15
C O N T R O L S
If you are working WITH A PARTNER without an XP wireless headphones:
you can use FREQ. SHIFT.
✓
on the middle setting: DETECT Freq1 / WS1 OFF position on
YOUR device.
✓
on a high setting: DETECT Freq 2 / WS1 CH1 position on your
partner's device, even if they are not using an XP wireless
headset.
If you are working WITH A PARTNER, with an XP wireless headphones:
you can use FREQ. SHIFT
✓
on a low setting: DETECT Freq 1 / WS1 CH2 position for YOUR
device
✓
on a high setting: DETECT Freq 2 / WS1 CH1 position for your
partner's device.
In any event, please refer to the XP wireless headphones user
manual before use.
IRONLEVEL______________________________
____
This control allows you to adjust the audio level
of the low tone (iron signals, also coke).
•
Min.
= iron (low) tone is off
•
Max.
= you will now hear all low tones
•
Intermediate levels
will allow you
adjust to whatever level you prefer.