background image

- 6 -

Installa

tion P

repar

ation

Duct 

Piece:

Dimensions:

Equivalent 

Number 

Length*:

Quantity

Used:

Total

Equivalent

Length:

Round, straight 1 ft. (per foot 

lenhgth)

3-1/4" x 10" 

straight

1 ft. (per foot 

lenhgth)

90° elbow

12 ft.

45° elbow

7 ft.

3-1/4" x 10"

3-1/4" x 12"

90° elbow

14 ft.

10 ft.

3-1/4" x 10"

3-1/4" x 12"

45° elbow

8 ft.

6 ft.

3-1/4" x 10"

3-1/4" x 12"

90° elbow

33 ft.

24 ft.

6" round to 

rectangular

2 ft.

Rectangular to 

8" round

2 ft.

3-1/4" x 10"

3-1/4" x 12"

6" round to 

rectangular 

transition 90° 

elbow

4 ft.

4 ft.

3-1/4" x 10"

3-1/4" x 12"

Rectangular to 

6" transition 

90° elbow

4 ft.

4 ft.

Round wall 

cap with 

dramper

24 ft.

3-1/4" x 10"

3-1/4" x 12"

Rectangular 

wall cap with 

dramper

24 ft.

18 ft.

Round roof 

cap

33 ft.

*Actual  length  of  straight  duct  plus  duct 

fitting equivalent. Equivalent length of duct 

pieces are based on actual tests conducted 

by  GE  Evaluation  Engineering  and  reflect 

requirements for good venting performance 

with any ventilation hood.

Total Duct Run =

DUCT FITTINGS:

This Hood Must Use an 

6" Round Duct. It Can 

Transition to 3-1/4" x 10" 

or 3-1/4" x 12" Duct.

Use  this  chart  to  compu-

te  maximum  permissible 

lengths  for  duct  runs  to 

outdoors.

NOTE: Do not exceed ma-

ximum permissible equiva-

lent lengths!

Maximum  duct  length: 

100  feet  for  range  ho-

ods.

Flexible ducting:

If flexible metal ducting is 

used, all the equivalent feet 

values in the table should be 

doubled. The flexible metal 

duct should be straight and 

smooth  and  extended  as 

much as possible.

DO NOT use flexible plastic 

ducting.

NOTE: 

Any home ventilation 

system, such as a ventilation 

hood,  may  interrupt  the 

proper flow of combustion 

air  and  exhaust  required 

by fireplaces, gas furnaces, 

gas water heaters and other 

naturally vented systems. To 

minimize the chance of in-

terruption of such naturally 

vented systems, follow the 

heating equipment manu-

facturer’s  guidelines  and 

safety  standards  such  as 

those published by NFPA.

Summary of Contents for XOT30S

Page 1: ...ation CAMPANA EXTRACTORA Manual de utilización USA F E XOT30S XOT36S NEED HELP Call our ventilation experts toll free al 800 966 8300 NEED HELP Call our ventilation experts toll free al 800 966 8300 NEED HELP Call our ventilation experts toll free al 800 966 8300 ...

Page 2: ...iginal purchaser for products purchased for ordinary home use in North America Should you require service for your XO product call a product service specialist at 800 966 8300 Improper Installation Service trips to the home to teach you how to use the product Resetting circuit breakers Damage caused after delivery EXPECT MORE FROM XO When buying any XO appliance you can be confident you have purch...

Page 3: ...s and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for further information and requirements WARNING TO REDUCETHE RISK OF FIRE ELECTRIC SHOCK OR INJURYTO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you h...

Page 4: ...inguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit aBased on kitchen firesafety tips published by NFPA Proper maintenance of the Range Hood will assure proper performance of the unit INSTALLATION I...

Page 5: ...s after a prolonged use of the appliance C No food must be cooked flambè underneath the hood D The use of an unprotected flame is dangerous for the filters and could cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F Before performing any mainteinance operation disconnect the hood from the elec trical service The manufacturers will not to accept any respons...

Page 6: ...ation Engineering and reflect requirements for good venting performance with any ventilation hood Total Duct Run DUCT FITTINGS This Hood Must Use an 6 Round Duct It Can Transition to 3 1 4 x 10 or 3 1 4 x 12 Duct Use this chart to compu te maximum permissible lengths for duct runs to outdoors NOTE Do not exceed ma ximumpermissibleequiva lent lengths Maximum duct length 100 feet for range ho ods Fl...

Page 7: ...pe or Duct Tape INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the hood and the outside 2 A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof or wall cap Connect 6 round metal...

Page 8: ... 8 Hood Specifications Product dimensions and clearance XOT30S XOT36S Front of hood Side of hood Top of hood Mounting height and clearance ...

Page 9: ...e air outlet Fig 1B or Fig 1C the wires set up in the relevant fairleads must be released by pulling the lever outwards as indicated in figure 2 phase 1 2 B Disconnect the 6 way quick coupling of the motor located inside of the hood as show in figure 2 phase 3 C The wires positioned inside of the hood are fasted with a cable tie Cut the cable tie as shown in figure 2 phase 4 Once transformation op...

Page 10: ...sion prepare the air evacuation hole It is recommended to use an air evacuation pipe with the same diameter as the air outlet flange The use of a reduction could decrease product performance and increase noise I M P O R TA N T T h e r a n g e h o o d m u s t b e s e c u r e d t o w a l l studs or use drywall anchors capable of supporting 75 lbs ...

Page 11: ... available in 2 different positions which can be used according to your requirements 1 in the upper part of the hood Fig 3A 2 in the rear part of the hood Fig 3B The air evacuation flange is supplied with the rectangular shape X and circular shape Y Fig 3 Fig 3 ...

Page 12: ...electric connection box positioned in the rear part of the hood as indicated in figure 4B see paragraph connection to the electric power supply If a rectangular air outlet pipe is used E the hood is already set up Fig 4A 1 If however a circular air outlet pipe is to be used F the 7 screws H must be removed along with the bracket X Fig 4A 2 Fig 4 ...

Page 13: ...arry outallphasesshowninfigure5B removethescrewsI Fig 5A 1 thatfixthemotorbracket Y and turn the entire motor unit and position it as indicated in Fig 5A 2 Put the motor bracket Y back in its seat and fix it with the previously removed screws I Attention Whenever a circular air outlet pipe is to be used F the operation indicated in Fig 5C 2 must always be repeated ...

Page 14: ...t be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Route house wiring as close to the installation location as possible in the ceiling or back wall Refer to Wiring Locations on page 15 Connect the hood wiring to the house wiring in accordance with local codes Grounding instructions The grounding conductor must be conn...

Page 15: ...of the hood to those of the power supply as described Fig 6 3 BLACK L line WHITE N neutral GREEN YELLOW G ground A double pole switch properly rated must be installed to provide the range hood power supply disconnection Connect the electrical conduit to the Field Wiring Compartment using listed onduit fittings Carry out the power supplly connection in accordance with the national electric code ANS...

Page 16: ... box must be positioned in the seat To move the electric power supply box refer to that indicated in Fig 7A 1 Loosen the two screws C Fig 7A 1 2 Break and remove the small circular metal sheet positioned in the upper part of the hood with the aid of a flat screwdriver Fig 7A 2 3 Take the electric connection box and fix it using the 2 screws C previously removed in the position indicated in Fig 7A ...

Page 17: ...combined cooker stoves If a connection ductwork composed of two parts is used the upper part must be placed outside the lower part Do not connect the range hood exhaust duct air to the same duct air used to exhaust hot air or fumes from other appliances other than electrical 3 Connect the Ductwork ...

Reviews: