19.0 IMPORTANT NOTICE 

 

Issues which can affect the water quality of RO systems

 

 
Xsential warrants that its reverse osmosis systems will reject up to 92-96% of salts in water.   
The reverse osmosis (RO) technology has been around for many years and has shown that the technology provides 
the best solution when it comes to the protection from scaling of water feed appliances.  Such appliances include 
combi-steamer ovens and coffee machines.   
 
The use of RO systems have also been known to contribute to the extension of life of water feed appliances.  
However, RO systems cannot prevent corrosion from occurring.  RO systems will invariably remove the elements in 
water that could contribute to corrosion thereby prolonging the life of appliances but corrosion can commence in any 
number of ways.   

All corrosion issues should be investigated by a corrosion expert.

 

 
Below are some factors which can affect the warranty and performance of our RO systems.   
 

1.  Water source:  Australia’s water can come from dams, underground wells, desalination plants, or a mixture 

of various sources.  This results in an inconsistent quality of water whereby some water sources could have 
more dissolved salts than others.  For example underground sources of water have more dissolved salts than 
water from a dam.  Hence RO systems might not be suitable for use in some areas.  Highly saline water can 
affect the performance of Xsential’s RO systems.  Please check the water quality with your local water 
authorities. 

2.  Seasonality: 

The concentration of salts in water increases in some seasons due to lack of rainfall while in 

other seasons, the water may be less saline.   

3.  Chemical treatment: 

The amount of chemicals used to treat the water e.g. chlorine, fluoride, etc can lead 

to inconsistencies in the water quality.  Water is treated periodically by the local water authority leading to 
times when the water may contain high doses of elements that can cause corrosion. 

4.  Manufacturer’s water requirements: 

The requirements by individual water feed appliances such as combi 

steamer ovens may vary from the specification produced by Xsential’s RO systems.  The end user should be 
made aware of this. 

5. Wrong 

installation. 

6.  Wrong TDS/water hardness output adjustment.   
7.  Service interval:   it is very important that all of Xsential’s RO systems are serviced regularly.  Failure to 

service (replace filter cartridges) regularly can cause the RO system to not function properly.  See the 
installation manual for details. 

 
Although all care has been taken by Xsential to ensure that its RO systems perform according to its manufacturer’s 
specification, Xsential cannot guarantee the performance of its water treatment systems due to factors which are 
beyond its control.  Some of these factors have been listed above.  End users should be made aware of the factors 
that could affect the life of water feed appliances.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

©

Copyright 2009

 

Unless otherwise stated, this installation manual is Xsential Pty Ltd copyright.  No part of this manual may be reproduced, in whole or in part, 
without the specific written permission of Xsential Pty Ltd. 

Summary of Contents for QuadRO

Page 1: ...D D R RO O Q QU UI IC CK K C CH HA AN NG GE E R RE EV VE ER RS SE E O OS SM MO OS SI IS S S SY YS ST TE EM MS S I IN NS ST TA AL LL LA AT TI IO ON N A AN ND D M MA AI IN NT TE EN NA AN NC CE E M MA AN NU UA AL L ...

Page 2: ...M 8 0 INSTALLATION OF WASTEWATER DRAINAGE 9 0 INSTALLATION OF AX10 TS TRIPLE ACTION SYSTEM 10 0 INSTALLATION OF STORAGE TANK 11 0 CONNECTING UP THE APPLIANCE 12 0 CONNECTING UP FEEDING WATER 13 0 START UP PROCEDURE 14 0 ADJUSTING THE TDS TOTAL DISSOLVED SOLID IN THE WATER 15 0 SYSTEM MAINTENANCE AND FILTER CHANGE PROCEDURE 16 0 XSENTIAL TROUBLE SHOOTING GUIDE 17 0 AUTOMATIC SERVICE REMINDER ASR 18...

Page 3: ...s up to the individual to check for compatibility of Xsential s reverse osmosis system for the intended application Xsential will not be responsible for any wrong installation or water configuration 2 0 QUADRO QUICK CHANGE REVERSE OSMOSIS R O SYSTEM Read through the following instructions carefully before proceeding with the installation Be sure to follow any special plumbing codes in your area Co...

Page 4: ... position 2 Mark screw locations at the desired positions according to the marking and drill the holes 3 Turn the screws into the drill holes 4 Leave screw heads out a little 5 Hang the QuadRO R O system onto screws 6 Cut 4cm of the 3 8 tube and insert into IN of the water inlet location E in diagram 1 7 Insert the 3 8 OD ball valve item D in diagram 1 8 Make sure that the ball valve handle is par...

Page 5: ...4 0 ADJUSTING THE TDS TOTAL DISSOLVED SOLID IN THE WATER Note A TDS tester and water hardness test kit is required for testing the water hardness The TDS tester is used as a guide only The water hardness test kit will be required to test the final hardness of the water The default set up for the system is to reject up to 96 of the impurities in the water Some appliances require a certain level of ...

Page 6: ... very important that the owner checks the water quality regularly to ensure that the reverse osmosis system works properly Parts number Description Recommended service interval depending on the usage water quality QA11 CCF Sediment filter cartridge 3 6 months QA11 GAC Carbon filter cartridge 3 6 months QA11 ROM Reverse osmosis membrane 6 18 months QA11 TX Triple action cartridge 3 6 months Xsentia...

Page 7: ...uality with your local water authorities 2 Seasonality The concentration of salts in water increases in some seasons due to lack of rainfall while in other seasons the water may be less saline 3 Chemical treatment The amount of chemicals used to treat the water e g chlorine fluoride etc can lead to inconsistencies in the water quality Water is treated periodically by the local water authority lead...

Reviews: