background image

 1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug 

     the unit with wet hands or while standing in water.

 2. To avoid risk of injury, do not direct air flow at face or any part of body.

 3. To reduce the risk of fire or electric shock, do not use the Air Mover with any solid-state speed 

     control device.

 4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification 

     and / or install GFCI receptacle if necessary.

 5. Do not operate any Air Mover with a damaged cord or plug. Discard the unit or return it to an 

     authorized service facility for examination and/or repair.

 6. Unplug the Air Mover from the power supply before moving, servicing or cleaning.

 7. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, 

     runners, or similar coverings. Place the power cord away from traffic area to prevent tripping.

 8. Do not allow children to play with or around an Air Mover at any time.

 9. Do not move or carry an Air Mover while unit is operating.

10. All Air Movers in operation must be supervised at all times.

Model

P-800/X-800

P-800H/X-800H

X-800C

X-800TF

P-830/X-830

P-830H/X-830H

Volt/Frequency

115V,60H

z

115V,60H

z

115V,60H

z

115V,60H

z

115V,60H

z

115V,60Hz

Power

3/4 H

P

3/4 H

P

3/4 H

P

3/4 H

P

1 H

P

1 HP

Amp

7.5 Amp

s

7.5 Amp

s

7.5 Amp

s

7.5 Amp

s

8.5 Amp

s

8.5 Amps

Unit Weight

23Lbs./24.5Lbs

.

26Lbs./27.5Lbs

.

24.7Lbs

.

24.7Lbs

.

24Lbs./25.5Lbs

.

27Lbs./28.5Lbs.

Speeds

Three

Three

Three

Three

Three

Three

Size(WxDxH)

15.9x17.5x18.5 in

.

15.9x18.7x18.7 in

.

15.9x17.5x18.5 in

.

15.9x17.5x18.5 in

.

15.9x17.5x18.5 in

.

15.9x18.7x18.7 in.

Handle/Wheels

Optiona

l

Incl

.

Optiona

l

Optiona

l

Optiona

l

Incl.

Carpet clamp

Optiona

l

Optiona

l

Incl

.

Optiona

l

Optiona

l

Optional

Timer

N.A

.

N.A

.

N.A

.

Incl

.

N.A

.

N.A.

Filter

Optiona

l

Optiona

l

Optiona

l

Incl

.

Optiona

l

Optional

Cord Length

20 Ft. / 25 Ft

.

20 Ft. / 25 Ft

.

 25 Ft

.

25 Ft

.

20 Ft. / 25 Ft

.

20 Ft. / 25 Ft.

Overheating

Protecting

Thermally

Protected

Thermally

Protected

Thermally

Protected

Thermally

Protected

Thermally

Protected

Thermally

Protected

Rated Airflow

(on high)

3200 CF

M

3200 CF

M

3200 CF

M

3200 CF

M

3600 CF

M

3600 CFM

Positions

4(0°, 20°, 45°, 90°) 3 (0°, 20°,  90°)

4(0°, 20°, 45°, 90°) 4(0°, 20°, 45°, 90°) 4(0°, 20°, 45°, 90°) 3 (0°, 20°,  90°)

Housing

PP / AB

S

PP / AB

S

 AB

S

AB

S

PP / AB

S

PP / ABS

* All models are ETL/CETL certified

Summary of Contents for P-800

Page 1: ...P 800 P 800H P 830 P 830H X 800 X 800C X 800H X 800TF X 830 X 830H 115V 60Hz...

Page 2: ......

Page 3: ...nd stackable up to 3 units high Easy and quick to disassemble for thorough cleaning and service Power cord lengths are 20 for P models and 25 for X models Easy cord wrap on handle Luggage handle and w...

Page 4: ...cal cord into the power outlet 3 Carefully place the Air Mover unit on a stable flat dry surface 4 The unit is capable to be used at 4 different angles to direct air flow except that the unit with han...

Page 5: ...stall GFCI receptacle if necessary 5 Do not operate any Air Mover with a damaged cord or plug Discard the unit or return it to an authorized service facility for examination and or repair 6 Unplug the...

Page 6: ...e the Air Mover in a dry indoor place out of reach of children Air Mover vibrates 2 Never clean the Air Mover with water directly Clean the filters for unit with filters often as necessary to avoid lo...

Page 7: ...5 9x18 7x18 7 in Handle Wheels Optional Incl Optional Optional Optional Incl Carpet clamp Optional Optional Incl Optional Optional Optional Timer N A N A N A Incl N A N A Filter Optional Optional Opti...

Page 8: ...unit that has been dropped subjected to water damage tampered with improper voltage use and unauthorized maintenance and repairs The POWER CORD and filters are not covered by the warranty XPOWER Warr...

Page 9: ...Series Parts List Capacitor 800 1 800 3 800 5 800 7 800 9 800 11 800 13 800 15 800 2 800 6 800 8 800 10 800 12 800 14 15 16 16 Filters 800 16 Timer Switch Plate 4 1 4 2 800 4 1 2 Switch Knob Timer Kn...

Page 10: ...s A set of Filters is available for the Air Mover models which will help prevent small debris and dust from entering the unit To clean the filters Remove the filters from the unit and wash with warm s...

Page 11: ...rranty For a multiple units please list serial numbers on a separate sheet of paper Address XPOWER MANUFACTURE INC 220 Clary Avenue San Gabriel CA 91776 USA Tel 626 285 3301 Fax 626 285 3302 Company N...

Page 12: ......

Page 13: ...per lightweight Easy carrying handle and stackable up to 3 units high Easy and quick to disassemble for thorough cleaning and service Power cord lengths are 20 for P models and 25 for X models Easy co...

Page 14: ...cal cord into the power outlet 3 Carefully place the Air Mover unit on a stable flat dry surface 4 The unit is capable to be used at 4 different angles to direct air flow except that the unit with han...

Page 15: ...ng 10 All Air Movers in operation must be supervised at all times Model P 800 X 800 P 800H X 800H X 800C X 800TF P 830 X 830 P 830H X 830H Volt Frequency 115V 60Hz 115V 60Hz 115V 60Hz 115V 60Hz 115V 6...

Page 16: ...n dropped subjected to water damage tampered with improper voltage use and unauthorized maintenance and repairs The POWER CORD and filters are not covered by the warranty 2 Never clean the Air Mover w...

Page 17: ...eet of paper Address XPOWER MANUFACTURE INC 220 Clary Avenue San Gabriel CA 91776 USA Tel 626 285 3301 Fax 626 285 3302 Company Name Contact Person Title State Province Zip Country 800 1 800 3 800 5 8...

Page 18: ...s A set of Filters is available for the Air Mover models which will help prevent small debris and dust from entering the unit To clean the filters Remove the filters from the unit and wash with warm s...