7. Mount the fan in the hole (Fig. 4).

Xpelair recommend that the instructions of this section are carried 
out by two people.

If  working  above  ground  floor  level,  appropriate  safety 
precautions must be observed.

If  installing  the  fan  in  a  window,  fix  the  three  rubber  edge 
protectors (packed separately), at equal distances around the lip of 
the Outer Clamp Plate.

1. Attach the ladder strips (packed separately) to the Outer Clamp 

Plate.

2. Hold the Outer Grille up to the outside of the  wall or window 

so that the lip of the Outer Clamp Plate protrudes into the hole.

3. Hold the Inner Clamp Plate to the inside of the wall or window 

and guide the ladder strips from the Outer Clamp plate through 
the slots in the Inner Clamp Plate.

4. Insert  the  slotted  screws  (packed  separately)  into  the  pockets 

around the ladder strip slots

5. Tighten the screws carefully to make a good seal.

Do not over-tighten the screws.

6. Trim the ladder strips back to the required length. If necessary 

remove any sharp edges.

8. Refit the Fan to the Inner Clamp Plate.

1. Fit the Fan assembly onto the Inner Clamp Plate (Fig. 3).
2. Make sure  that  the ladder strips go  inside  the  fan  assembly so 

they will not get caught in the blades.

3. Tighten up the four screws. 

Do not over-tighten

.

9. Wire the electrical connections

1. Remove  the  fan  Connector  Plate  carefully  by  unscrewing  the 

two  screws  (Fig.  5). The black  Connector  Assembly  parts  are 
contained loosely behind this plate.

2. Remove  the  two  cable  clamp  screws  in  the  black  connector 

assembly (Fig. 8).

3. If  required,  feed  the  cable  through  the  grommet  (packed 

separately)  in  order  to  fit  to  the  cable  entry  of  the  Connector 
Plate.

4. Wire the Fan Connectors as shown in Fig. 6.

10. Fitting the cable clamp:

For mains cable up to 6mm diameter, clamp the cable as shown in 
Fig.8a
For  mains  cable  equal  to  or  greater  than  6mm  and  up  to  10mm 
diameter, clamp the cable as shown in Fig. 8b.
For mains cable greater than 10mm diameter, use the conduit entry 
provided (Europe only).

11. Fitting the Connector to the fan:

1. Ensure the mains cable is firmly retained by the clamp.
2. Assemble the  black  fan  connector by  snapping the cover  over 

the connector (Fig. 7).

3. Plug the black fan connector into the fan assembly.
4. Refit the Connector Plate.
5. Refit the Back-draught Shutter.
6. Refit the Inner Grille.
7.

Switch off the mains electrical supply and remove fuses.

8. Connect the cable from isolation switch to the electrical supply 

wiring.

9. Replace the fuses, and switch on the mains electrical supply. 

For  fixed  wiring  circuits  the  protective  fuse  for  the  appliance 
must not exceed 5A.

12. Pairing the RF switch to the fan

To  prevent  interference  between  other  RF  systems,  the  fan  and 
switch need to be ‘paired’ together.

1. Remove  the  inner  grille  by  first  removing  the  screw  from  the 

underside of the grille then unclipping the bottom of the grille, 
the top of the grille can then be released by unclipping the top 
corner.  NOTE: The top of the grille can only be released when 
the  screw  is  removed  and  the  bottom  of  the  grille  has  been 
released (Fig. 2)

2. Press the ‘pairing’ switch on the fan ‘on’ (Fig. 10)
3. Refit the inner grille.
4. Take  the  RF switch  and  operate adjacent  to  the  fan.  Once  the 

fan  operates,  switch  and  fan  are  ‘paired’.

There  is  a  2  minute 

period  after  pressing  the  pairing  switch  when  fan  and  RF 
switch can be paired. After this time the fan defaults to the non-
pairing condition.

5. Re-fit screw to underside of grille.

13. Operating the fan

•  This  fan  provides  a choice  of  5  running  speeds  or  passive 
ventilation  when  operated  by  the  appropriate  RF switch. Refer  to 
the instructions for the controller for operating instructions.
• The shutters have a time delay of up to 1 minute on opening, and 
up to 3 minutes on  closing.  Activated by  operation of  the  switch, 
the delay ensures quiet operation. 

WARNING  – This  appliance  can  be  used  by  children  aged 
from  8  years  and  above  and  persons  with  reduced  physical, 
sensory capabilities or lack of experience and knowledge if they 
have been given  supervision  or  instruction  concerning the use 
of  the  appliance  in  a  safe  way  and  understand  the  hazards 
involved. Children shall not play with the appliance.
Cleaning and maintenance  of the appliance  shall  not be made 
by children.

14. Trickle ventilation

Trickle ventilation is equivalent to that provided by an air brick or 
similar device.
1. Remove the Inner grille and back draught shutter (see ‘Mounting 
the fan in the hole’ section). 

To allow trickle ventilation:

2. Release the Shutter Return Spring as shown in Fig. 9
3. Re-Position the Shutter Return Spring into the L-shaped slot.
4. Raise the Operating Bar to latch into position.

To fully close the shutters and stop any back draught

5. Unlatch the Shutter Return Spring and re-position into short slot.
6. Refit the Back-draught Shutter and Inner Grille.

15. Maintenance

NOTE: A QUALIFIED ELECTRICIAN MUST CARRY OUT 
ALL CLEANING.
1

Before  cleaning,  isolate  the  fan  completely  from  the  mains 

supply.  Allow  3  minutes  for  the  impeller  to  stop and  the 
powered shutter to close.

2. Remove the inner grille and back-draught shutter (see section 6)
WARNING:  Fan  will  still  operate  when  the  inner  grille  is 
removed. 
3. Remove the impeller by unscrewing the knob at the front of the 
impeller anticlockwise.
4. Clean  the  back  draught  shutter,  inner  grille  and  impeller  by 
immersing in warm soapy water. Dry thoroughly.

Do not immerse the fan in water or other liquids to clean any 
other parts of the fan.

5. Refit the impeller by locating it over the motor shaft. Make sure 
the impeller is seated correctly.
6. Refit the knob making sure the ratchet at the rear of the knob is 
fully engaged.

Summary of Contents for GX12 EC3 RF

Page 1: ...GX12 EC3 RF fan Installation and maintenance instructions Retain for future reference ...

Page 2: ...equirements Exhaust air must not be discharged into a flue used for exhausting fumes from appliances supplied with energy other than electric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates When intended for use in possible chemical corrosive atmospheres consult our Technical Service Department For overseas market contact your local Xpelai...

Page 3: ...gether 1 Remove the inner grille by first removing the screw from the underside of the grille then unclipping the bottom of the grille the top of the grille can then be released by unclipping the top corner NOTE The top of the grille can only be released when the screw is removed and the bottom of the grille has been released Fig 2 2 Press the pairing switch on the fan on Fig 10 3 Refit the inner ...

Page 4: ... Refit the screw covers Never use strong solvents to clean the fan Apart from cleaning no other maintenance is required NOTE THE FAN WILL CONTINUE TO OPERATE WITH THE INNER GRILLE ASSEMBLY REMOVED HENCE IT MUST BE ISOLATED COMPLETELY FROM THE MAINS BEFORE ANY WORK IS CARRIED OUT Fig 1 Fig 3 Step 3 Step 3 Step 2 Step 1 Fig 2 ...

Page 5: ...Fig 4 Fig 8a Fig 8b Operating bar Shutter return spring Fig 9 Fig 5 Fig 7 Fig 6 ...

Page 6: ...Components Fig 10 A Inner Grille B Back draught shutter assembly C Fan assembly D Inner Clamp Plate E Outer Clamp Plate Grille F Ladder Strips G Connector Plate H Pairing Switch Fig 10 ...

Page 7: ...This page has been left blank for the addition of any notes you may wish to make ...

Page 8: ...h In the event of a product being returned to Redring Xpelair Group Limited and not found to be faulty the product would be available for collection from the relevant premises within one month and if not collected it would be disposed of or delivered by Redring Xpelair Group Limited and a delivery charge made EXCLUSIONS This guarantee DOES NOT cover damage or defects arising from poor or incorrect...

Reviews: