![XPR Access EX7 Installer Manual Download Page 6](http://html1.mh-extra.com/html/xpr-access/ex7/ex7_installer-manual_3621919006.webp)
Validate by pressing (
B
)
Validation OK?
No
Yes
Start
Enter “Master Code” OR “
000
” (if first time use)
Multiple small beeps
+
Yellow LED blinks rapidly
1 small beep + 1 long beep + Yellow LED is ‘on’
Notes
Memory Position for User Code is always 2 digits
* no need to validate with
A
Assign Examples
Ex.1: To assign User Code “12345” at Memory Position “5” and Relay 1 (2A) in Latch Mode assuming Master Code = 000
Press
000B
+
0
+
05
+
12345
+
A
+
7
+
05
+
1
+
A
+
1
+
00
+
A
+
B
.
Ex. 2: To assign User Code “6789” at Memory Position “6” and Relay 2 that activates for 5 seconds assuming Master Code = 000
See: Assign a User code
See: Assign Output
See: Set Output Timer
PROGRAMMING FLOWCHART
Press
B
(Yellow LED is ‘off’)
No
Yes
End
Press
A
to validate
Validation
OK?
Assign a
User Code
Press (
0
)
+
Memory position
from
01
to
99
Assign Output
Press (
7
)
+
Memory position from
(
01
to
99
)
+
Press (
1
) for Relay 1
And/Or
Press (
2
) for Relay 2
And/Or
Press (
3
) for Relay 3
And/Or
Press (
4
) for Relay 4
Set Output Timer
Pulsed Mode (01 to 99 sec
):
Relay 1 : Press 1
Relay 2 : Press 2
Relay 3 : Press 3
Relay 4 : Press 4
+
01 to 99
Or
Latch Mode (ON/OFF
):
Press (
1
) or (
2
)
or (
3
) or (
4
)
+ (
00
)
Delete
Single Code
Press (
9
)
+
Memory position
from (
01
to
99
)
Enter new code
(
1
to
8
digits)
Delete
All Codes
Press (
8
)
+
(
99
)
Keypad
Reader
Proximity
Reader
Present Card/Tag
before the Reader*
Change
Master code
Press (
0
)
+
Memory
position (
00
)
Assign Relay to
Exit Button
Press (
5
) for PB1
Press (
6
) for PB2
+
Press (
1
) for Relay 1
And/Or
Press (
2
) for Relay 2
And/Or
Press (
3
) for Relay 3
And/Or
Press (
4
) for Relay 4
www.xprgroup.com
DINMTPX-MF v.2
1
6