English - 5
Switch Plate (Continued)
The Quantity of Machines Needed
Ozone Switch
• When the switch reaches “
0
” position, the ozone function stays off.
• When the switch reaches “
I
” position, the ozone function will connect with
power supply. If the fan is functioning, then the ozone function will start; If the
fan is off, or the timer switch reaches “0” position, then the ozone function will
stop.
• On “
ON
” position, it will stay connected with power.
Ozone Indicator Light
• When this light is blinking, it indicates that the ozone function is working.
We suggest this formula to calculate the quantity of the machines needed.
M-25
• Deodorization: 1 unit per 5300 - 10600 ft
3
, or keep ozone concentration within 4
- 8 ppm.
• Air Sterilization: 1 unit per 5300 - 8500 ft
3
, or keep ozone concentration within
5 - 8 ppm.
• Medical Usage / Surface Sterilization: 1 unit per 1060 - 2120 ft
3
, or keep ozone
concentration within 10 - 20 ppm.
M-27
• Deodorization: 1 unit per 10600 - 21200 ft
3
, or keep ozone concentration within 8
- 16 ppm.
• Air Sterilization: 1 unit per 10600 - 17000 ft
3
, or keep ozone concentration within
10 - 16 ppm.
• Medical Usage / Surface Sterilization: 1 unit per 2120 - 4240 ft
3
, or keep ozone
concentration within 20 - 40 ppm.