-6-
Unlock parameter setting(set in monitor)
monitor
intercom
setup
exit
Outdoor Tone -- 01
Intercom Tone -- 05
Monitor Time -- 1min
Advanced Set...
Auto Record -- OFF
Exit
0
* * *
Password:
Slave Addr Set -- 0
Guard Unit Set -- 0
Date/Time Set...
Other Settings...
Information...
Exit
Hardware ver 0302
Software ver 0168
Voltage 22.4V
Manufacture 00.0T
Restore to default
Exit
Unlock Time 1
Unlock Mode 0
Exit
1.Press
setup
setup item on
main menu page.
2.Select Advanced Set...item
a password will be asked.
4.Select Information...item
Note:
1.must•connect• DPC •correctly•before•setting.
2.the•parameter•will•be•saved•in• DPC •automatically,so•you•need•only•set•on•one•monitor.
3.the•above•cutline•is•fit•for•some•series•monitors•only
•
• • •
•
•
5.Press UNLOCK button
and hold for 2s.
6.Setting unlock mode to 0 or 1
3.The default password is 2008.
LOCK
BUS
PL
S1
+
S2
+
S-
Take off the Jumper
POWER
SUPPLY
LOCK
BUS
PL
S1
+
S2
+
S-
Take off the Jumper
POWER
SUPPLY
LOCK
connect•one•lock
connect•two•locks