Features of the Xs Power
Intelli
CHArGer
The
Intelli
CHARGER is an advanced battery charger designed specifically for high performance lead-acid
batteries. This charger combines the reliability of a transformer and MOSFET rectifier assembly with an
advanced microprocessor control board to create a battery charger that can rapidly and safely recharge
16V gel-cell, and AGM (Absorbed Glass Mat) batteries in several sizes. The front panel switches, LED
indicators, and charge meter make the
Intelli
CHARGER very easy to use.
Multi-Stage Charging
At the heart of the technology in the XS Power
Intelli
CHARGER are the three distinct charging stages. During
the first stage, called “Bulk” charging, the current is fixed according to the charge rate switch on the front
panel and the voltage is allowed to float. During this stage, 80% of the battery’s capacity is restored.
When the battery’s cell voltage comes up to the correct level, the second stage called “Absorption” charging is
engaged. During this stage the voltage is fixed according to the battery type and voltage switches on the front panel
and the current is allowed to float. The battery is brought to 100% during this stage and the cells are equalized.
The third stage is float charging. During this stage the voltage and current are reduced to a level that will
maintain the battery indefinitely.
Several microprocessors are used to tightly control the entire process. This is the same technique that
battery manufacturers recommend and use in the production of new batteries and it is the fastest and
safest technique for battery charging.
Compatible With All 16V AGM and Gel-Cell Batteries
Lead-acid batteries have different charging requirements based on their specific design. Overcharging an AGM
or gel-cell battery will cause permanent damage. If in doubt, contact the manufacturer of the battery being
charged.
Charge Rate Ammeter
The Battery Charger features an ammeter allowing the user to monitor the charging progress.
Voltage Monitoring
The battery’s terminal voltage is measured every five minutes by the on-board microprocessors and
this information is analyzed in addition to the elapsed time to dynamically control the Battery Charger for
optimum charging performance.
Automatic Computer Analysis/Auto Shutdown
The microprocessors will analyze the battery when connected. If the battery’s voltage is below 4V or the battery
will not come up to the correct voltage in a ten-hour period the charger will automatically shut off.
UL Approved Battery Cables
Six feet of durable battery cables are provided that are resistant to cuts and abrasion. The copper plated
battery clamps are compact and custom designed easy connections. All clamp connections are soldered
for maximum current flow.
Internal Cooling Fan
A cooling fan automatically operates during charging to keep the transformer and other internal components
at a constant safe temperature.
XS Power
Intelli
CHARGER
User Guide
Chapter 1
2
1)
Charge Rate Ammeter:
Displays the amount of current flowing into the battery. During stage
one or bulk charging this will be the selected charge rate. During stage two or absorption
charging, this rate will naturally fall to zero as the battery percent of charge approaches 100%.
During float charge, this will read close to zero.
2)
Charging indicator:
Illuminates when the charger is in stage one bulk charging or stage two
absorption charging.
3)
Float Charge indicator:
Illuminates when the charger is in stage three or float charge mode.
4)
Power Switch:
Turns the charger on and off.
5)
Fuse holder:
Contains an 8A fuse in case of overload.
6)
AC cord:
Grounded 3-pin 110V cord for use with grounded outlets only.
7)
Battery clamps and cord:
Allow for connection to the battery.
Front and rear Panel
switches and indicators
Rear Panel
Front Panel
1
4
2
3
5
7
6
CAUTION: It is important to select the correct battery type.
XS Power
Intelli
CHARGER
User Guide
Chapter 1
3