XS Instruments XS BW 3000 User Manual Download Page 6

 

 

 

 

to scroll

 

to scroll

 

to scroll

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                          

          

                                                              

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

How to change value when is 
flashing

 

 

 

Increase the value

 

 

 

Move to next digit

 

Set - Ck 

Set - Hi 

Set - Lo 

Set - Li

 

Set - Bz 

L in - Lo 

L in - In 

L in - Un 

L in - Hi 

3,000  

0,000 

St 

Us 

Bz 

Mu 

Set higher limit 

Set lower limit 

Acustic alarm ON   

Alarm works when measures are 
stable or unstable  

Alarm works only when measure is 
stable 

Acustic alarm OFF 

Confirm the 
selection 

Confirm 

Confirm 

Only when the weight is 
less than the lower limit   

When the weight is 
between lower and 
higher limits   

When the weight is 
less than the lower 
limit or more

 

than 

the higher limit  

 

Only When the 
weight is more 
than the higher 
limit   

!!! 

 

!!! 

 

!!! 

 

!!! 

 

!!! 

 

Set alarm rules 

Confirm the 
selection 

Confirm the selection 

Return to measure 
mode 

Display 

Low 
limit 

High 
limit 

Display 

Display 

Display 

Display 

Summary of Contents for XS BW 3000

Page 1: ...ingress of dust complete protection against contact dust tight 7 Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time up to 1 m of submersion IP 67 User Manual XS BW 3000 ...

Page 2: ... calibration only for no OIML products 4 Calibration procedure 4 Unit Setting 4 Unit selection 4 Zero 4 Tare 4 Measure 5 Function 5 Counter function 5 Limit and Alarm Settings 5 Function settings 7 Battery 8 Troubleshooting 8 Data sheet 8 Disposal of electronic devices 8 ...

Page 3: ... before the first weighing For assistance contact your dealer or an authorized service center Keyboard and definition of keys Press the key for 3 seconds to turn on or turn off the balance Press and weight display to zero when load is in the scope of zero Press the key in weighing mode for 3 seconds to convert unit Press the key and weight displays to zero when load is in the scope of tare weight ...

Page 4: ...n display shows SPAN place 1 kg 2 kg or 3 kg The display shows on1 on2 or on3 in reference with the mass on weighing plate Then display shows pass and count backward to the weighing mode Unit Setting Unit selection When the balance is in weighing mode keep pressed for 3 second to change the unit one by one kg g lb oz pcs The led of the corresponding unit lights on Default unit selected is gram g Z...

Page 5: ...press key Now put all the other samples on the plate to count them Limit and Alarm Settings XS BW3000 allows you to set measures limits higher and lower This function is very useful in a lot of production process to check very fast if the sample respect the specification You can set higher and lower limit alarm rules how alarm has to work and activate or not the sound To activate the check weighin...

Page 6: ...ble or unstable Alarm works only when measure is stable Acustic alarm OFF Confirm the selection Confirm Confirm Only when the weight is less than the lower limit When the weight is between lower and higher limits When the weight is less than the lower limit or more than the higher limit Only When the weight is more than the higher limit Set alarm rules Confirm the selection Confirm the selection R...

Page 7: ...OFF Speed F M i n I n L i n U n A J 0 9 i n U n F Fast M medium S Slow Set the speed of the measurement Set the stability filter from 0 less stability to 9 max stability APF 0 30 20 10 60 Set the auto power off 0 no auto power off 10 auto power off in 10 minutes 20 auto power off in 20 minutes 30 auto power off in 30 minutes 60 auto power off in 40 minutes Display PS 0n off Set the power saving mo...

Page 8: ... error Does not calibrate Recalibrate the scale Look for the right work conditions O load Overload loss weight O zero Exceed initial zero modify settings or remove object Data sheet Capacity 3000 g Division 1 g Repeatability 1 g Linearity 1 g Plate Dimensions mm 220 180 Calibration External RS 232 No rechargeable battery Yes Dual display front and back Yes Disposal of electronic devices The electr...