background image

Use mouse click to select the combination you need or use right-click to check or clear entire row or column

Select 

Upload Users to readers 

or 

Delete Users from readers

 at right-click menu

As upload is progressing, check boxes are cleared mining appropriate combination was successfully done
When upload is over, if there are still checked items, repeat the upload command

9.12 CUSTOM WIEGAND

BioManager has defined Wiegand 26 and 34 bit as standard options and other 3 Wiegand settings as user definable.

To setup custom Wiegand format
Select 

Wiegand

 menu from 

Settings

At Wiegand setup window select one from customs Wiegand

Set Wiegand parameter

Click on 

Save

 button

Note:

Wiegand settings are out of scope 
for common end user. Please ask 
your installer to set the parameters 
and do not change it later.

For more information please refer to BioManager User Manual

www.visual-plus.com

20

Summary of Contents for BIOPROX-EM

Page 1: ...BIOPROX EM Biometric Proximity Reader a Company Visual Corporation Plus User s Manual EN v a1...

Page 2: ...E BIOMETRIC READERS 8 6 FIRMWARE UPDATE 8 7 ENTRY MODE 8 7 1 Card or Finger 8 7 2 Card and Finger 8 7 3 Finger Only 8 8 SENSOR CALIBRATION 8 9 SEND CONFIGURATION 8 10 ADVANCED SETTING 9 CONFIGURING TH...

Page 3: ...Consumption Power supply IP Rating Operating Temperature Dimensions mm Biometry and Proximity 125 KHz EM Finger Card Finger or and Card Wiegand 8 to 128 bits Default Wiegand 26bit By PROS software EW...

Page 4: ...w 10 Cor andifthesensorcouldonlybeexposed to direct sunlight it is strongly recommended to install the reader inside a third party sealed wall mount box fitted with additional heater if very low tempe...

Page 5: ...R19 R37 A LD17 A LD19 A LD18 L7 C27 L6 C16 C15 RX4 D5 D10 R32 R33 R35 R49 IC6 ZD5 ZD6 R 2 2 L3 R53 R34 TAS1 IC11 R15 IC15 R3 R4 L8 R47 FUSE1 IC8 R20 R16 R11 C2 X1 C4 IC7 ICN2 R1 C13 C12 ICN1 R23 R48...

Page 6: ...software Thecablemustbetwistedandshieldedwithamin 0 2mm2crosssection Connecttheground 0V ofeachunitinthe RS 485Lineusingathirdwireinthesamecable Theshieldofthecommunicationcablebetweentwodevicesmustbe...

Page 7: ...RS485andwiththe PC SoftwarethroughaConverter The RS485Lineshouldbeconfiguredintheformofadaisychain NOT inaformofastar Keepthestubsfromthe RS485backbone asshortaspossible notmorethan5meters Onlyoneconv...

Page 8: ...ut the serial number of the Biometric Reader 8 3 Important Note The serial number of the reader can be found on a sticker inside the reader on the packaging box and it can be search from the software...

Page 9: ...all Biometric Readers where that user has access i e to all the readers according to the Access Level assign to that user Example If the user has Unlimited Access level then the fingerprints will be...

Page 10: ...where that user has access i e to all thereadersaccordingtotheAccessLevelassigntothatuser Ifthereaderisoffline thefingerswillbesentupontheconnectionisestablishedbetween PROS serverandthereader Noneedf...

Page 11: ...nt readers 8 14 Deleting all users from the biometric reader Right click on the reader and select Delete all users from reader 8 15 Delete one or more fingerprints Select the User and open the Biometr...

Page 12: ...matically and this feature is not used 8 17 Right click on the reader and select Firmware update menu 8 18 On the Firmware update window click on the Browse button 8 19 The default location of the fir...

Page 13: ...the Biometric tab For Entry Mode select Card and Finger 8 21 Use of the double security mode Present the card ex 88009016 in the next 8 sec the reader will blink in orange waiting for the finger Pres...

Page 14: ...eader and select Calibrate and wait for confirmation message Note It is recommended to do a calibration while commissioning the reader and in cases when there are problems with reading the fingers Rig...

Page 15: ...the ones with thermal sensor Fingerprint Transfer Finger templates can be sent to any Reader in the Network Different Users can be sent to different Biometric readers PIN Codes management and transfer...

Page 16: ...online right click on reader and select Upload configuration Check at event table if configuration was successful 9 2 EDIT READER Right click on the reader and select Properties Editreaderpropertiesan...

Page 17: ...de field and enter ID number This number will be sent by the reader to the access controller when user finger is recognized by the reader Click on PIN code field and enter the PIN PIN code is used at...

Page 18: ...percentageofsuccessfulenrollmentgivenrightbesidethefingertip Note If more fingerprints are added for one user all fingerprints will send the same Wiegand Code to the controller 9 9 UPLOAD FINGERPRINTS...

Page 19: ...ckbox Right click on the Reader and select Delete Users The user is deleted from the reader but his fingerprints are stillin the software sdatabase They can be sent ones again without the needofreenro...

Page 20: ...repeattheuploadcommand 9 12 CUSTOM WIEGAND BioManagerhasdefinedWiegand26and34bitasstandardoptionsandother3Wiegandsettingsasuserdefinable TosetupcustomWiegandformat SelectWiegandmenufromSettings At Wi...

Page 21: ...us microseconds Time between two data bits approximately 1 ms millisecond Both data lines D0 and D1 are high Descriptionforthe26bitsWiegandformat EachdatablockconsistsofafirstparitybitP1 afixed8bitshe...

Page 22: ...LED is OFF Check the power Supply red black wire Fingerprint or PIN Code is recognized the tricolor LED is green but the controller reports other ID number and the access is denied If the user is not...

Page 23: ...n las instrucciones del gobierno o autoridades locales para permitir su recuperaci n y reciclado a partir de WEEE Directiva 2002 96 EC w e f 1 de julio de 2006 Gem EU Richtlinie 2002 95 EC 2002 96 EC...

Page 24: ...www visual plus com 24 a Company Visual Corporation Plus Visual Plus Corporation s a Dr ve Richelle 161 WOP G Bte 34 1410 Waterloo Belgium...

Reviews: