Preparing the Fan for installation.

1. Remove the front cover/baffle assembly by

depressing the latch on the underside of 

the cover and pulling off the front cover / 

baffle from the bottom (See Figure C).

If working above ground floor  
level, safety precautions must 
be observed. 

Mark the position of the back-plate

2. Hold the back-plate so that the level line

marked on it is orientated horizontally.

3.  Carefully insert the fan tube into the wall duct.

4. Mark on the wall the positions of the fixing

holes in the back-plate.

5. Remove the back plate from the ducting.

6. Drill screw holes in these positions if

necessary, and fit wall plugs and screws

as required. The fan may also be fixed to a

wall tube using the clamping brackets. See

9 below.

If installing in a ceiling, appropriate 
termination ancillaries are 
required. Follow instructions 
provided.

Mount the back-plate.

7. Feed the mains cable through the

cable entry hole in the back plate to the 

terminals. If surface mount wiring ‘break 

out’ the side wall in the duct flange for 

cable entry (See Figure F)

8. Insert the fan tube of the back-plate into

the wall duct/ceiling as before.

9. Fasten the back-plate to the wall/ceiling

using appropriate fasteners. See figure A.

10. If using screws, do not over tighten. The

fan may also be fixed to a wall tube using

the clamping brackets. Tighten the screws

until the fan is firmly secured to the tube –

see figure B.

Wire the electrical connections.

11. Make sure the mains supply is isolated.

Switch off the mains electrical supply and 

remove fuses.

12. Feed the cable to the terminal block. Wire

the fan as shown in Figure G using the 

diagram appropriate to the fan model.

13. Connect the cable from the isolating switch

to the electrical supply wiring.

Fan Settings

SPEED SETTING

The fans are factory set to low speed, but have 

two speed settings for different applications. 

Select either high or low speed by connecting 

the jumper between the centre and high or low 

speed pin on the jumper (see Figure F) 
C4TS / C4TR Only.

• To adjust the over-run period turn the control

(T) clockwise to increase and anti-clockwise 

to decrease – see Figure D.

English

For fixed wiring circuits the protective fuse 
for the appliance must not exceed 5A.

C6S/C6R

C6PS/C6PR

C4TS/C4TR

C4HTS/C4HTR

G

FAN

TERMINALS

FAN

TERMINALS

DOUBLE POLE

ISOLATING SWITCH

DOUBLE POLE

ISOLATING SWITCH

ON/OFF 

SWITCH

LAMP

(IF REQUIRED)

FUSE

FUSE

English

Summary of Contents for Simply Silent C4S

Page 1: ...C4S 92960AW C4R 92961AW C4TS 92962AW C4TR 92963AW C4PS 92964AW C4PR 92965AW C4HTS 92966AW C4HTR 92967AW Xpelair Simply Silent Contour English Installation and Maintenance Instructions...

Page 2: ...supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for the benefit of the user Standard C4S 92960A...

Page 3: ...at installation Built in back draught shutter C4S C4R Operate the fan using an on off switch not supplied C4PS C4PR Operate the fan using an integral pull cord C4TS C4TR Built in timer operates fan f...

Page 4: ...TE Fan switches on at lower level of condensation anti clockwise MORE SENTITIVE RH 50 Fan runs on for a shorter time when the external switch is turned off Fan does not switch on until higher level of...

Page 5: ...CUSTOMER CONNECTION TERMINAL SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING CUSTOMER CONNECTION TERMINAL CUSTOMER CONNECTION TERMINAL LOW SPEED HI...

Page 6: ...poles must be incorporated in the fixed wiring in accordance with wiring regulations If metal switch boxes are used earthing regulations must be followed The cross sectional area of the supply cord u...

Page 7: ...to the wall duct ceiling as before 9 Fasten the back plate to the wall ceiling using appropriate fasteners See figure A 10 If using screws do not over tighten The fan may also be fixed to a wall tube...

Page 8: ...sembly by hooking in the top first and then swing the cover down to clip into place If surface mount wiring break out the thin wall section in the front cover prior to re fitting see figure E The mini...

Page 9: ...By telephone on Techline 44 0 844 372 7766 By fax on Techfax 44 0 844 372 7767 At the address below Head Office UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe Way Orton S...

Page 10: ...Office UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe Way Orton Southgate Peterborough PE2 6SE England Telephone 44 0 844 372 7761 www xpelair co uk www xpelair co uk int...

Reviews: