 User’s Manual 

 3 

 11

 

 

1. Important safety instructions 

 

 

This symbol indicates 
the presence of 
important directions for 
use and information 
that should be given 
particular attention so 
as to use the product 
properly. 

 

 

 

This symbol indicates 
the presence of 
“dangerous voltage” 
that may cause the risk 
of electrical shock. Pay 
the utmost attention 
and proceed 
cautiously.

 

 

 

 

1. Follow carefully the attached documentation 
and keep it for future reference 
 
2. Comply with the warnings 
 
3. Store the packaging and check that all material 
is in excellent conditions. 

 

4. Do not use water near the product, do not pour 
water or any other liquid on the amplifier. Do not 
to use it with wet hands or feet into the water. 
 
5. Do not use next to heat sources such as 
radiators, stoves or the like. 
 
6. Check the integrity

 of the mains cable. 

Do not 

tread on the cable and do not squeeze the plug.    
 
7. Connect the plug to a socket equipped with 
grounding. Do not camper the plug. If the plug 
supplied is not consistent with your socket, please 
apply to an electrician for its replacement. 
 
8. Connect to supply mains with  the same voltage 
as indicated on the back of the amplifier. 

 

9. Install the amplifier in compliance with the 
instructions.  
 
10. Do not obstruct the air ducts. 
 
11. Disconnect the appliance in case of storm and 
if unused. 

 

12. Connect according to the instructions only.   
 

13. Do not connect input signal higher than that 
indicated in the manual. 
 
14. Do not connect the amplifier output to the 
input of another channel.  
 
15

. Do not connect any output of the amplifier to 

power sources such as battery, voltage supply or 
outlet,

 regardless of the amplifier is on or off. 

 
16. Keep the volume controls to a minimum during 
the amplifier switching on/off . 
 
17. Do 

not remove the upper or lower cover: there 

is a risk of electrical shock. 

 

 
18. Do not try to self-repair the appliance, but 
apply to qualified personnel.  
 
19. Clean with a dry cloth only.  
 
20. The product shall be handled by skilled 
personnel in the following cases: 
 

  mains cable  or plug damaged 

  Exposure of the product to rain or humidity 

  Some liquid entered inside the unit. 

  An object fell on the unit 

  The unit fell down and is damaged  

  The product does not work correctly or shows 

a remarkable change of performance.  

  
21. A careful supervision is necessary if the 
product is used in the presence of children or 
inexpert adults. 
 
22. This product could produce sound levels, 
which cause damage to the hearing. Pay the 
utmost attention and do not operate at high level 
of volume or at an uncomfortable level for a long 
time. Consult an audiometric specialist in case of 
hearing loss or complaints.  
 

 

2. Declaration of conformity

 

 

This device conforms to the requirements of the 
EMC directive  2004/108/EEC, and the 
requirements of the Low Voltage Directive 
2006/95/EEC. 
 
Standards Applied: 
EN55103-1 (Emissions) 
EN55103-2 (Immunity) 
EN60065, Class I (Safety) 

 

Summary of Contents for EV6P

Page 1: ...vo o ol llu u ut t ti iio o on n n S S Se e er r ri iie e es s s P P Pl llu u us s s E E EV V V6 6 6P P P E E EV V V1 1 12 2 20 0 0P P P E E EV V V2 2 24 4 40 0 0P P P A A Am m mp p pl lli iif f fi i...

Page 2: ...atures 5 7 Front Panel Controls and Indicators 6 8 Back Panel Controls and Connectors 6 9 Power Supply 7 10 Connections 7 10 1 General criteria 7 10 2 Balanced Mic Line Input 7 10 3 Pre Out 7 10 4 Mai...

Page 3: ...used 12 Connect according to the instructions only 13 Do not connect input signal higher than that indicated in the manual 14 Do not connect the amplifier output to the input of another channel 15 Do...

Page 4: ...ver s antenna Make sure that the unit concerned conforms to the EMC immunity limits CE labelled All electrical equipment sold in the EC should be approved as for what concerns protection against elect...

Page 5: ...lines and constant voltage This evolved version of Evolution Series has been improved with Noise Gate and Feedback Suppressor processor to optimize the product performance also in very difficult noise...

Page 6: ...OR CONTINUED GND LIFT PRE OUT LINK IN RETURN SEND EFFECT REC AUX 2 AUX 1 CH 6 CH 5 CH 4 CH 3 CH 2 CH 1 BALANCED MICRO LINE INPUT 1Hz 6Hz 15Hz SHIFT PROCESS ON BY PASS 10 0dB FREQUENCY OUTPUT LEVEL ANT...

Page 7: ...necting a microphone it should pay attention to the model if dynamic or electret In case of dynamic microphone do not insert 24 Vdc insert it with electret microphone only CH5 and CH6 socket cannot be...

Page 8: ...loudspeakers that has to be equal or lower than the RMS power value of used amplifier It s a good rule arranging a 10 20 safety margin on the amplifier power capability Constant impedance lines 4 Ohms...

Page 9: ...thermal protection is of the self resetting type and is tripped when the equipment reaches an excessively high temperature This may be due for example to the fact that the ambient temperature is too h...

Page 10: ...microphones are used Ensure that all the Gains and Volume controls are at minimum and that the Tone controls are flat Keep the master volume for each output channel at about 10 20 Keep the input chan...

Page 11: ...1 4V 43 5dBu 5 5mV 1 4V 43 5 dBu 5 5mV 1 4V MICRO LINE Inputs Sensitivity 59 11dBu 0 8mV 218mV 59 11dBu 0 8mV 218mV 59 11dBu 0 8mV 218mV Micro balanced inputs Impedance 10 Kohm 10 Kohm 10 Kohm Bass c...

Reviews: