For Australia Only –C6TS / C6TR / C6HTS / C6HTR
These models are permanently connected to the supply and opera
ti
on is controlled by a remote switch. They should be directly
wired to the supply through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts.
1. Remove the front cover/ba
ffl
e assembly by depressing the latch on the underside of the cover and pulling o
ff
the front
cover / ba
ffl
e from the bo
�
om (See Figure C).
Mark the posi
tio
n of the back-plate
2. Hold the back-plate so that the level line marked on it is orientated horizontally.
3. Carefully insert the fan tube into the wall duct.
4. Mark on the wall the pos
i�
ons of the
fixing
holes in the back-plate.
5. Remove the back plate from the du
c�
ng.
6. Drill screw holes in these posi
�
ons if necessary, and
fit
wall plugs and screws as required. The fan may also be
fix
ed
to a wall tube using the clamping brackets. See 9 below.
Mount the back-plate.
7. Feed the mains cable through the cable entry hole in the back plate to the terminals.
8. Insert the fan tube of the back-plate into the wall duct/ceiling as before.
9. Fasten the back-plate to the wall/ceiling using appropriate fasteners. See
figu
re A.
10. If using screws, do not over
�g
hten. The fan may also be
fix
ed to a wall tube using the clamping brackets. Tighten the
screws un
�l
the fan is
fi
rmly secured to the tube – see
fi
gure B.
11. Make sure the mains supply is isolated. Switch o
ff
the mains electrical supply and remove fuses.
12. Feed the cable to the terminal block. Wire the fan as shown in Figure F using the diagram appropriate to the fan
model.
13. Connect the cable from the isola
�
ng switch to the electrical supply wiring.
Summary of Contents for C6S
Page 4: ...Wiring and se ng up...