background image

- 20 -

easy to operate

BUTTON   :

  Controls the LED lights. There are three illumination levels.

Press the button Once for HIGH; Twice for MEDIUM; Three times for LOW; Four times for OFF.

BUTTON 0:

  Turns both the Blower and Lights On and Off

BUTTON 1:

  Blower motor operates on 

LOW

 speed.

BUTTON 2:

  Blower motor operates on 

MEDIUM

 speed.

BUTTON 3:

  Blower motor operates on 

HIGH

 speed.

POWER BOOST

Press and Hold BUTTON 3 for 2 seconds.

This will increase airflow to a fourth and even higher speed for 10 minutes.  

When activated the button will blink to alert you it is running.

After 10 minutes the blower speed will return to its last setting.

To manually stop the 

POWER BOOST

 before 10 minutes has elapsed: 

Press 

BUTTON 3

 and it will revert to HIGH speed, or

Press 

BUTTON 0

 to shut the blower off completely

NOTE:  The POWER BOOST function will operate even when the hood is off.

BUTTON T:

  Activates and Deactivates the 

TIMER

 Function

Pressing 

BUTTON T

 (whether the blower is off or running) will cause the motor to run at 

LOW

 

speed for 5 minutes before shutting off the blower and lights automatically.

While the 

TIMER

 is activated, you can change speed or engage 

POWER BOOST,

 the hood 

will still shut off after 5 minutes.

To manually turn the unit off before 5 minutes has elapsed:

Press 

BUTTON T

 or 

BUTTON 0

.  

Your  XO  range  hood  is  controlled  by  these 

electronic push buttons which illuminate when 

activated.

 

REMOTE

 

CONTROL

 

(included)

 

The remote control must be synchronized prior to use.

To synchronize the remote control with the hood follow these simple 

steps:
1. Standing near the hood, while it is not running, press and hold 

BUTTON   on the hood for 4 seconds -the button should start to 

blink for 5 seconds.
2. When the button on the hood starts to blink, Press any button on 

the remote. The hood and remote are now synchronized.
3. If the synchronization fails for any reason, repeat steps 1 and 2.

XOVREMOTE1

Summary of Contents for XOCEILING36S

Page 1: ...I worked really hard on this manual so please read it XO CEILING MOUNT MODELS XOCEILING36S XOCEILING42S...

Page 2: ......

Page 3: ...ance com priority service for your xo product Or by phone 973 403 8900 CONGRATULATIONS on purchasing your XO Before you proceed take just a moment to register your XO at www xoappliance com register y...

Page 4: ...READY Safety and Precautions Planning Ductwork Install Examples Dimensions THE INSTALL Mounting Height Installing Electrical Connections MAINTENANCE Filters Cleaning Recirculation Light Replacement O...

Page 5: ...esidential Kitchen ventilating use only Do not use to exhaust haz ardous or explosive materials and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spra...

Page 6: ...USE WATER including wet dishcloths or towels a violent steam explosion will result D Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2...

Page 7: ...A Do not check filters with hood working B Do not touch the lamps after a prolonged use of the appliance C No food must be cooked flamb underneath the hood D The use of an unprotected flame is danger...

Page 8: ...ee chart WHEN YOU MUST USE FITTINGS TRY TO SEPARATE THEM WITH SECTIONS OF 3 OR MORE OF STRAIGHT DUCT ALWAYS FOLLOW THE MANUFACTURER S GUIDELINES FOR THE COOKING EQUIPMENT YOU ARE VENTING IF MAKE UP AI...

Page 9: ...TER THE NUMBER OF EACH TYPE OF TURN YOU ARE USING AND THE TYPE OF END CAP MULTIPLY ACROSS EACH ROW THE MULTIPLIER x QTY USED TO GET THE EQUIVALENT FEET FOR THOSE COMPONENTS ADD UP ALL THE VALUES IN TH...

Page 10: ...10 VENTED RECIRCULATION WALL EXHAUST GRID EXHAUST R E C I R C U L A T I O N EXHAUST MUST BE RE TURNED TO THE SPACE typical installation examples...

Page 11: ...15 16 23 5 8 2 15 16 4 3 0 2 x a M 6 1 9 2 1 n i M 19 7 8 15 3 4 28 3 8 19 7 8 8 1 2 23 5 8 6 Front of hood Side of hood FIG 1 Top of hood dimensions MODEL A B XOCELING36 34 5 8 35 7 8 XOCELING42 40 5...

Page 12: ...e a recommended range of installation height over the cooking surface It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazar...

Page 13: ...into a custom canopy or cabinet refer to the cutout dimensions above for your particular model Gap around the unit should be minimized 1 8 to ensure a snug fit the cut out MODEL XOCELING36 XOCELING42...

Page 14: ...14 installation 1 3 2 1 Establish the direction of the air outlet hole to prepare the electrical connection and air evacuation...

Page 15: ...15 2 Fasten the telescopic brackets A and B to the joist with screws D Adjust the brackets to the dimensions shown in Fig 1 D A B...

Page 16: ...screws X and close panel P again For the various installations use screws and expansion plugs suitable for the type of wall e g reinforced concrete plasterboard etc If screws and dowels are supplied w...

Page 17: ...line to the appropriate wire following this color convention BLACK HOT LEG WHITE NEUTRAL GREEN YELLOW GROUND Polarity must be observed Unit must be properly grounded Use a double throw disconnect swit...

Page 18: ...and washing instructions are not followed the anti grease filters may present a fire hazard CLEANING STAINLESS STEEL Do not use corrosive detergents abrasive detergents or oven cleaners Do not use an...

Page 19: ...times a year more frequently if needed based on the amount of use and style of cooking CHANGING THE CARBON FILTERS Changing the filters is easy To Reduce the Risk of Fire and Shock use only conversio...

Page 20: ...hen the hood is off BUTTON T Activates and Deactivates the TIMER Function Pressing BUTTON T whether the blower is off or running will cause the motor to run at LOW speed for 5 minutes before shutting...

Page 21: ...breaker 2 VERY IMPORTANT after turning power back on to the unit you must press and hold both the and 0 buttons simultaneously within 5 seconds of re powering the unit NOTE If you do not press the bu...

Page 22: ...CULATION KITS FILTERS REPLACEMENT LIGHTS REMOTE CONTROLS ALL OF THESE PARTS AND MORE ARE AVAILABLE SIMPLY VISIT WWW XOAPPLIANCE COM and click on PARTS STORE OR CALL US AT 973 403 8900 access parts acc...

Page 23: ...vor of the original purchaser user at the original installation location Any such assignment or transfer shall void the warranties herein made and shall void all warranties express or implied includin...

Page 24: ...J ai travaill tr s dur sur ce manuel veuillez donc le lire XOCYLI ISLAND MOD LES XOCEILING36 XOCEILING42...

Page 25: ...liance com priority service for your xo product Ou par t l phone 973 403 8900 F LICITATIONS pour l achat de votre XO Avant de continuer prenez un instant pour enregistrer votre XO l adresse www xoappl...

Page 26: ...pr cautions Planification des conduits Exemples d installation Dimensions L INSTALLATION Hauteur de montage Installation Connexions lectriques ENTRETIEN Filtres Nettoyage Recirculation Remplacement de...

Page 27: ...sport l ext rieur travers un conduit d vacuation Ne pas vacuer l air dans des interstices tels qu entre des cloisons ou des plafonds dans des greniers des espaces confin s ou des garages ATTENTION N u...

Page 28: ...temp rature G Ne jamais laisser la cuisini re sans surveillance pendant la cuisson H Utiliser syst matiquement des ustensiles de cuisine adapt s au type et la quantit d aliments que l on pr pare AVER...

Page 29: ...ng Refrigeration and Air Conditioning Engineers ASHRAE et par les autorit s locales pr pos es C Au cours des op rations de d coupage ou de perforation du mur ou du plafond veiller ne pas endommager le...

Page 30: ...R LE NOMBRE DE RACCORDS voir tableau LORSQUE VOUS DEVEZ UTILISER DES RACCORDS ESSAYEZ DE LES S PARER AVEC DES SECTIONS DE 3 pi OU PLUS DE CONDUIT DROIT SUIVEZ TOUJOURS LES DIRECTIVES DU FABRICANT POUR...

Page 31: ...LISEZ ET LE TYPE DE CAPUCHON D EXTR MIT OF MULTIPLIEZ SUR CHAQUE LIGNE LE MULTIPLICATEUR X QUANTIT UTILIS E POUR OBTENIR LES PIEDS QUIVALENTS POUR CES COMPOSANTS AJOUTEZ TOUTES LES VALEURS DANS LA COL...

Page 32: ...32 VENTIL RECIRCULATION VENT D CHAPPEMENT MURAL CHAPPEMENT GRILLE L C H A P P E M E N T D E RECIRCULATION DOIT TRE RETOURN DANS L ESPACE exemples d installation typiques...

Page 33: ...3 5 8 2 15 16 4 3 0 2 x a M 6 1 9 2 1 n i M 19 7 8 15 3 4 28 3 8 19 7 8 8 1 2 23 5 8 6 Devant de la hotte C t de la hotte Haut de la hotte dimensions FIG 1 MOD LE A B XOCELING36 34 5 8 35 7 8 XOCELING...

Page 34: ...e hauteur d installation recommand e sur la surface de cuisson Il est important d installer la hotte la bonne hauteur de montage Les hottes mon t es trop bas peuvent entra ner des dommages caus s par...

Page 35: ...7 8 Pour installer la hotte dans un auvent ou une armoire personnalis e reportez vous aux dimensions de d coupe ci dessus pour votre mod le particulier L espace autour de l unit doit tre minimis 1 8 p...

Page 36: ...36 1 3 2 installation 1 D terminez la direction du trou de sortie d air pour pr parer le raccordement lectri que et l vacuation de l air...

Page 37: ...37 D A B 2 Fixez les supports t lescopiques A et B la solive l aide des vis D Ajustez les supports aux dimensions indiqu es sur la Fig 1...

Page 38: ...is X et refermez le panneau P Pour les diff rentes installations utilisez des vis et des chevilles expansion adapt es au type de mur par exemple b ton arm plaque de pl tre etc Si des vis et des chevil...

Page 39: ...au fil appropri en suivant cette convention de couleur NOIR PIED CHAUD BLANC NEUTRE VERT JAUNE SOL La polarit doit tre observ e L unit doit tre correctement mise la terre Utilisez un interrupteur de...

Page 40: ...ie des filtres anti graisse NETTOYAGE DE L ACIER INOXYDABLE N utilisez pas de d tergents corrosifs de d tergents abrasifs ou de nettoyants pour fours N utilisez aucun produit contenant de l eau de Jav...

Page 41: ...utilisation et du style de cuisson CHANGEMENT DES FILTRES CARBONE Changer les filtres est facile Pour r duire le risque d incendie et de choc utilisez uniquement les filtres du mod le de kit de conve...

Page 42: ...PUISSANCE fonctionnera m me lorsque la hotte est teinte BOUTON T Active et d sactive la fonction MINUTERIE En appuyant sur le BOUTON T que le ventilateur soit teint ou en marche le moteur fonc tionne...

Page 43: ...ur 2 TR S IMPORTANT apr s avoir rallum l appareil vous devez appuyer et maintenir les bou tons et 0 simultan ment dans les 5 secondes suivant la remise sous tension de l appareil REMARQUE Si vous n ap...

Page 44: ...FILTRES LUMI RES DE REMPLACEMENT T L COMMANDES TOUTES CES PI CES ET PLUS SONT DISPONIBLES VISITEZ SIMPLEMENT WW XOAPPLIANCE COM et cliquez sur LE MAGASIN DE PI CES OU APPELEZ NOUS AU 973 403 8900 acce...

Page 45: ...ine sur le site d installation d origine Une telle cession ou un tel transfert annulera les garanties faites dans les pr sentes et annulera toutes les garanties expresses ou implicites y compris toute...

Page 46: ...He trabajado mucho en este manual as que l alo XOCYLI ISLAND MODELOS XOCEILING36 XOCEILING42...

Page 47: ...ity service for your xo product Or por tel fono 973 403 8900 ENHORABUENA por la compra de su XO Antes de continuar t mese un momento para registrar su XO en www xoappliance com register your product E...

Page 48: ...STALACI N Altura de Montaje Instalaci n Conexiones el ctricas MANTENIMIENTO Filtros Limpieza Recirculaci n Sustituci n de la Luz FUNCIONAMIENTO Controles del Bot n Pulsador Conversi n de Aire de Repos...

Page 49: ...pto para aspirar materiales o vapores peligrosos o explosivos ATENCION Para evitar da os al motor y rumores y o h lices desbalanceadas evite que la unidad de alimentaci n llegue a contacto con esprays...

Page 50: ...e el quemador PRESTE MUCHA ATENCION DURANTE ESTA OPERACION PARA EVITAR QUEMADURAS Si las llamas no se extinguen inmediatamente EVACUE EL LUGAR Y LLAME A LOS BOMBEROS B NO TOQUE NUNCA UNA CAZUELA HIRVI...

Page 51: ...D El aparato debe estar siempre conectado a un agujero de evacuaci n hacia el exterior E La unidad deber ser conectada al suelo ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO USE SOLO TUBERIAS METALIC...

Page 52: ...ESORIOS consulte la tabla CUANDO DEBA USAR ACCESORIOS INTENTE SEPARARLOS CON SECCIONES DE 3 O M S DE CONDUCTO RECTO SIGA SIEMPRE LAS DIRECTRICES DEL FABRICANTE PARA EL EQUIPO DE COCINA QUE EST VENTILA...

Page 53: ...DO Y EL TIPO DE TAPA DE EXTREMO MULTIPLIQUE A LO LARGO DE CADA FILA EL MULTIPLICADOR x CANTIDAD UTILIZADA PARA OBTENER LOS PIES EQUIVALENTES PARA ESOS COMPONENTES SUME TODOS LOS VALORES EN LA COLUMNA...

Page 54: ...54 VENTILADO RECIRCULACI N ESCAPE DE PARED ESCAPE DE REJILLA EL ESCAPE DE RECIRCU LACI N DEBE SER DE VUELTO AL ESPACIO ejemplos t picos de instalaci n...

Page 55: ...4 3 0 2 x a M 6 1 9 2 1 n i M 19 7 8 15 3 4 28 3 8 19 7 8 8 1 2 23 5 8 6 Parte delantera de la campana Lado de la campana Parte superior de la campana dimensiones FIG 1 MODELO A B XOCELING36 34 5 8 35...

Page 56: ...endado de altura de instalaci n sobre la superficie de cocci n Es importante instalar la campana a la altura de montaje adecuada Las campanas montadas demasiado bajas podr an resultar en da os por cal...

Page 57: ...nete personalizado consulte las dimen siones de recorte anteriores para su modelo particular Se debe minimizar la brecha alrededor de la unidad 1 8 para garantizar un ajuste perfecto el recorte MODELO...

Page 58: ...58 1 3 2 instalaci n 1 Establezca la direcci n del orificio de salida del aire para preparar la conexi n el ctrica y la evacuaci n del aire...

Page 59: ...59 D A B 2 Fije los soportes telesc picos A y B a la viga con los tornillos D Ajuste los soportes a las dimensiones indicadas en Fig 1...

Page 60: ...rnillos X y vuelva a cerrar el panel P Para las distintas instalaciones utilice tornillos y tacos de expansi n adecuados al tipo de pared por ejemplo hormig n armado cart n yeso etc Si se suministran...

Page 61: ...iado siguiendo esta convenci n de color NEGRO TOMAS M LTIPLES BLANCO NEUTRO VERDE AMARILLO TIERRA Se debe respetar la polaridad La unidad debe estar correctamente conectada a tierra Utilice un interru...

Page 62: ...microfibra y pula en la direcci n del grano de acero inoxidable Las superficies pintadas deben limpiarse nicamente con agua tibia y detergente La limpieza y el mantenimiento regulares son la clave par...

Page 63: ...i n de la cantidad de uso y el estilo de cocci n CAMBIO DE LOS FILTROS DE CARBONO Cambiar los filtros es f cil Para reducir el riesgo de incendio y descarga utilice nicamente los filtros de modelo del...

Page 64: ...a campana est apagada BOT N T Activa y desactiva la funci n DEL TEMPORIZADOR Pulsar el BOT N T ya sea que el soplador est apagado o en funcionamiento har que el motor funcione a BAJA velocidad durante...

Page 65: ...yuntor 2 MUY IMPORTANTE despu s de volver a encender la unidad debe presionar y mantener pulsados los botones y 0 simult neamente dentro de los 5 segundos posteriores a volver a encender la unidad NOT...

Page 66: ...I N FILTROS LUCES DE REPUESTO MANDOS A DISTANCIA TODAS ESTAS PIEZAS Y M S EST N DISPONIBLES SIMPLEMENTE VISITE WWW XOAPPLIANCE COM y haga clic en LA TIENDA de piezas O LL MENOS al 973 403 8900 piezas...

Page 67: ...usuario ori ginal en el lugar de instalaci n original Cualquier cesi n o transferencia anular las garant as aqu hechas y anular todas las garant as expresas o impl citas incluyendo cualquier garant a...

Page 68: ...3011000160100 00...

Reviews: