DIP1
DIP2
DIP3
Door station address
OFF
OFF
OFF
Only one door station, set to 000
ON
OFF
OFF
Multi door station, first one address
OFF
ON
OFF
Multi door station, second one address
ON
ON
OFF
Multi door station, third one address
OFF
OFF
ON
Multi door station, fourth one address
ON
OFF
ON
Multi door station, fifth one address
OFF
ON
ON
Multi door station, sixth one address
ON
ON
ON
Multi door station, seventh one address
4. DIP Switches settings
Total 6 bits in the DIP switches can be configured. The switches can be modified either before or
after installation, but restart the power supply is needed whenever the switches have been
modified.
DIP1
DIP2
DIP3
The first three bit for door station ID settings
When multi-door stations are installed in the system, these three bit must be set
correctly, the door station’s DIP should set as below , If only one door station is
installed , set to 000.
The details as below:
DIP4
DIP4: button code selection
DIP4=OFF=chose default codes for each button: (0001~0104),
DIP4=ON=use the programmed codes, you can program each button on the
door station by ST CONFIG software
DIP5
DIP5: Unlocking time quick selection
DIP5=OFF=unlocking time 0.6 seconds
DIP5=ON=can program by PC through software ( by default 5 seconds)
DIP6
DIP6=OFF=normal mode
DIP6=ON=debug state enter, set to activate the debug state.
Debug mode:
When in this state, use the monitor to call , the outdoor station will call back
automatism