background image

Features of the Xs Power

Intelli

CHArGer

The 

Intelli

CHARGER is an advanced battery charger designed specifically for high performance lead-acid 

batteries. This charger combines the reliability of a transformer and MOSFET rectifier assembly with an 

advanced microprocessor control board to create a battery charger that can rapidly and safely recharge 

16V gel-cell, and AGM (Absorbed Glass Mat) batteries in several sizes. The front panel switches, LED 

indicators, and charge meter make the 

Intelli

CHARGER very easy to use. 

Multi-Stage Charging

At the heart of the technology in the XS Power 

Intelli

CHARGER are the three distinct charging stages. During 

the first stage, called “Bulk” charging, the current is fixed according to the charge rate switch on the front 

panel and the voltage is allowed to float. During this stage, 80% of the battery’s capacity is restored.  
When the battery’s cell voltage comes up to the correct level, the second stage called “Absorption” charging is 

engaged. During this stage the voltage is fixed according to the battery type and voltage switches on the front panel 

and the current is allowed to float. The battery is brought to 100% during this stage and the cells are equalized.

The third stage is float charging. During this stage the voltage and current are reduced to a level that will 

maintain the battery indefinitely.  

Several microprocessors are used to tightly control the entire process. This is the same technique that 

battery manufacturers recommend and use in the production of new batteries and it is the fastest and 

safest technique for battery charging. 

Compatible With All 16V AGM and Gel-Cell Batteries

Lead-acid batteries have different charging requirements based on their specific design. Overcharging an AGM 

or gel-cell battery will cause permanent damage. If in doubt, contact the manufacturer of the battery being 

charged. 

Charge Rate Ammeter

The Battery Charger features an ammeter allowing the user to monitor the charging progress.

Voltage Monitoring

The battery’s terminal voltage is measured every five minutes by the on-board microprocessors and 

this information is analyzed in addition to the elapsed time to dynamically control the Battery Charger for 

optimum charging performance.

Automatic Computer Analysis/Auto Shutdown

The microprocessors will analyze the battery when connected. If the battery’s voltage is below 4V or the battery 

will not come up to the correct voltage in a ten-hour period the charger will automatically shut off.

UL Approved Battery Cables

Six feet of durable battery cables are provided that are resistant to cuts and abrasion. The copper plated 

battery clamps are compact and custom designed easy connections. All clamp connections are soldered 

for maximum current flow.

Internal Cooling Fan

A cooling fan automatically operates during charging to keep the transformer and other internal components 

at a constant safe temperature. 

XS Power

 Intelli

CHARGER 

User Guide

Chapter 1

2

1)  

Charge Rate Ammeter:

  Displays the amount of current flowing into the battery. During stage 

one or bulk charging this will be the selected charge rate. During stage two or absorption 

charging, this rate will naturally fall to zero as the battery percent of charge approaches 100%. 

During float charge, this will read close to zero.

2) 

Charging indicator:

  Illuminates when the charger is in stage one bulk charging or stage two 

absorption charging.

3) 

Float Charge indicator:

  Illuminates when the charger is in stage three or float charge mode. 

4)  

Power Switch:

  Turns the charger on and off.

5)   

Fuse holder:

  Contains an 8A fuse in case of overload.

6)   

AC cord:

  Grounded 3-pin 110V cord for use with grounded outlets only.

7)   

Battery clamps and cord:

  Allow for connection to the battery.

Front and rear Panel 

switches and indicators

Rear Panel

Front Panel

1

4

2

3

5

7

6

 

CAUTION:  It is important to select the correct battery type.

XS Power

 Intelli

CHARGER 

User Guide

Chapter 1

3

Summary of Contents for IntelliCHARGE

Page 1: ...rights reserved Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING XS POWER a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MAN...

Page 2: ...g lead acid batteries These batteries vent explosive hydrogen gas which can be ignited by sparks from electrical connections Never attempt to charge a frozen battery Do not connect DC clamps to the ca...

Page 3: ...ter The Battery Charger features an ammeter allowing the user to monitor the charging progress Voltage Monitoring The battery s terminal voltage is measured every five minutes by the on board micropro...

Page 4: ...6V battery 1 If possible disconnect all loads from the battery by removing battery cables opening a disconnect switch or switching loads off CAUTION Although this is best in a racing environment this...

Page 5: ...rd and input power Charging LED will not illuminate if The battery is not connected The battery is below 4 0V Charge rate does not come up to the selected charge rate initially The battery charger has...

Page 6: ...lower level typically about 2 26 V per cell to maintain the battery s charge without losing electrolyte through gassing In the float mode the charger will initiate a new charge cycle if AC power is d...

Page 7: ...For warranty service the product must be reported to XS Power to receive a unique RGA number return goods authorization and at that time you will be advised of where to send the faulty product All sh...

Page 8: ...will help our representatives give you better service Battery type brand and voltage Is this used with a portable generator Description of the problem Contact Information XS Power 2847 John Deere Dr...