![background image](http://html1.mh-extra.com/html/xsy/at-series/at-series_manual_3678112016.webp)
P57
Multi function input 1
0: invalid, no output;
1: operating instructions;
2: set arrival instructions
3: fault indication;
4: timer time run out
0
P58
Multi function input 2
Idem
(SP1)
0
P59
Multi function input 3
Idem
0
P60
Multi function input 4
Idem
(relay output)
0
P61
PID options
0: invalid;
1: positive input negative feedback;
2: negative input negative feedback;
3: positive input positive feedback;
4: negative input positive feedback.
0: setting frequency;
1: operating frequency;
14
页
P62
Display options
1: operating frequency;
2: revolution 3: current;
4: temperature; 5: time;
0
P65
Power on options
0: normal power on;
1: report error with start signal when
power on;
2: Power on forward;
3: Power on reverse.
0
P66
Input stabilization time
0---65535
60
mS
P67
Voltage coefficient
0---65535
3250
0
P68
Under voltage setting
0---220.0
160
V
P69
Overvoltage setting
220.0---400.0
300
V