XONOX CT 200 Operating Manual Download Page 9

 

Operating Manual CT 200 

 

Installation 

 

X O N O X

  T e c h n o l o g y   G m b H / / 3 5 6 2 5   H u e t t e n b e r g / / G e r m a n y  

P h o n e   + 4 6   6 4 4 1   9 6 3 6 4 0 / / F a x   + 4 9   6 4 4 1   9 6 3 6 4 1 0 / / w w w . x o n o x - t e c . c o m

 

Page 9 of 14 

 
 

3.2.

 

Alignment 

 

 

Illustration 7: Centering by using the alignment bushing 

 

 
 
 
 

1.

 

loose the 4 screws of the adapter for the manual 

chuck. 
 
 

2.

 

Insert the alignment bushing 

 
 

3.

 

Putting down the upper probe 

 

4.

 

Adjust the manual chuck until upper probe fits 

easily through the alignment bushing.. 

 
5.

 

tighten the screws of  the adapter fort he manual 

chuck 

 

 

 

 
 
 
 
 
 
 
 
 

 

 
 
 

Summary of Contents for CT 200

Page 1: ... N O X T e c h n o l o g y G m b H 3 5 6 2 5 H u e t t e n b e r g G e r m a n y P h o n e 4 6 6 4 4 1 9 6 3 6 4 0 F a x 4 9 6 4 4 1 9 6 3 6 4 1 0 w w w x o n o x t e c c o m Operating Manual XONOX CT 200 ...

Page 2: ...X O N O X T e c h n o l o g y G m b H 3 5 6 2 5 H u e t t e n b e r g G e r m a n y P h o n e 4 6 6 4 4 1 9 6 3 6 4 0 F a x 4 9 6 4 4 1 9 6 3 6 4 1 0 w w w x o n o x t e c c o m ...

Page 3: ...ly 4 2 Product description 5 2 1 Configuration 5 2 2 Operation elements 6 3 Installation 7 3 1 Adjustment 7 3 1 1 Adjustment of the Lenses 7 3 1 2 Adjustment of the upper and lower measuring key button 8 3 2 Alignment 9 4 Safety Instructions 10 4 1 General safety instructions 10 5 Function and measurement 11 5 1 Function of the measuring gauge 11 5 2 Calibration 11 5 3 Measuring procedure 12 5 4 U...

Page 4: ... instructions Dear Customer always keep the instruction manual near to the XONOX CT 200 Only qualified people are allowed to use the XONOX CT 200 1 2 Scope of supply The scope of supply consists of XONOX CT 200 3x lens support tips short 3x lens support tips long Respective holder Gauge block 10mm Probe tips 1x steel plan 2x PEEK 5mm 2x PEEK 3mm Alignment bushing Combination pliers Allen key 3mm M...

Page 5: ...6 4 1 0 w w w x o n o x t e c c o m Page 5 of 14 2 Product description 2 1 Configuration Illustration 1 XONOX CT 200 exposition with inscription 1 Mitutoyo digital gauge 543 564D 2 Input valve pneumatic 3 Respective holder gauge block 10mm 4 Lower probe 5 Manual chuck 6 Switch lower probe UP DOWN 7 Switch upper probe UP DOWN 8 Holding adapter for lenses 9 Upper probe 1 5 9 8 7 6 2 4 3 ...

Page 6: ...4 4 1 9 6 3 6 4 1 0 w w w x o n o x t e c c o m 2 2 Operation elements Mituoyo digital gauge 543 564D Turn on and off Display for indication of measurements Adjustment Preset See chapter 5 1 or operating manual measuring gauge 543 564D Remote control for Mitutoyo digital gauge 543 564D Manual chuck centering the lens Switch for the upper probe UP DOWN Switch for the lower probe UP DOWN ...

Page 7: ... the Lenses Illustration 2 Centering device without lens 1 Holding adapter for lenses 2 Manual chuck 3 Adapter for manual chuck Illustration 3 Change position of holding adapter for lenses 1 Front position oft he holding Adapter for lenses 2 Change position depending on lens diameter 3 Thread for holding adapter for lenses Illustration 4 Holding oft he lens 1 Open the manual chuck 2 attaching the ...

Page 8: ... a x 4 9 6 4 4 1 9 6 3 6 4 1 0 w w w x o n o x t e c c o m 3 1 2 Adjustment oft he upper and lower measuring key button Illustration 5 Adjusting the upper probe 1 Release the clamping 2 Adjust the measuring key 3 Lock the clamping Illustration 6 Adjust the lower probe 1 Hold the lower probe 2 Release the probe 3 Adjust the lower probe 4 Lock the clamping 1 3 2 2 4 1 3 ...

Page 9: ... 1 0 w w w x o n o x t e c c o m Page 9 of 14 3 2 Alignment Illustration 7 Centering by using the alignment bushing 1 loose the 4 screws of the adapter for the manual chuck 2 Insert the alignment bushing 3 Putting down the upper probe 4 Adjust the manual chuck until upper probe fits easily through the alignment bushing 5 tighten the screws of the adapter fort he manual chuck 2 3 1 ...

Page 10: ...6 6 4 4 1 9 6 3 6 4 0 F a x 4 9 6 4 4 1 9 6 3 6 4 1 0 w w w x o n o x t e c c o m 4 Safety Instructions 4 1 General safety instructions Only qualified people are allowed to use the XONOX CT 200 While measuring do not put any extremity in operation range see picture at the bottom Consider the risks of injury cuts and crushing Illustration 8 area of danger ...

Page 11: ...t Press and hold the SET ZERO key for long time Preset system Leading sign is accentuated Press Mode to change the leading sign Press the SET ZERO key quickly Preset system Moves to next digit Adjust the preset of 10mm Press the SET ZERO key quickly Preset system Run over the Preset menu until nothing is accentuated anymore Press SET on the radio control Preset value is supposed automatically 5 2 ...

Page 12: ... he measuring key button 1 Upper probe DOWN 1 2 Lower probe UP 2 3 Measuring value is shown on measuring gauge 4 Lower probe DOWN 3 5 Upper probe UP 4 Illustration 12 Control of the measuring key button Labels regarding the respective switches for the control of the measuring key button 5 4 Using the probe tips In order to avoid damages to the polished surfaces by using contaminated plastic balls ...

Page 13: ...ge 13 of 14 6 Appendix 6 1 Technical Data Working range 60mm travel of measuring gauge on different adjustable positions Diameter range 10 200mm Measuring system Digital gauge with 0 5μ resolution Accuracy Digital gauge 2 0μ Repeat accuracy 1μ Total accuracy depending on lens geometry Dimension WxDxH 300x460x650mm Weight Approx 30kg Connections Power 100 240V 50 60Hz Compressed air 6 bar Color Lig...

Page 14: ...00 Appendix Page 14 of 14 X O N O X T e c h n o l o g y G m b H 3 5 6 2 5 H u e t t e n b e r g G e r m a n y P h o n e 4 6 6 4 4 1 9 6 3 6 4 0 F a x 4 9 6 4 4 1 9 6 3 6 4 1 0 w w w x o n o x t e c c o m 6 2 Pneumatic plan ...