5.0 INSTALLATION OF COLD WATER SUPPLY CONNECTOR
TURN OFF THE COLD WATER SUPPLY BEFORE YOU START
The water supply connector that comes with the unit is made up of three parts; ½” pipe connector, a master shut off valve pressure
reduction valve. See Diagram 1 for connection details. Please contact your local plumber if you are having problems installing the
cold water inlet.
6.0 CONNECTING UP XDC200
Check the labeling detail on XSHG-200 system before connecting up the system.
1.
Connect the
WATER IN
tubing to the master shut off valve, which is attached t
o the ½” pipe connector. With the other
end of the tubing, connect it to the pressure valve followed by the first stage of the XSHG-200 system. The first stage of
the XDC200
system is mark with “
IN
” from the left hand side of the system.
2.
Connect the outlet
“
OUT
” from the XSHG-200 to the sink top faucet.
6.1 QUICK INSERT PUSH IN FITTING
NOTE:
Fittings and tube should be kept clean, bagged and undamaged before use.
Step 1 - Prepare the connection:
Cut the tube square ensuring it is free of score marks. We recommend the use of one of the tube cutter for a perfect cut. For soft or
thin walled plastic tube we recommend the use of a tube insert.
With the fitting clean and undamaged and the tube cut square, you are now ready to make the connection.
Step 2 - Assemble the connection:
Push the tube into the fitting, until the tube stops. The collet (gripper) has stainless steel teeth which holds
the tube firmly in position whilst the 'O' Ring provides a permanent leak proof seal.
Pull on the tube to check it is secure. It is good practice to test the system prior to leaving site and/or before
use. It is recommended (and good practice dictates) that you remember to pressure test the completed
installation before use.
Disconnecting standard push-in fittings:
Ensure system is depressurized before removing fittings. Push in the collet against the tube (center of the
fitting). With the collet held in this position the tube can be removed. The fitting can then be re-used.
7.0 START UP PROCEDURE
1.
With everything connected turn on cold water to unit.
2.
Open faucet on sink.
3.
Turn on the feeding valve.
4.
Check for leaks. (If anything is leaking shut off water, repair, then start with step 1 again).
5.
Within a few seconds the water will start to run.
6.
Let the water run for 10 minutes. This flushes out any carbon fines.
7.
The system is now ready to be used.
8.
Check for leaks daily in the first week and periodically thereafter.
Remember to have your water filter cartridge replaced regularly.