- 15 -
2. CONNECT ELECTRICAL:
t
Power Supply Connection
For connection to the power supply refer to the follows
Fig.3-Fig.8
:
BLACK = L
line
WHITE = N
neutral
GREEN/YELLOW = G
ground.
- A double-pole switch properly rated must be installed to provide the range hood
power supply disconnection.
- Connect the electrical conduit to the Field Wiring Compartment using listed conduit
fittings.
- Carry out the power supplly connection in accordance with the national electric code,
ANSI/NFPA 70-1999.
5. Insert the wires into the box, then close the box cover, securing it using the screws
that were previously removed.
The appliance must be installed at a minimum height of 27" from an electric cooker stove,
or 32" from gas or combined cooker stoves. If a connection ductwork composed of two
Fig.8