11
XPLORE TECHNOLOGIES
iX104C5 RUGGED TESTING AND CERTIFICATION SUMMARY
10
MIL-STD-810G TESTING
ALTITUDE
Chamber at 50,000 ft for 1 hour. Unit is operating. MIL-STD-810G, Method 500.5, Procedure II
CONTAMINATION BY
FLUIDS
Detergents, brake fluid, aromatic hydrocarbons. Unit is not operating. MIL-STD-810G, Method
504.1
FUNGUS
28 days; US Fungus Types. No growth. Unit is not operating. MIL-STD-810G, Method 508.6,
Procedure I
SOLAR RADIATION
Steady State A1. 1120 W/m2 (355 Btu/ft2/hr) UVB @ 50°C, 7x24hr cycles. Unit is not
operating. MIL-STD-810G, Method 505.5-2, Procedure II
INGRESS TESTING
IEC (IP) INGRESS
PROTECTION TESTING
IP 67 (10-cell battery) Dust tight, no ingress of dust. Protection against effects of immersion
in water to 3.28' (1m). IEC 60529 IP-67 for dust and water. IP65 with 8-cell battery option.
HAZARDOUS ENVIRONMENTS TESTING AND CERTIFICATION
UL1604/ISA STD 12.12
(CSA 22.1)
Operation in Hazardous Environments; (Class 1, Division 2, Zones A/B/C/D)
ATEX AND IECEx
Operation in Hazardous Environments; ATEX and IECEx compliant
ADDITIONAL COMPLIANCE
AUTOMOTIVE
Compliance with latest version of EU Directive 72/245/EEC including amendments and
corrigenda (2004/104/EC) Automotive E Mark (xDock)
iX104C5 ELECTROMAGNETIC COMPATIBILITY SUMMARY
10
CHARACTERISTIC
SPECIFICATION REqUIREMENT LIMITS/LEVELS
TEST METHOD
Electrostatic Discharge
EN55024
+/-8 kV (Direct), +/-15kV (Air)
EN 61000-4-2
Radiated Immunity
EN55024
3 V/m 80-1000 MHz
EN61000-4-3
Electrical Fast Transients
EN55024
+/- 1 kV AC and DC Power Lines,
+/- 500 V Signal Lines
EN61000-4-4
Surge Immunity
EN55024
2 kV AC Line-Gnd, 1 kV AC Line-Line and
I/O Signal Lines if applicable
EN61000-4-5
Conducted Immunity
EN55024
3V/m 150 kHz to 80 Mhz
EN61000-4-6
Magnetic Immunity
EN55024
Power Frequency Magnetic Field
Immunity 1A/m
EN61000-4-8
Electromagnetic
Compatibility
EN55024
Voltage Dips, Short Interruptions and
Voltage Variations Immunity
EN61000-4-11
Electromagnetic
Compatibility
EN55024
Limits for Harmonic Current Emissions
EN61000-3-2
Electromagnetic
Compatibility
EN55022
Limitations of Voltage Changes, Voltage
Fluctuations and Flicker
EN61000-3-3
Radiated Emissions
EN55022
47CFR Pt 15
Electric Field Emissions, 30 MHz to
18 GHz
EN55022, Class B
FCC Pt 15, Class B
Conducted Emissions
EN55022
47CFR Pt 15
Power Leads, 150 kHz to 30 MHz
EN55022
FCC Pt 15, Class B
RUGGED DESIGN
TESTING/
CERTIFICATIONS
DATA PROTECTION
PROVEN RUGGED IN THE REAL WORLD