English - 10
Start Your Job
Turn on the dehumidifier
Press the Power Control button to switch on the machine. You may see the
dehumidification light is flashing. Please wait for 3 minutes (180 seconds) until the
machine completes the startup.
Record Usage Time
• For model XD-85LH/XD-85L2, write down the starting time
right after the
machine starts, if you want to calculate the usage time.
• For model XD-125Li, refer to Quick Start Guide.
Set the desired humidity level
• Tap the humidity control button to adjust the setting humidity level. The default
humidity setting is 30%. The adjust range is from 30% to 90% (
See Page 8: Humidity
Control
). The machine will try to match the setting humidity level and maintain it.
• For model XD-85LH/XD-85L2, if you want the machine to work constantly, please
adjust the humidity level down to 30%, and then press “-” (
See Page 9: Constant
Dehumidification
). Tap “+” to exit constant dehumidification mode.
• For model XD-125Li, refer to Quick Start Guide to enter or exit constant
dehumidification mode.
• If the dehumidifier loses power accidentally, when turned on again, the dehumidifier
will work on the last known configuration.
Dehumidification
• When the machine is dehumidifying, the dehumidification light goes on.
• You may see the dehumidification light is flashing. That means the dehumidification
temporally pauses or the environment humidity has reached the setting level. Please
wait until the machine completes the startup or until the humidity level rises up again.
• The dehumidifier will control the fan speed according to the environment temperature
and humidity.
Defrosting
• When the evaporator coil or the environment temperature is too low, frost may appear
on the evaporator. This will cause a lower effectiveness of the dehumidification. The
machine will start defrosting until the temperature goes back to normal.
• When the machine is defrosting, the dehumidification pauses. The dehumidification
light goes off, and the defrosting light will go on.
• Do not turn off the machine during defrosting process.
CT
F/C
:
°C
%
RH
TOTAL TIME