background image

                                                                           

 

 

1

1

 

Structure  

1.1

 

Components 

You can refer to the following figure for

 multiple-function combination cable

 information. See Figure 

1-1

 

Figure 1-1 

Please refer to the following sheet for detailed information. 
 
 
 
 
 
 
 

Port Name  

Function 

Note 

Port 4 

Network port  

Connect to standard Ethernet cable.  

Port 5 

DC 12V 
power  

Power input port. Input DC 12V. 

 

1.2

 

Framework and Dimension 

Component  

Component Name 

Component 1 

Device lens  

Component 2 

Dome body  

Component 3 

Dome enclosure  

Summary of Contents for XL-ICA-206M1IR

Page 1: ...Quick Start Guide Version 1 0 0 XL ICA 206M1IR ...

Page 2: ...r installation We are not liable for any problems caused by unauthorized modification or attempted repair 2 Transportation security Heavy stress violent vibration or water splash are not allowed during transportation storage and installation 3 Installation Do not apply power to the camera before completing installation Please install the proper power cut off device during the installation connecti...

Page 3: ... use the dry soft cloth to clean the device If there is too much dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device Please put the dustproof cap to protect the CCD CMOS component when you do not use the camera 7 Accessories Be sure to use all the accessories recommended by manufacturer Before installation p...

Page 4: ...2 Device Installation 3 2 1 Installation Steps 3 2 2 Restore Factory Default Setup Introduction 5 3 Quick Configuration Tool 6 3 1 Overview 6 3 2 Operation 6 4 Web Operation 9 4 1 Network Connection 9 4 2 Login and Logout 9 5 FAQ 12 Appendix Toxic or Hazardous Materials or Elements 13 ...

Page 5: ... 1 1 Figure 1 1 Please refer to the following sheet for detailed information Port Name Function Note Port 4 Network port Connect to standard Ethernet cable Port 5 DC 12V power Power input port Input DC 12V 1 2 Framework and Dimension Component Component Name Component 1 Device lens Component 2 Dome body Component 3 Dome enclosure ...

Page 6: ...2 Please refer to the following two figures for dimension information The unit is mm See Figure 1 2 and Figure 1 3 Figure 1 2 Figure 1 3 ...

Page 7: ...nstall the device Step 3 Adjust the device installation pedestal to the proper position and then line up the three screw holes in the device pedestal to the three plastic expansion bolt holes in the installation position Put the three self tapping screws in the three plastic expansion bolts firmly Loosen the M3X8 cross recessed pan head slot screw of the pedestal to unfasten the preforming Do not ...

Page 8: ...the other is from the side Please refer to the following figure for cable exit from the side information Figure 2 3 Please earth the GND port of the device to enhance the device reliability The GND port is near the cable exit port on the rear of the dome The GND screw uses the M2X5 pan screw ...

Page 9: ...the gland cover Step2 Take the dome body out and then turn the top cover hard to remove Step3 Slightly press the RESET button to complete the reset function See Figure 2 5 Step4 Turn the top cover back to the original position Please make sure it reaches the original position otherwise it may result in water leakage Step5 Put the dome back to the gland cover Please refer to step4 in chapter 2 1 to...

Page 10: ... MAC address and etc Figure 3 1 Select one IP address and then right click mouse you can see an interface is shown as in Figure 3 2 Note You can set the IP address subnet mask and gateway for the IPC and PC Please note IPC IP address and PC IP address shall be in the same network segment if there is no router IPC default IP address is 192 168 1 108 If there is a router please set the corresponding...

Page 11: ... IP address and then double click it to open the login interface Or you can select an IP address and then click the Login button to go to the login interface See Figure 3 4 In Figure 3 4 you can view device IP address user name password and port Please modify the corresponding information to login Please note the port information here shall be identical with the port value you set in TCP port in W...

Page 12: ...guration tool main interface is shown as below See Figure 3 5 Figure 3 5 For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD ...

Page 13: ... IPC default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 z Use order ping IP camera address to check connection is OK or not 4 2 Login and Logout Open IE and input IP camera address in the address bar For example if your camera IP is 192 168 1 108 then please input http 192 168 1 108 in IE address bar See Figure 4 1 Figure 4 1 The login interface is shown as bel...

Page 14: ...ase click OK button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have installed the plug in to disable the control download Or you can lower the IE security level See Figure 4 3 Figure 4 3 After you logged in you can see the main window See Figure 4 4 ...

Page 15: ...11 Figure 4 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction ...

Page 16: ...er if you can not install the client end or can not view after the installation We recommend the win2000sp4 OS or install the client end of the low version The Active X control is blocked The display card version shall be dx8 1 or higher Network connection error occurred Invalid network setup Invalid user name or password I can not play the download file There is no player There is no DX8 1 or hig...

Page 17: ...s substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your local government statutes ...

Reviews: