background image

2.3 Alarm Function

 

 

 

 

This product can be connected to up to 8 channels alarm with 1st channel as SOS button, 

2nd channel as gas alarm, 3rd channel as smoke alarm while the remaining 5 channels can be 

flexibly set. 

Under  sub-menu  there is information  of  protection zone  status, alarm  records  and mode 

setup. 

 

 

2.3.1 Protection Zone Status Function

 

 

 

This device mainly displays information of protection zone type, current status, and delay 

time for the 8 protection zones. Users may enter setup interface of protection zone by clicking 

setup button (password required), and can set contents such as protection zone type, NO/NC, 

alarm type, enter delay, exit delay. For 1

st 

to 3

rd 

channels  therein, users can only set NO/NC 

type; for the remaining 5 channels, users can set all, while protection zone types consist of IR, 

gas, smoke, SOS, door sensor, theft alarm, tripwire. Enter and exit time can be set to 0s, 10s, 

30s, 60s, 90s and 120s. Delay is available only with delay alarm setup. 

Users can make bypass and delete each protection zone, or make the selected protection 

zone invalid once or for longer period. 

 

 

2.3.2 Alarm Recording Function

 

 

 

Alarm  recording  mainly  records  information  of  the  time  alarm  happens,  protection  zone 

NO.,  alarm  processed  or  not.  The  alarm  info  will  be  updated  to  management  platform 

synchronously. 

When alarm happens in any protection zone, there will be a 15s beep locally with alarm 

interface pops up. 

 

 

2.3.3 Mode Setup

 

 

 

Alarm of this product consists of away mode, in mode, sleep mode, and user mode. You 

may set each mode to on/off separately for each protection zone. Default setup are as follows: 

Away mode: 1-8 channels all on; 

In mode: 1-3 channels on, others off; 

Sleep mode: 1-5 channels on, others off; 

User mode: all off. 

 

 

2.4 Info Search Function

 

 

 

After VDP receives messages  (announcement)  sent  from  platform,  light  turns  on. Under 

“info search” click “announcement”, you may view announcements ranked by title and time. If 
you  select  one  announcement  and  click  search,  you  may  view  details  of  the  selected 

announcement. 

Summary of Contents for DPM-IP70 TMD Series

Page 1: ...DPM IP70xTMD Monitors for IP videodoor system User s manual...

Page 2: ...with VDP 7 2 2 4 Monitoring Function 7 2 2 5 Call Record Function 7 2 2 6 Contacts 7 2 3 Alarm Function 8 2 3 1 Protection Zone Status Function 8 2 3 2 Alarm Recording Function 8 2 3 3 Mode Setup 8 2...

Page 3: ...per handling or installation We are not liable for any problems caused by unauthorized modifications or attempted repair The device should be installed in a cool dry place away from direct sunlight in...

Page 4: ...hang it up 4 Monitor Monitor door station video 5 Unlock Press this button during incoming call calling and monitoring you can unlock corresponding door station Chart 1 1 1 3 Indicator The indicators...

Page 5: ...VDP VDP will ring and display video from door station You may press call button or answer icon to answer call and achieve bidirectional talk with the door station While VDP is displaying video from do...

Page 6: ...l save delete or delete all callers 2 2 6 Contacts Under video bidirectional talk status click call resident you may enter contacts by clicking contacts icon on the right of call box The interface inc...

Page 7: ...and 120s Delay is available only with delay alarm setup Users can make bypass and delete each protection zone or make the selected protection zone invalid once or for longer period 2 3 2 Alarm Recordi...

Page 8: ...setup select from 0 hour 0H 1 hour 1H 2 hours 2H 4 hours 4H 8 hours 8H and 24 hours 24H to block out local ring 6 Restore default settings restore all user settings to default 7 Touch screen sound but...

Page 9: ...password for disarming If you input correct password the system will disarm if you input incorrect password you will see a message saying incorrect password please try again 2 8 Screen Calibration Fun...

Page 10: ...echnology Alarm Alarm Input Support 8 channels alarm input Network Ethernet 10M 100Mbps self fit Networking Protocol TCP IP Specifications Power DC 10 15V or AV direct feed Power Consumption Standby 1...

Page 11: ...ical Please see Chart 4 1 No Name Description 1 Alarm Interface 8 ch alarm please see tag for details 2 Communication Port May directly connect to network cable or via corridor exchanger 3 Handset Int...

Page 12: ...or failure please do not try to dismount or fix it by yourself and please contact after sales department for assistance Please refer to Figure 5 1 as guide Q The screen on VDP is black and the indica...

Reviews: