: ...the environmental friendly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding lo...