XtendLan DPA-D2-GSM User Manual Download Page 4

3

 

 

 
 

 

The instructions of button:

 

 

Button

 

Descriptions

 

Reset

 

-Press Reset button,it will reset GSM kits

 

Signal Quality

 

-Press Signal Quality button,it will show the signal strength

 

Recover

 

-Press Recover button,it will recover the password defaults

 

Test

 

-Press Test button,it will call the monitor 00

 

 

NOTE:

 

Signal strength show:After press Signal Quality key, 4 LEDs off for a second,

 

then the GSM kits will use 4 LEDs to display signal strength(no signal: 4 LEDs 
off; bad signal: only the LED of Power on; weak signal:only the LED of Power

 

& Network on; good signal: the LED of Power & Network & Status on; strong 
signal:4 LEDs on)for a second, and 4 LEDs off again for a second later, it will 
back to the start state.

 

 

 
 

2.

 

Mounting

 

 

 
 

 

Din rail 

Step1: Mount the din rail to the 
wall with screws ;

 

Step2: Pull down the mounting 
buckle,then hang the unit on 
din rail.

 

 

 
 
 
 
 

Din rail 

 

 

 

Mounting Buckle 

Antenna

 

 

NOTE:A magnet installed on the antenna base, fixed on the 
wall directly adsorbed iron (iron Fortunately, pre-installed on 
the wall) place. In addition, the antenna should be installed 
in the open place, there should be no obstructions around. 

Summary of Contents for DPA-D2-GSM

Page 1: ...DPA D2 GSM GSM unit for D2 videodoor system User s manual...

Page 2: ...on Features Maximum 3 telephone numbers can be set on monitor Must be with Call Transfer function for monitor Divert Calls from monitor to telephone via GSM the GSM is like a telephone when setting th...

Page 3: ...card is detected but unregistered LED flashes rapidly when the SIM card is detected and registered successfully but initialization unsuccessful Always on when the GSM kits work normally Status LED fl...

Page 4: ...Ds off bad signal only the LED of Power on weak signal only the LED of Power Network on good signal the LED of Power Network Status on strong signal 4 LEDs on for a second and 4 LEDs off again for a s...

Page 5: ...Bit5 are invalid Bit 6 must be set to OFF in villa system Total 6 bits for DIP switches to partment application just Bit 6 is useful Bit1 to Bit5 are invalid Bit 6 must be set to ON in partment system...

Page 6: ...rted 2 Divert if not answered outdoor station calls indoor monitor firstly if nobody answer the call within 25 seconds the call will be diverted to the telephone number you set At this mode the monito...

Page 7: ...lling time is more than 5 minutes Calling next telephone number 1 At least 2 telephone numbers must be set on monitor 2 During communication between telephone and outdoor station button has not been i...

Page 8: ...7 7 Specification Power input DC 20 28Vdc supplied by PC6 Power Consumption Standby 60mA working 500mA Working temperature 10 C 40 C Wiring 2 wire non polarity Dimension 90 H X72 W X60 D mm...

Reviews: