XPOtool AS19 Instruction Manual Download Page 6

 

https://www.XPOtool.com 

 

Item 34206

 

Page 6 

 

The Tool Experts

 

 

  

 

04 2022-1

 

 

Operating the pressure regulator with filter

 

 
 

a) Pressure regulator

 

b) Pressure gauge

 

c) Water drain plug

 

 
 
 
 
 
 
 
 

 

Product name:

 

 

Pressure regulator with filter and manometer

 

Type: 

   

 

AFR-2000

 

 

Properties

 

AFR-2000 is an in-line low-pressure regulator with 9

 

bar (130

 

psi) manometer and water drain plug. This 

regulator allows you to control the pressure and helps generating clean, dry, and stable air pressure. 
The regulator can only be used according to the operating instructions.

 

 

Operation:

 

1.

 

The pressure gauge reports the working pressure of the air tool.

 

2.

 

Pull up the adjusting knob; a clockwise rotation increases the  pressure, a counter-clockwise 
rotation reduces the pressure.

 

3.

 

Rotate the adjusting knob  to achieve the right working pressure and  engage  it  by pushing it 
downwards.

 

4.

 

Do not rotate the knob against high resistance. If necessary, the height and position of the knob 
can vary slightly.

 

5.

 

For emptying the condensed water collector, use the water drain plug.

 

 
 

Main components

 

 

 

 

Name

 

Double switch

 

a

 

Pressure controller

 

Position 1: Autostop at 4

 

bar

 

Position 2: Maximum pressure at

 

6

 

bar

 

b

 

Pressure gauge

 

c

 

Air connection point

 

d

 

Water release needle

 

e

 

Mains plug

 

 

Summary of Contents for AS19

Page 1: ... may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments ...

Page 2: ...f you have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Ger...

Page 3: ... electrician The voltage of 230 V AC indicated on the nameplate of the device must match the existent mains voltage Never lift transport or suspend the device by its power cord Make sure that the electrical plug connection is protected from flood and moisture Before any maintenance work or adjustment pull out the plug The user is responsible for complying with local safety and mounting regulations...

Page 4: ...tions or if other unusual signs occur that indicate some damage immediately turn off the compressor Do not modify the compressor in any way Only have repairs made by qualified persons and using original spare parts Properties Air tank emits regular pulsation free air flow Oil free piston compressor no polluted air With water filter pression adjustment and manometer Double air pressure switch Switc...

Page 5: ...ssure has built up and the auto stop function has been activated If there is no leakage the pressure gauge should display nearly constantly the same range of pressure A quick decrease of the range of pressure suggests that there is in fact a leakage It is of great importance to seal any leak as soon as possible to avoid any impact on the capacity and efficiency of the compressor A leakage leads to...

Page 6: ...ating instructions Operation 1 The pressure gauge reports the working pressure of the air tool 2 Pull up the adjusting knob a clockwise rotation increases the pressure a counter clockwise rotation reduces the pressure 3 Rotate the adjusting knob to achieve the right working pressure and engage it by pushing it downwards 4 Do not rotate the knob against high resistance If necessary the height and p...

Page 7: ... the user Reinstall cylinder valve and place it in the right direction Engine runs but makes noises Bearings are loose or damaged Replace bearings Screws in connecting rod loose Tighten or replace screws Airbrush gun does not function properly insufficient blowing pressure Air connection not tight Seal air connection with insulat ing tape Air hose torn off Re mount the air hose Screws of cylinder ...

Page 8: ... Screw 4 20 Screw 2 35 Wire 6 Stationary motor 21 Front gasket 36 Rubber pad 4 7 Bearing 2 22 Front cover 37 Hexagon head nut 8 Rotary motor 23 Filter 38 Connection 2 9 Front main unit 24 O ring 39 Connection piece 2 10 Counterweight 2 25 Cylinder block 2 40 Screw 11 Pressure gauge 26 O ring 2 41 Pressure controller 12 Bearing 2 27 Cylinder head 2 42 Plug 13 Retainer ring 2 28 Cap screw 8 43 Three...

Page 9: ...on and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the protection of the environment a...