Device

Description

Relays

RU2

DIN rail mount remote relay unit

2

DINRTT

Flush mount sensitive push button and remote relay

2

RTT

Surface mount sensitive push button and remote relay

1

RU2

2 Relay Remote Unit

RU1

1 Relay Remote Unit

RTT

1 Relay Remote Unit and 

request-to-exit Button

Secured Area

Outside

B100P-BT-EH-SA

Bluetooth biometric reader

 with integrated proximity reader 

RS-485 (max. 5

0m)

DINRTT

2 Relay Remote Unit and  

request-to-exit Button

4. WIRING AND PAIRING

4.1 Wiring and pairing B100P-BT-EH-SA + RU1

4.2 Wiring B100P-BT-EH-SA to Wiegand Controller

There are four options to wire and pair the reader. It can be paired to RU2, RU1, DINRTT and RTT.

Pairing the reader with remote relay unit is done

from the remote relay unit and enables added

security. After being paired, it is not possible to

switch any of the devices, since the reader will work

only with the paired remote relay unit.

The 

Bluetooth 

reader must be connected to remote

relay unit, unless is used as wiegand reader.

The remote relay units compatible with 

MTPADB-BTEH- SA are RU1, RU2, RTT and DINRTT. 

Once connected, the remote relay unit must be 

paired with the 

Bluetooth

 reader.

Pairing Reader with RU1 (high security)

- Keep the button pressed

for at least 5 sec. and the

units will be paired.

By default, the reader is set to Wiegand 

26 bit.

You can set the reader, using the 

software, to Wiegand 24, 26, 32, 34, 56, 

58 bits.

Other pairing devices: