Window Kit Component Parts 

 

 

Minimum 30 seconds 

Maximum 30 minutes 

 

Installation 

 

In a window glazing unit with a Ø115mm prepared hole at least 110mm in from the edges of 
the glazing beads to the centre of the hole.  With a maximum thickness of 43mm. 

 

As far away as possible from and opposite to the main source of air replacement to ensure 
airflow across the room (e.g. opposite the internal doorway). 

 

Near the source of steam or odours. 

 

 

 

Not where ambient temperatures are likely to exceed 50°C. 

 

If  installed  in  a  kitchen,  fans  must  not  be  mounted  immediately  above  a  cooker  hob,                                  
or eye level grill. 

 

If installing in a room containing a fuel burning device which has a non-balanced flue, it is 
the installer's responsibility to ensure that there is enough replacement air to prevent fumes 
being  drawn  down  the  flue  when  the  fan  is  operating  up  to  maximum  extract.                                          
Refer to Building Regulations for specific requirements. 

 

Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances 
supplied with energy other than electric. Requirements of all authorities concerned must be 
observed for exhaust air discharge and intake flow rates. 

 

Not suitable for use in possible chemical corrosive atmospheres. 

 

 

What the installer will need. 

 

No.1 or 2 Pozidrive screwdriver. 

 

Method 

 

Remove  backing  from  gasket,  insert  window  duct  through  hole  and  adhere  window  duct  to 
window. 

ENSURE

 slots in window duct face downwards as shown in diagrams. 

 

Insert locator ring into window duct. 

 

Insert the 4 pegs into the appropriate holes in the locator ring to ensure the minimum clearance 
between peg and the outside surface of the window. 

 

Gently tighten the 4 x M3 6mm long pan-head clamp screws to clamp the window kit in position.  
(

CAUTION

 over tightening may shatter the window). 

 

Install fan in window kit in accordance with its installation instructions using the 3 x M4 8mm 
long screws provided. 

Summary of Contents for Simply Silent SSWIN

Page 1: ...tallation instructions Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning UK customers If you have any queries before or after installing this product call the Xpelair Technical Hotline 44 0 844 372 7766 Our engineers are there to help you during normal office hours Or you can fax at all other times on 44 0 844 37...

Page 2: ...idity RH value External operation When switched off using the external on off switch the fan continues to run for the preset delay from 30 seconds to 30 minutes Factory settings Timer 15 minutes RH 75 Kit must be installed with slots orientated downwards as shown Overall Dimensions mm This window kit should only be installed by a competent person into a suitable glazing unit with a pre prepared ho...

Page 3: ...ulations for specific requirements Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates Not suitable for use in possible chemical corrosive atmospheres What the installer will need No 1 or 2 Pozidrive screwdriver ...

Page 4: ...ring Xpelair Newcombe House Newcombe Way Orton Southgate Peterborough PE2 6SE UK Telephone 44 0 844 372 7761 Sales Spares Hotline 44 0 844 372 7750 Fax 44 0 844 372 7762 Sales Spares Faxline 44 0 844 372 7760 http www xpelair co uk International Guarantee Contact your local distributor or Xpelair direct for details Technical Advice and Service Contact your local Xpelair distributor Cleaning recomm...

Page 5: ...or Fans Bathroom Lighting Shower Seats Grab Rails Shower Curtains Toilet Brushes Bathroom Cleaning Products Wall Mounted Bathroom Accessories Robe Hooks Bathroom Tumblers Toilet Roll Holders Soap Dishes Towel Rings Shower Caddies Bathroom Mirrors Standard Bathroom Mirrors LED Bathroom Mirrors Shaving Mirrors ...

Reviews: