https://www.XPOtool.com
Item 50622
Page 3
The Tool Experts
08 2022-1
Introduction
Thank you for purchasing this quality product.
To minimise the risk of injury we urge that our clients
take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.
Keep these operation instructions safe.
Safety regulations
•
Always use an earthed power supply with the correct line voltage. The corresponding mains
voltage can be found on the nameplate. If you have any doubts as to whether the connection is
earthed, have it checked by a qualified specialist. Never use a defective power cord.
•
Do not open this device in a damp or wet environment or when you are wet yourself and protect
it from direct sunlight.
•
Install the device in a protected location so that no one can step on, fall over and/or damage
cables.
•
Ensure that there is sufficient cooling by the ambient air and avoid heat build-up.
•
Before cleaning this device, pull the power plug and only use a damp cloth for cleaning. Avoid
using cleaning agents and make sure that no liquid penetrates the device.
•
There are no user serviceable parts inside this device. Leave maintenance, adjustment, and
repair to qualified specialists. In the case of external interference, the 2-year warranty period
expires! Keep these operating instructions in a safe place.
Technical data
Voltage
(V)
220–240
Max. current
(A)
10
Phases
1 (phase and neutral at the same time)
Max. operating pressure
(
㍴
)
6
Pressure setting range
(
㍴
)
1.4–4.1 (continuously adjustable)
Starting pressure setting range
(
㍴
)
1.4–2.8 (continuously adjustable)
Connections
(
㎜
)
13 (¼″) (internal thread)
Operation temperature
(
℃
)
0–55
Colour
Black
Protection class
IP44 (splashproof)
If your pump has an output of more than 1.1
kW, you should connect a commercially available power
protection device or a corresponding power relay. With a 380
V power protection, 380
V/400
V three-
phase pumps can also be controlled.