Table 2.1(Parameters):

 

 

 

Item

 

 

Description

 

Factory 

set

 

Monitor Timing

 

To show the monitor time,Range from 6s to 600s

 

30s

 

 

Switch Timing

 

To show the surveillance time for each Door Station or 
CCTV camera.Range from 6s to 600s

 

 

40s

 

Wait Timing

 

To show the calling wait time,Rang from 10s to 600s

 

30s

 

 

Talk Timing

 

To show the limitation time of talking,Range from 10s 

 

to 600s

 

 

90s

 

 

Monitor & Speack

 

To enable Indoor Monitor under monitoring state can 
speak to Door Station at same time. If set to 1, talk 
enabled; set to 0, disabled. 

 

 

 

 
 

Monitor & Unlock

 

To enable Monitors under monitoring state can open 
the door at the same time.If set to 0, unlock function 
is disabled; Set to 1, unlock is enable;Set to 2,unlock 
is enable and close at once;Set to 3,unlock is enable 
and close in 5s.

 

 

 
 

[1]

 

 

Ring Numbers

 

To  show  ring  times  when  door  station  calls  monitor.4 
options for choice. If set to 0, ring once. If set to 1,ring 
twice. If set to 2, ring three times.If set to 3,cycle ring

 

 

[1]

 

 

NameList Display 
Mode

 

To  show  the  namelist  display  mode.If  set  to  0,it's  the 
DT-Config  display  mode.If  set  to  1,it's  the  Simulate 
display mode

 

 

[0]

 

 

Working Mode

 

To show the working mode.If set to 0,it's the apartment 

 

system mode.If set to 1,it's the villa mode.

 

 

[0]

 

 

 

Note:

 this section is set on DT-Config software, for more detail informations, please refer to the 

DT-Config software user instructions.

 

Summary of Contents for DPC-D218ID

Page 1: ...DPC D218ID Door Stat ion User Manual RF CARD 1 2 3 4 5 6 7 8 9 0...

Page 2: ...RD 3 2 1 J KMB JP LK 1 2 3 4 5 6 7 8 9 0 12V 12VDC power output LK GND power ground LK COM common contact of the Relay NO normally open contact of the Relay refer to 2 wire technical guide for Lock co...

Page 3: ...ainy cover after mounted 3 Camera angle Adjust the camera angle and attach the metal to the panel and wire correctly 4 Attach screws to fix the metal box 5 Attach the unit to the rainy cover correctly...

Page 4: ...ition for Power to Unlock safety type Normally open mode set to 2 3 position for Power off to Unlock type Normally closed mode Note that the unlock relay mode is set on the Parameter tab of DT CONFIG...

Page 5: ...Parameter tab of DT CONFIG software If different unlocking time is needed to be configured please use the DT CONFIG software to change the setting on the Parameter tab see the program section C Conne...

Page 6: ...S t a t e 0 Re d i a l R F C A R D 1 2 3 1 To o l s 4 5 6 7 8 9 0 9 0 0 8 2 E x i t s Please Input Password When Door Station is in standby press key input 9008 then input the Admin Code 66666666 by...

Page 7: ...8 4 Unlock Code 1111 5 Display Mode 6 Clock 7 Setup Code 8 About 9 Default 3 Card Manage 1 Add Card 2 Delete By Card 3 Delete By M code 4 Cards Information 5 Format 4 Online Monitors To search the onl...

Page 8: ...ocation If set to 0 the card is saved in door station If set to 1 the card is saved in DPA D2 IPC 0 Doorplate Mode To set the calling mode If set to 0 it s the auto mode that means the calling will be...

Page 9: ...te can open the door at the same time If set to 0 unlock function is disabled Set to 1 unlock is enable Set to 2 unlock is enable and close at once Set to 3 unlock is enable and close in 5s 1 Ring Num...

Page 10: ...e format is MM DD YY Time format if set to 0 time format is 24 hour standard If set to 1 time format is12 hour standard Setup Code To change the Program Code 88888888 About 1 Hardware version To show...

Page 11: ...page to call the desired flat Residents can open the door by using their unique Unlock Code four digit PIN code If the door station is in standby mode press key then input the four digit unlock to ope...

Page 12: ...9 D e f a u l t Please Input Password Back Save Input Installer code 66666666 by default then press to save 6 Change Ring Tone There are 12 different ringtones If door station runs as Debug State you...

Page 13: ...o l s 3 C a r d M e m o r y 5 D o o r p l a t e M o d e Press1 9 6 A u d i o O p t i o n s Pres NO 4 O n l i n e M o n i t o r s to select 7 P a ra m e t e r s 2 E x i t s to select Back 5 O n l i n e...

Page 14: ...ss to update 10 User Card Management This section explains how to configure the key fob function on DPC D218 The key fob is used to open the lock Total 1000 key fobs can be registered with one door st...

Page 15: ...he unwanted card s when the Door station is in Delete Card Mode 2 Delete by room number delete all the registered User Cards related to that room number Delete By Card In Debug State Press 1 3 Card Ma...

Page 16: ...lease Input Password Back Save 11 Change Door Station Language It s convenient to change the user interface for DPC D218 Just put the config files to the SD card and by means of the digital keypad of...

Page 17: ...lish 8113 Russian 8114 Slovakia 8115 Hungary 8116 Czech When the door station output a long sound DI that means UI updating is finished 12 Search online door stations and monitors Online Search is a v...

Page 18: ...ist function DPC D218 is designed to have digital keypad and big TFT screen Its namelist was shown on the screen and customer can do the calling operation through the digital keypad guided by Namelist...

Page 19: ...r supply DC24V Powered by DPA D2A Camera Lens 1 4 ACS 4T image sensor with DSP processor Power consumption Standby 3W Working status 9W Screen 3 5 inch TFT Resolution 320 R G B X240 pixels Video signa...

Reviews: