Inspections, maintenance, and cleaning
Warning!
Before carrying out any inspection, maintenance or cleaning work, make sure that the
throttle control
(20)
is in the off position and that the compressed air tool is disconnected from its air
supply.
1.
Before each use, inspect the general condition of the tool and check for loose screws, mis-
alignment or jamming of moving parts, cracked or broken parts, and other circumstances that
could affect safe operation. If you hear strange noises or vibrations, have the problem correc-
ted before further use. Do not use damaged devices.
Fig. 2
№ Name
1
Oil plug
(13)
2
Adjusting screw
(2)
2.
If necessary, fill the hydraulic system with high quality hydraulic oil. Remove the oil plug
(13),
top up with oil, then reinsert the oil plug
(13)
(see Fig. 2).
3.
To adjust the punch, loosen the adjusting screw
(2)
and turn the tool head. Re-tighten the ad-
justing screw
(2)
after you have made the desired setting.
Maintenance chart
Intervention
Before use
After use
Check tool for damages.
X
Check oil level.
X
Wipe with clean, damp cloth
.
X
Troubleshooting
Problem
Possible causes
Possible solutions
Device does not start
Air supply not connected
Ensure that the air supply is
properly connected to the tool.
Air hose not connected securely
or damaged, resulting in air leak-
age
Check all air hoses and connec-
tions. If the air hose is damaged,
replace the damaged hose. Do
not repair damaged areas with
tape or the like.
The device does not work evenly
when punching and/or flanging.
Possible dirt/deposits in moving
parts
Make sure that the anvil
(9)
and
clamp
(1)
as well as the punch
die
(3)
and punch
(6)
are free of
dirt and deposits.
https://www.XPOtool.com
Item 62797
Page 6
The Tool Experts
04 2021