3
TERMINALS
DESCRIPTION
OSDP
CONFIGURATION
WS4
CONFIGURATION
WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
A
RS-485 line
RS-485 A (+)
RS-485 B (+)
X
RS-485 A (+)
B
RS-485 line
RS-485 B (-)
RS-485 B (-)
X
RS-485 B (-)
D0
Output
X
X
D0
X
D1
Output
X
X
D1
X
LG
Input
Input 1
(Dry contact to GND only)
X
Green LED input
Green LED input
LR
Input
Input 1
(Dry contact to GND only)
X
Red LED input
Red LED input
BUZZ
Input
X
X
Buzzer input
Buzzer input
+12V
Power Supply
GND
Ground
T
Tamper
X
(Tamper state is reported
by RS-485)
X
(Tamper state is
reported by RS-485)
T
Tamper
X
X
TERMINALS
DIP SWITCH
CABLING
SIGNALISATION
DIP SWITCH
DESCRIPTION
OSDP
CONFIGURATION
WS4
CONFIGURATION
WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
SW 1
Setup
SCBK Reset: Power the
reader. Set DIP Switch 1
to ON and in the less than
5 sec set it back to OFF
position.
The readers for Doors
1.0 and 2.0 must be at
address 0 and those
for Doors 1.1 and 2.1 at
address 1.
For doors equipped with
2 readers, one must be at
address 0 and the other
at address 1.
X
X
SW 2
RS-485 120 OHM
termination
X
CABLING
DESCRIPTION
OSDP
CONFIGURATION
WS4
CONFIGURATION
WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
Max length
Cable Length
1200m
80m
150m
1200m
Cable
Recommended
cable type
Multiconductor cable
2 twisted pair with
shielding
Multiconductor cable
2 twisted pair with
shielding
Untwisted, shield-
ed, 0.22 mm
2
min.
For longer distance
above 20 m use
larger diameter.
Multiconductor
cable 2 twisted pair
with shielding
SIGNALISATION
DESCRIPTION
OSDP
CONFIGURATION
WS4
CONFIGURATION
WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
Reader ON-LIne
Reader is in
communication
with controller
Managed by Controller
Managed by Controller
Managed by
Controller
Managed by
Controller
Reader OFF-LIne
Reader lost
comunication with
controller
Red LED Blinks
Red LED Blinks fast
X
X