20
XOMAX
XM-RSU255BT
EN
Topic:
Common solutions
Describtion of the
problem
Cause and solution
The unit does not
turn on.
This problem is in most cases caused due to a wrong connec-
tion of the ISO cable.
Please review the pin assignments of the ISO plug and ISO
socket. Pay attention to the proper connection of the ignition-
and steady plus and correct the discrepancy if required.
Note:
Though the design of ISO port is standardized, it's pin
assigment is not and may vary. Thus in case of mismatch
of connections due to different pin assignments a simple
plug'n'play connection may lead to grievous errors.
Radio stations are
lost:
As soon as the unit
will be turned off all
the stored stations
and user's settings will
be lost.
This problem is caused due to a wrong connection of the ISO
cable.
Please interchange the cables for ignition plus and for steady
plus.
Caution:
If these wires have fuses, the latter should be interchanged as
well.