CONFIDENTIAL
PRODUCT MARKETING BULLETIN IX104TU082304_v1
Page 3 of
4
3. Features:
3.1
Two Bays for Battery Charging:
The Charger provides two charging bays that will charge
sequentially
. Charging is limited to
3000mA per bay. The first battery inserted will get charged first.
3.2
One Bay of Battery Reconditioning:
3.2.1 Only the left bay of the Charger provides battery reconditioning by a push-button (the center Blue
Arrow button) activation.
3.2.2 The recondition algorithm is a full full dis final full charge.
Note:
Recondition does not affect the battery chemistry, but resynchronizes the SMBus fuel gauge
chip with the state of charge of the physical cells.
4. Status
Indicators:
One Tri-Color LED will provide status indication for each charging or charge/ recondition bay. The color
codes are as follows:
LED Color: Description:
Off
No battery detected
Flashing Green
Charging
Solid Green
Fully charged
Flashing Yellow
Recalibrating
Yellow/Green Recalibrated
Solid Yellow
Standby (waiting for other bay to complete)
Flashing Red
Error
5. Charging
Instructions:
5.1 Charging:
5.1.1 Simply insert one (1) iX104 battery pack into one of the slots. If desired, you may place
another battery pack into the other slot (
see note #1
).
5.1.2 The first battery inserted will start to charge immediately, but it takes about 10-15 seconds
for the fan to turn-on, and the charging sequence to begin.
5.1.3 The second battery will remain waiting until the first battery has completed its charge cycle.
Note #1:
The slots are keyed, so you can only place the batteries into them in the correct
orientations.
5.2
Reconditioning:
(
see note #2
)
Insert one (1) battery pack into the left bay, then press and hold the Reconditioning Button until the
Flashing Yellow LED is on.
Note #2:
Xplore Technologies, Inc. recommends reconditioning the battery pack once every
three (3) months, or when the run time is significantly reduced.