DAMAGED BATTERY

 

Any sign of physical damage or abnormal behavior of the battery system (or its peripheral components) 

 

should be treated with extreme caution.

 

ACTION

 

•  Disconnect the power.

 

•  Keep away from the battery and contact XOLTA.

 

•  Never use the damaged battery system again.

 

1.4  XOLTA approved, authorized installers

 

XOLTA provides appropriate training to installation technicians for XOLTA systems.

 

The XOLTA Compact BESS must only be installed and commissioned by a XOLTA approved installer. 

 

1.5  Safe disposal of Lithium-ion batteries

 

Li-ion batteries must be treated as hazardous waste and not be disposed of with regular household waste.

 

For safe disposal of an unusable XOLTA battery it can be delivered back to the manufacturer or importer  

 

that originally sold the battery or to the dealer of a new industrial battery.

 

1.6  Disclaimer

 

We have taken every precaution to ensure that all information provided in this manual is correct and up  

 

to date. However, to the extent permitted under the applicable laws, we assume no responsibility for damage  

 

to persons and property arising as a result of following recommendations and/or procedures described in  

 

this manual. Furthermore, we assume no responsibility for any infringements of rights of third parties which  

 

may result from the use of this manual.

 

Product modifications or changes to the product environment:

 

 

•  Only use the storage system in its original state - without any unauthorized modifications - and when it is 

 

 

  in proper working order.

 

•  Safety devices must never be overridden, blocked or tampered with.

 

•  The interfaces of the storage system must be wired in accordance with the product documentation.

 

•  An appropriate and readily accessible disconnect device shall be incorporated in the fixed wiring.

 

•  All repairs on the storage system must be performed by authorized service technicians only.

 

•  The replacement of battery modules must be undertaken by authorized service technicians only. When  

 

  replacing batteries, replacement must be with the same type and number of batteries or battery modules.

 

 

1.7  Legal

 

The system has been designed to ensure that an installed BAT-5 or BAT-10 and all its associated functionalities  

 

behave safely under the predefined operating conditions. However, please read all sections about safety and

 

 

precautions carefully before installation, operation, or undertaking service work on a XOLTA BESS. Failure  

 

to do so could result in reduced system performance, damage to the system, personal injury or even death.

Summary of Contents for BAT-5

Page 1: ...Advanced energy storage systems for solar system installations BATTERY SYSTEM MANUAL XOLTA COMPACT BAT 5 AND BAT 10 2021 by XOLTA...

Page 2: ...and BAT 10 8 2 2 XOLTA Compact BESS benefits 8 2 3 Maximizing consumption of solar power 8 2 4 Modularity and scalability of XOLTA BAT 5 and XOLTA BAT 10 9 2 5 Key specifications 10 3 XOLTA Battery En...

Page 3: ...ons or repairs undertaken by unqualified personnel or due to failure to follow the following important safety instructions The safety instructions have been divided into WARNING indicates a dangerous...

Page 4: ...inhaling the odor The XOLTA Compact BESS is heavy Suitable lifting equipment is strongly recommended Do not paint any part of the product Do not open the battery modules For long term storage longer...

Page 5: ...at and fire Hazardous fumes such as carbon dioxide carbon monoxide and hydrocarbons are emitted during battery fires ACTION Disconnect the power from the battery system at the electrical panel if poss...

Page 6: ...cedures described in this manual Furthermore we assume no responsibility for any infringements of rights of third parties which may result from the use of this manual Product modifications or changes...

Page 7: ...constantly out of service due to Purchaser for a period of more than six months after the initial installation The Covered Product has not been serviced properly and professionally or according to tec...

Page 8: ...d commercial use The batteries are an essential enabler for the transition to renewable energy by balancing out volatile energy production with consumption The high energy density means little space i...

Page 9: ...s can be connected on the AC side both on the same grid phase or the different grid phases The resulting battery power and energy capability are presented in Table 2 1 XOLTA BAT 5 and in Table 2 2 XOL...

Page 10: ...ds UN38 3 classification for safe transportation EN 61010 1 2010 A1 2016 IEC 62619 2017 EN 61000 6 2 Industrial level EN 61000 6 4 Class A Region dependent and subject to service agreement TECHNICAL P...

Page 11: ...can be connected and operated in parallel giving up to 10 8kW and 30kWh MULTIPURPOSE The battery is designed for various applications solar self consumption time shifting etc XOLTA CLOUD CONNECTION Th...

Page 12: ...by a best in class battery management system BMS and battery protection unit BPU The BMS is responsible for monitoring protection and diagnostics of battery cells Battery cells and power conditioning...

Page 13: ...re of all the fast response requests from the grid It can ensure that the system operates safely without the internet connection and collects moderate amount of data as back up As shown in Figure 3 3...

Page 14: ...to IP55 Enclosure Protection Rating for dust and water jets Install outdoor in a shaded location or on a north north east facing wall The battery should not be immersed in water or exposed to high te...

Page 15: ...oved electrician Any subsequent changes or modifications by unauthorized personnel are strictly prohibited and could compromise safety X 3 6kVA 5kWh 3 6kVA 10kWh L1 L2 L3 N PE Internet Cloud 1P N PE 2...

Page 16: ...st 70 of initial battery capacity will be maintained The capacity is determined in amp hours Ah at a temperature of 25 C and a discharge rate of 0 2C rate from fully charged 100 SoC The warranty appli...

Page 17: ...monitor your battery you need to go to the XOLTA Web App and register your battery there Go to app xolta com For the best experience we recommend using the Google Chrome browser A step by step guide c...

Reviews: