XpressFill XF2500 Operating Instructions Manual Download Page 8

4

 | 

XPRESSFILL Systems LLC

265 Prado Road, Suite 1  •  San Luis Obispo, CA 93401  •  Tel: (805) 541-0100  •  [email protected]

the machine, fl ip all switches to their down 

or off  positions.

Plug the hose from your liquid container 

6. 

into the port marked “Inlet” on the left side 

of the machine using one of the provided 

¼” barbed fi ttings. See “Adjusting Pressures” 

on page 5.

Plug one end of the provided 4’ x ¼” tube 

7. 

into the port marked “Vent” on the left side 

of the machine, and place the other end 

into your catch container.

Plug your air compressor into the port 

8. 

marked “Air” on the left side of the machine 

using one of the provided ¼” barbed 

fi ttings. Your fi ller is factory set for 30 psi 

keg pressure and 25 psi bottle pressure.   

See “Adjusting Pressures” on page 5.

Plug your CO2 tank into the port marked 

9. 

“CO2” on the left side of the machine using 

one of the provided ¼” barbed fi ttings. 

Once you are sure that all components 

10. 

are plugged in correctly, you can open 

the valves on your tanks and turn the air 

compressor on.

Turn on your machine by fl ipping the 

11. 

power switch on the right side of your 

machine so that it is lit up. Your fi ll 

switches should now glow red.

You are now ready to place a bottle on 

12. 

your machine. Using your right hand, slide 

a bottle up onto the stopper and hold in 

place.

Step By Step

You will fi rst want to unpack your fi ller 

1. 

from the shipping box and spread the 

components out on a large fl at surface. You 

will want to make sure that you also have 
the following:

i.  CO2 tank with regulator and connecting 
tubes (we recommend a wye as well, see 
setup diagram for details).

ii.  Air compressor and hookup tubings

iii.  A small (.5 liter or so) catch container 
for collecting vented liquid

Place your fi ller on a fl at surface where you 

2. 

plan to bottle, ensuring that you have access 

to a standard wall outlet or extension cord. 

Place the liquid and CO2 tanks, as well as 

the air compressor, nearby.

Begin by plugging the provided power cord 

3. 

into your machine, and then plug it into the 

wall. Now is a good time to make sure that 

when you turn the machine on, the green 

power switch lights up. Th

 e fi ll switches on 

the front of the machine should glow red.

Toggle the fi ll switches and make sure that 

4. 

they are red in the down position, and green 

in the up position. Waiting a few seconds 

after fl ipping the fi ll switch to the up 

position should result in the green fi ll lights 

also activating.

Once you are sure that you have power to 

5. 

Operating Procedures

Summary of Contents for XF2500

Page 1: ...XpressFill XF2500 Counter Pressure Filler Operating Instructions...

Page 2: ...ressfill com Important Safety Instructions Misuse of the bottle lling machine can result in serious injury or death Do not use the machine in any way not covered in this manual or for any purpose othe...

Page 3: ...We guarantee our products to be free of defects in materials and workmanship The ller will be repaired or replaced if upon inspection at the factory the ller is found to be defective in materials or w...

Page 4: ...neumatic ram 10 2 Know Your Filler Bottle ll indicator light 1 Fill sequence start stop switch 2 Quick pressure release button 3 Bottle interior pressure gauge 4 Bottle interior adjustment knob 5 1 2...

Page 5: ...ges should display 5 Bottle Pressure Adjustment Knob This knob allows you to adjust the pressure inside your bottle Turning the knob counterclockwise will lower the pressure while turning it clockwise...

Page 6: ...can be used or a Y tting from your CO2 tank Outlet Container and Tubing 4 Connect the air CO2 and inlet from the keg tubing to their respective attachment points shown in Figure 1 Some air CO2 and li...

Page 7: ...s Your ller is factory set for 30 psi keg pressure and 25 psi bottle pressure The recommended operating pressures for the CO2 and air compressor are listed to the right Please keep in mind that varyin...

Page 8: ...es should now glow red You are now ready to place a bottle on 12 your machine Using your right hand slide a bottle up onto the stopper and hold in place Step By Step You will rst want to unpack your l...

Page 9: ...of the following steps before attempting this Follow steps 1 11 outlined in the setup instructions setting the keg and CO2 pressures to 1 your required values rather than to the recommended settings U...

Page 10: ...r will shut o prematurely stopping the ll or not allowing the ll to begin at all which is characterized by the green LED ll indicator light to ash quickly and stay o as the machine senses a full bottl...

Page 11: ...it inside your ller for a few minutes in order to do its cleaning job Follow the cleaning with a sanitizer For sanitizing we recommend Saniclean from the same manufacturer Saniclean has low foaming ch...