•  On main menu page,touch " Manual Monitor" icon to open monitor page. Input the address 

of door station by touching digital keypad on guard unit, for example,to monitor the 1st 

door station of B block.you should input B-1.then touch "Monitor" icon to monitor.(during 

inputing,press " * " key to cancel)

•  Monitoring door station or common door station by list is also available.on monitor 

page,press "list" icon, touch one item,then touch "monitor" icon to see conditions of door 

station.

•  If the number is correct, monitoring is activated immediately when the door station is free. 

During monitoring,press "unlock" icon to release the door.

•  The system will cut off automatically if exceeds maximum monitor time.

•  On main menu page of the Guard Unit,touch " Event->Alarm record"to enter alarm record 

page,the latest record will be shown on first item.

•  All alarm records ,the current record ,the alarm type, alarm time and the address of monitor 

will be displayed .

•  If the system has no alarm records,it will show "have no record !".

•  Press "Page Up" to see last page alarm records,and press "Page Dn" to see next page alarm 

records.

•  Press one of alarm record item to enter alarm status page, then press "Dial" icon to call the 

User alarms to Guard Unit

Entrance monitoring

Checking alarm records for monitor

•  Select "Call Guard Unit" on monitor to alarm guard unit.(please refer to monitor user manual 

for more detail information)

•  The Guard Unit will send out a soud of buzzer and the alarm button will flash in red when 

receives alarm signal. At the same time, the address of the monitor will be shown on screen.

The latest alarm record will be displayed on first item.

•  Press one of alarm record to enter alarm status page,the buzzer will stop ringing,and the 

alarm indicator will stop flash.

•  At alarm status page,press "dial" icon to call back the current monitor.

•  If the user answers the call,the guard person can talk with the user immediately.

•  The system will cut off automatically if exceeds the maximum calling waiting time in calling 

state or exceeds maximum talking time in talking state.

Summary of Contents for DPG-IP-G21

Page 1: ...English USER MANUAL DPG IP G21...

Page 2: ...es alarm record LED Indicator 1 Red indicator flash first green indicator flash later when power on 2 Blue indicator ormally on when work in normal 3 Blue indicator flash when in calling state 4 Red i...

Page 3: ...Vp p 75 CCIR standard Wiring CAT5 cable Dimension 220 H x 358 W x 35 D mm Answer calls from door station Input 0000 on door station to call guard unit The Guard Unit rings and the red LED indicator fl...

Page 4: ...Unit for example to call the 1st door station of B block you should input B 1 then touch dial icon to activate the calling during inputting press key to cancel Calling door station or common door stat...

Page 5: ...displayed If the system has no alarm records it will show have no record Press Page Up to see last page alarm records and press Page Dn to see next page alarm records Press one of alarm record item t...

Page 6: ...n menu page of Guard Unit touch Event Missed calls all calls that has not been answered will be shown Touch Event All calls all calling records the latest calling record the call type call time and th...

Page 7: ...set to DD MM YY or MM DD YY touch Date Format icon to switch date format setting The time format can be set to 24 hours or 12 hours format touch Time Format icon to switch time format setting To see t...

Page 8: ...ecording are available and auto recording is default If receive a call after a moment the guard unit will record automatically one picture will be taken for each calling or you can touch Capture icon...

Page 9: ...ease increase the value The Scene mode selection Total 4 screen modes can be selected in sequence Normal User Soft and Bright Whenever you modify Brightness or colour Scene item will be set to User mo...

Reviews: