How It Works

This product is a dehumidifier. It controls relative humidity by passing the air through 
the unit, forcing the excess moisture to condensate over the cooling elements. 
Contact with this cold surface causes the moisture in the air to condense. This condensed 
water then drains safely into the water tank. The dried air then passes through the condenser 
where it is slightly warmed and re-enters the room at a slightly elevated temperature. 
N.B. As with all compressor type dehumidifiers their effectiveness is reduced the colder 
the ambient temperature is. Do not use where the ambient temperature is 5°C or lower.

Water tank

               

Fan

              Compressor

Motor

Evaporator

Condenser

Air Outlet

Air Inlet

1.  Before switching on for first time please ensure unit has settled for 12 hours.

2. Please remove ‘carbon filter’ from its bag and locate between the anti- dust filter       
     and air inlet on the body of the product (make sure carbon filter is lined up properly 
    with guide locators on the air inlet).

3. Ensure pre filter and carbon filter is fitted securely to the product before switching on.

4. Plug product in.

5. Press on/off button.

6. Select the humidity control button and keep pressing until ‘cont’ lights up- this will   
    set product to run continuously-  leave to 3 minutes then adjust humidity control to 
    your desired setting.
    The lower the setting e.g 40% the product will try and target 40% relative humidity    
    (ambient humidity) which is for drier conditions.  Nearer 70% setting, the product 
    will try and target 70% relative humidity e.g. more humid/ moist conditions.  Unless 
    this setting is changed, the product will now start controlling the ambient 
    humidity in the room.

Quick start/ First time operation

7

Summary of Contents for everdri 10 E

Page 1: ...CTION MANUAL Models 10 14 E and EL These products fully comply with all current European Safety Standard requirements for Dehumidifiers and are fully compliant with the Low Voltage Directive 2014 35 E...

Page 2: ...lectric heaters stoves or other sources of ignition When defrosting and cleaning the appliance do not use any tools other than those recommended by the manufacturing company The appliance must be plac...

Page 3: ...damage Never operate the appliance if a cable or connector has been damaged after appliance malfunction or if the appliance was dropped or is otherwise damaged If the mains lead is damaged it must on...

Page 4: ...flammable or explosive substances or fuels Never use any paint cleaning sprays anti insect sprays or similar near the unit this could damage or deform the plastic cause electrical damage or be a fire...

Page 5: ...xtension lead may become overload Where there is risk of fire or close to a naked flame Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals If there...

Page 6: ...scharge Pressure MPa 2 2MPa 2 2MPa Maximum Pressure of Coil MPa 9 6MPa 9 6MPa Refrigerant R290 GWP 3 Refrigerant Charge kg 0 035kg 0 065kg CO2 Equivalent tonnes 0 000105 tonnes 0 000195 tonnes Contain...

Page 7: ...ensure unit has settled for 12 hours 2 Please remove carbon filter from its bag and locate between the anti dust filter and air inlet on the body of the product make sure carbon filter is lined up pr...

Page 8: ...rflow This dehumidifier is fitted with castors for extra mobility if you move the unit it should first be switched off and the water tank emptied We do not recommend the use of an extension lead so pl...

Page 9: ...indicator as to the optimum comfort level of humidity It is designed to be a guide only if you wish to keep the unit running when the light is red to tackle severe damp conditions then do so Blue ligh...

Page 10: ...t the same time the unit will work 3 hours continuously choose 1 2 and 4 hours at the same it will work 7 hours Thus the timer could be set up to 15 hours In this case all the hour indicator lights ar...

Page 11: ...midity levels the water tank will require more frequent emptying In this situation it may be more convenient to set the unit up for continuous drainage this can be done as follows 1 Pull out the water...

Page 12: ...arge the active carbon properties WASHING THE PLASTIC DUST FILTER Remove the anti dust filter and separate the active carbon filter not washable and set it aside carefully Use a vacuum cleaner or tap...

Page 13: ...is not damaged ERROR FAULT CODE MESSAGES ON DISPLAY 1H or 2H Flashing Sensor malfunction Please stop using the product Contact Customer Service 4H Flashing Connection malfunction Please stop using th...

Page 14: ...cilities exist Check with your Local Authority or retailer for recycling advice in your country If you don t intend to keep the packaging of this product for later use or storage please dispose of it...

Page 15: ...ation and proof of purchase we will contact you to make the necessary arrangements If your Dimplex product is not covered by this Dimplex guarantee there may be a charge to repair your product However...

Page 16: ...ee will not extend the guarantee period The Dimplex guarantee does not entitle you to recovery of any indirect or consequential loss or damage including but not limited to loss or damage to any other...