4
|
XPRESSFILL Systems LLC
265 Prado Road, Suite 1 • San Luis Obispo, CA 93401 • Tel: (805) 541-0100 • [email protected]
the machine, fl ip all switches to their down
or off positions.
Plug the hose from your liquid container
6.
into the port marked “Inlet” on the left side
of the machine using one of the provided
¼” barbed fi ttings. See “Adjusting Pressures”
on page 5.
Plug one end of the provided 4’ x ¼” tube
7.
into the port marked “Vent” on the left side
of the machine, and place the other end
into your catch container.
Plug your air compressor into the port
8.
marked “Air” on the left side of the machine
using one of the provided ¼” barbed
fi ttings. Your fi ller is factory set for 30 psi
keg pressure and 25 psi bottle pressure.
See “Adjusting Pressures” on page 5.
Plug your CO2 tank into the port marked
9.
“CO2” on the left side of the machine using
one of the provided ¼” barbed fi ttings.
Once you are sure that all components
10.
are plugged in correctly, you can open
the valves on your tanks and turn the air
compressor on.
Turn on your machine by fl ipping the
11.
power switch on the right side of your
machine so that it is lit up. Your fi ll
switches should now glow red.
You are now ready to place a bottle on
12.
your machine. Using your right hand, slide
a bottle up onto the stopper and hold in
place.
Step By Step
You will fi rst want to unpack your fi ller
1.
from the shipping box and spread the
components out on a large fl at surface. You
will want to make sure that you also have
the following:
i. CO2 tank with regulator and connecting
tubes (we recommend a wye as well, see
setup diagram for details).
ii. Air compressor and hookup tubings
iii. A small (.5 liter or so) catch container
for collecting vented liquid
Place your fi ller on a fl at surface where you
2.
plan to bottle, ensuring that you have access
to a standard wall outlet or extension cord.
Place the liquid and CO2 tanks, as well as
the air compressor, nearby.
Begin by plugging the provided power cord
3.
into your machine, and then plug it into the
wall. Now is a good time to make sure that
when you turn the machine on, the green
power switch lights up. Th
e fi ll switches on
the front of the machine should glow red.
Toggle the fi ll switches and make sure that
4.
they are red in the down position, and green
in the up position. Waiting a few seconds
after fl ipping the fi ll switch to the up
position should result in the green fi ll lights
also activating.
Once you are sure that you have power to
5.
4
Operating Procedures