https://www.XPOtool.com
Item 61963, 61964, 61965
Page 4
The Tool Experts
05 2022-1
Resistance
•
The maximum temperature of the pumped liquid should not 35
℃
in continuous oper-
ation.
•
Never transfer flammable, gassing, or explosive liquids with this pump.
•
Never use the pump for other liquids, especially engine fuels, cleaning agents, and other chem-
ical products!
Electrical connection
•
The electrical connection is made to a 230
V ~ 50
Hz protective contact socket. Fuse protection
at least 10
A.
•
The indicator lamp inside the switch lights up when the engine is switched on.
•
The motor is protected against overloading or blocking by the thermal motor protection built-in.
In case of overheating, the overheating protection of the motor switches the pump off automat-
ically. After cooling down, the pump automatically switches on again.
Installation
The pump is installed as follows: either in a fixed position with fixed piping or in a fixed position with
flexible piping.
Please note!
•
When installing, make sure that the pump does not hang loose on the pressure line or the power
cable. The submersible motor pump must be hung up on the supplied handle or rest on the floor
of the shaft.
•
To ensure that the pump functions properly, the bottom of the shaft must always be free of
sludge or other dirt.
•
If the water level is too low, the sludge in the sump can dry up quickly and prevent the pump
from starting. It is therefore necessary to check the submersible motor pump regularly by per-
forming a start-up test.
•
The float switch is set so that it can be put into immediate operation.
Note:
The pump shaft should have at least the dimensions of 40×40×50
cm so that the float switch can
move freely.
Mains connection
This waste water pump is already provided with a safety plug. The pump is intended for connection to a
safety socket with 230
V ~ 50
Hz. Make sure that the socket is adequately fused (at least 6
A) and
functional. Insert the pump plug into the socket, the pump is ready for operation.
Important:
If the power cord or plug is damaged due to external influences, never repair them yourself!
The cable must be replaced with a new one, a job that should only be carried out by a qualified electri-
cian.
Functionality
The pumps are equipped with an open or closed impeller mounted at the end of the drive shaft. They
are surrounded by a large, circular chamber and a base plate with a mechanical interior. The suction
opening inside the base plate is in direct contact with the liquid to be pumped. The rotating impeller
transfers kinetic energy centrifugally into the circular chamber, where part of the kinetic energy is