DUCT FITTINGS:

This Hood Must Use an

6" Round Duct. It Can

Transition to 3-1/4" x

10" or 3-1/4" x 12" Duct.

Use this chart to compu-

te maximum permissible 

lengths for duct runs to 

outdoors.

NOTE:

 

Do not exceed maxi-

mum permissible equivalent 

lengths!

Maximum duct length: 

100 feet for range ho-

ods.
Flexible ducting:

If flexible metal ducting 

is used, all the equivalent 

feet values in the table 

should be doubled. The 

flexible metal duct should 

be straight and smooth 

and extended as much as 

possible.
DO NOT use flexible plastic 

ducting.

NOTE:

 

Any home ventilation 

system, such as a ventilation 

hood, may interrupt the 

proper flow of combustion 

air and exhaust required 

by fireplaces, gas furnaces, 

gas water heaters and other 

naturally vented systems. To 

minimize the chance of in-

terruption of such naturally 

vented systems, follow the 

heating equipment manu-

facturer’s guidelines and 

safety standards such as 

those published by NFPA.

Duct 

Piece:

Dimensions:

Equivalent 

Number 

Length*:

Quantity

Used:

Total

Equivalent

Length:

Round, straight 1 ft. (per foot 

lenhgth)

3-1/4" x 10" 

straight

1 ft. (per foot 

lenhgth)

90° elbow

12 ft.

45° elbow

7 ft.

3-1/4" x 10"

3-1/4" x 12"

90° elbow

14 ft.

10 ft.

3-1/4" x 10"

3-1/4" x 12"

45° elbow

8 ft.

6 ft.

3-1/4" x 10"

3-1/4" x 12"

90° elbow

33 ft.

24 ft.

6" round to 

rectangular

2 ft.

Rectangular to 

8" round

2 ft.

3-1/4" x 10"

3-1/4" x 12"

6" round to 

rectangular 

transition 90° 

elbow

4 ft.

4 ft.

3-1/4" x 10"

3-1/4" x 12"

Rectangular to 

6" transition 

90° elbow

4 ft.

4 ft.

Round wall 

cap with 

dramper

24 ft.

3-1/4" x 10"

3-1/4" x 12"

Rectangular 

wall cap with 

dramper

24 ft.

18 ft.

Round roof 

cap

33 ft.

*Actual length of straight duct plus duct 

fitting equivalent. Equivalent length of duct 

pieces reflect requirements for good venting 

performance with any ventilation hood.

Total Duct Run =

Summary of Contents for XOC24SMUA

Page 1: ...de utilización USA F E XOC24SMUA XOC30SMUA XOC36S XOC30S NEED HELP Call our ventilation experts toll free al 800 966 8300 AVEZ VOUS BESOIN D AIDE Contactez nos experts au numéro gratuit 800 966 8300 NECESITA AYUDA Póngase en contacto con nuestros expertos a través del número gratis 800 966 8300 ...

Page 2: ...the original purchaser for products purchased for ordinary home use in North America Should you require service for your XO product call a product service specialist at 800 966 8300 Improper Installation Service trips to the home to teach you how to use the product Resetting circuit breakers Damage caused after delivery EXPECT MORE FROM XO When buying any XO appliance you can be confident you have...

Page 3: ...s and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for further information and requirements WARNING TO REDUCETHE RISK OF FIRE ELECTRIC SHOCK OR INJURYTO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you h...

Page 4: ...ow you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit aBased on kitchen firesafety tips published by NFPA Proper maintenance of the Range Hood will assure proper performance of the unit INSTALLATION INSTRUCTIONS WARNING TO RED...

Page 5: ... the appliance C No food must be cooked flambè underneath the hood D The use of an unprotected flame is dangerous for the filters and could cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F Before performing any mainteinance operation disconnect the hood from the elec trical service The manufacturers will not to accept any responsability for eventual damag...

Page 6: ...terruption of such naturally vented systems follow the heating equipment manu facturer s guidelines and safety standards such as those published by NFPA Duct Piece Dimensions Equivalent Number Length Quantity Used Total Equivalent Length Round straight 1 ft per foot lenhgth 3 1 4 x 10 straight 1 ft per foot lenhgth 90 elbow 12 ft 45 elbow 7 ft 3 1 4 x 10 3 1 4 x 12 90 elbow 14 ft 10 ft 3 1 4 x 10 ...

Page 7: ...pe or Duct Tape INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the hood and the outside 2 A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof or wall cap Connect 6 round metal...

Page 8: ... 8 Hood Specifications Front of hood Side of hood Top of hood Mounting height and clearance Product dimensions and clearance XOC24SMUA XOC30SMUA XOC36S XOC30S ...

Page 9: ...r to make handling the device easier This product can be installed in 3 different ways depending on the model and on your requirements 1 installation of the hood on the lower part of the wall unit 2 installation of the hood on the lower part of the wall unit on a divider support 3 Installation of the hood on the lower part of the wall unit only for 30 ...

Page 10: ...cated in figure 4 step 2 3 Build the hood in the wall unit and make sure the 2 side springs F are connected cor rectly Fasten the hood to the wall unit using the screwdriver and the relative screws M and tighten until the device is firmly against the wall unit figure 4 step 2 4 Remove pin Y from bracket A Then place the insert X on the slot of the bracket A as indicated in figure 4 step 3 Match th...

Page 11: ...asten screw D to the wall unit as indicated in figure 4 step 4 Once you have fastened the hood to the wall unit adjust the spacer L with the screws P to make the device line up with the rear wall unit figure 4 step 5 IMPORTANT The range hood must be secured to wall studs or use drywall anchors capable of supporting 75 lbs ...

Page 12: ... the wall unit and make sure the 2 side springs F are connected correctly Fasten the hood to the wall unit using the screwdriver and the relative screws M and tighten until the device is firmly against the wall unit figure 4 step 2 5 Fasten the hood to the upper wall unit as indicated in figure 5 step 6 Once you have fastened the hood to the wall unit adjust the spacer L with screws P to make the ...

Page 13: ... 13 ...

Page 14: ... 14 ...

Page 15: ... up with that traced in figure 6 step 1 3 Mark and drill the 4 fixing holes figure 6 step 2 Fasten the 2 brackets G to the wall unit using the 4 screws D figure 6 step 3 Fasten the hood to bracket G using the 4 screws E figure 6 step 4 5 4 Remove pin Y from bracket A Then place the insert X on the slot of the bracket A as indicated in figure 4 step 3 Match the C screws with the L wascher and fix t...

Page 16: ...the hood to the wall unit adjust the spacer L with screws P to make the device line up the rear wall unit figure 4 step 5 IMPORTANT The range hood must be secured to wall studs or use drywall anchors capable of supporting 75 lbs ...

Page 17: ...rcuit and protected by a 15 or 20 amp circuit breaker or time delay fuse Wiring must be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Route house wiring as close to the installation location as possible in the ceiling or back wall Refer to Wiring Locations on page 18 Connect the hood wiring to the house wiring in acco...

Page 18: ...ox cover securing it using the screws that were previously removed The appliance should be installed at a minimum height of 24 up to a maximum height of 32 for op timal performance If a connection ductwork com posed of two parts is used the upper part must be placed outside the lower part Do not connect the range hood exhaust duct air to the same duct air used to exhaust hot air or fumes from othe...

Page 19: ... 19 Ductless Recirculating Option Carbon filter kit XOC24SMUA XOC30SMUA XOC36S XOC30S follow the indi cations described in the additional sheet to install the kit ...

Page 20: ... 20 ...

Page 21: ... 21 ...

Page 22: ... After ten minutes the motor switches off and the LED of key F remains switched on with a fixed light until the motor starts up again at the first speed after fifty minutes and keys F and C start to flash again for ten minutes and so on By pressing any key for the exclusion of the hood light the hood will return immediately to its normal functioning e g if key D is pressed the clean air function i...

Page 23: ...o the room The filters are not washable or re usable and must be replaced at least once every four months The active carbon filter saturation level depends on the frequency with which the appliance is used the type of cooking performed and the regularity with which the anti grease filters are cleaned Cleanthecookerhoodfrequently bothinsideandoutside usingaclothwhichhasbeen dampened with denatured ...

Page 24: ... compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals with may be harmful Rinse with water after exposure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only Replacing the aluminum panels To replace the aluminium panels simply pull handle G as shown in Fig 9 ...

Page 25: ... 25 Replacing halogen light bulbs To replace the dichroic lamps rotate the lamp anticlockwise by means of a suction cup as shown in figure Replace the bulbs with new ones of the same type ...

Page 26: ... 26 XOC24SMUA XOC30SMUA XOC36S XOC30S ...

Page 27: ... 27 OPTIONS AND ACCESSORIES Model XORFRND Ductless Recirculating Filter Kit Model XORFK12 Ductless Recirculating Filter Kit ...

Page 28: ...dware package packed with the hood and check contents Adjusting brackets Aluminum filter TYPE DESCRIPTION N A 1 8 x 1 4 3 B 3 16 x 9 16 4 Supply of side fixing brackets on wall unit only for 30 1 8 x 1 4 N 4 Side fixing brack ets on wall unit no 2 3 16 x 9 16 N 4 1 4 6 16 ...

Page 29: ...ooking surface Aluminum Mesh Filters Trap airborne smoke and grease particles They can be easily be removed for dishwasher safe cleaning Mounting Height from cooking surface 24 32 Duct Options and Electrical Requirements 6 inch duct required Ductless Option for applications where no ducting in available Model XOC24SMUA XOC30SMUA AC 120v 60Hz 3 5amp Model XOC36S XOC30S AC 120v 60Hz 4 35amp Options ...

Reviews: