background image

- 3 -

   IMPORTANT SAFETY INSTRUCTIONS

   FOR RESIDENTIAL USE ONLY

   READ AND SAVE THESE INSTRUCTIONS

   PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

   IMPORTANT: Save these Instructions for the Local Electrical Inspectors use.

   INSTALLER: Please leave these Instructions with this unit for the owner.

   OWNER: Please retain these instructions for future reference.

   Take care when using cleaning agents or detergents.

   Suitable for use in household cooking area.

   WARNING - To reduce the risk of fire or electric shock, do not use this fan with any 

Solid-State Speed Control Device.

   CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air out-

side – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl 

spaces, or garages.

   CAUTION - For general ventilating use only. Do not use to exhaust hazardous or ex-

plosive materials and vapors.

   CAUTION - To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

   CAUTION - Please read specification label on product for further information and  

    requirements.

   WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING:

A.  Use this unit only in the manner intended by the manufacturer. If you have questions, 

contact the manufacturer.

B.  Before servicing or cleaning unit, switch power off at service panel and lock the serv-

ice  disconnecting  means  to  prevent  power  from  being  switched  on  accidentally. 

When the service disconnecting means cannot be locked, securely fasten a promi-

nent warning device, such as a tag, to the service panel.

   WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.  Never leave surface units unattended at high settings. Boilovers cause smoking and 

greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B.  Always  turn  hood  ON  when  cooking  at  high  heat  or  when  flambeing  foods  (i.e. 

ENGLISH

USA

Summary of Contents for XOB24S

Page 1: ...l de utilizaci n USA F E XOB24S XOB30S XOB36S XOB42S NEED HELP Call our ventilation experts toll free al 800 966 8300 AVEZ VOUS BESOIN D AIDE Contactez nos experts au num ro gratuit 800 966 8300 NECES...

Page 2: ...ginal purchaser for products purchased for ordinary home use in North America Should you require service for your XO product call a product service specialist at 800 966 8300 Improper Installation Ser...

Page 3: ...and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for f...

Page 4: ...guisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called...

Page 5: ...s after a prolonged use of the appliance C No food must be cooked flamb underneath the hood D The use of an unprotected flame is dangerous for the filters and could cause fires E Watch constantly the...

Page 6: ...erruption of such naturally vented systems follow the heating equipment manu facturer s guidelines and safety standards such as those published by NFPA Duct Piece Dimensions Equivalent Number Length Q...

Page 7: ...e or Duct Tape INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the hood and the outside 2 A straight short duct run will allow...

Page 8: ...8 Hood Specifications Front of hood Side of hood Top of hood Mounting height and clearance Product dimensions and clearance XOB24S XOB30S XOB36S XOB42S...

Page 9: ...appliance has been adjusted definitely fix the hood using the screws A Fig 2 For the vari ous installations use screws and screw anchors suited to the type of wall e g reinforced concrete plasterboar...

Page 10: ...t be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Route house wiring as close to the installation location as possible...

Page 11: ...h the hole on the box cover 3 Secure the power supply conduit to the cover 4 Connect the wires of the hood to those of the power supply as described Fig 3B BLACK L line WHITE N neutral GREEN YELLOW G...

Page 12: ...tric cooker stove or 30 from gas or combined cooker stoves If a connec tion ductwork composed of two parts is used the upper part must be placed outside the lower part Do not connect the range hood e...

Page 13: ...th of the support bracket of the upper flue Fig 6 Then fix it to the ceiling using the screws A Fig 6 in such a way that it is in line with your hood and respecting the distance from the ceiling indic...

Page 14: ...and place them on a flat surface Carbon filter kit XORFK04 The kit includes an air diverter A 2 screws and 2 expan sions plugs B and 2 round filters C Fig 2 Make a mark on the wall and then drill a h...

Page 15: ...o holes as shown in the figure hole diameter 1 4 inches Once the two holes have been drilled fasten the air diverter A to the bracket H Fig 5 Fasten the air diverter permanently to the wall with a scr...

Page 16: ...n it using the 2 screws E Fig 8 Remove the aluminum panels by pulling the lever 1 out and pushing downwards 2 Fig 9 The filters C must be applied to the suction unit inside the hood centering them ins...

Page 17: ...off and the LED of key F remains switched on with a fixed light until the motor starts up again at the first speed after fifty minutes and keys F and C start to flash again for ten minutes and so on...

Page 18: ...hich is released back into the room The filters are not washable or re usable and must be replaced at least once every four months The active carbon filter saturation level depends on the frequency wi...

Page 19: ...e causing rust DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals with ma...

Page 20: ...In case of necessity it can be replaced only by spe cialized personnel Replacing halogen light bulbs To replace the halogen lamps B from the inside of the cooker hood press downwards with two fingers...

Page 21: ...21 XOB24S XOB30S XOB36S XOB42S...

Page 22: ...22 OPTIONS AND ACCESSORIES Model XORFK04 Ductless Recirculating Filter Kit Model XOEDCB Duct Cover Extension This accessory is available for installation with ceiling heights above 9ft to 10ft...

Page 23: ...e decorative flue to the mounting bracket 2 Duct bracket Aluminum filter 2 piece decorative duct cover dimension shown for reference only INSTALLATION PREPARATION Check installation hardware Locate th...

Page 24: ...ning Standard Chimney fits ceilings up to 9ft tall Optional extension for ceilings up to10ft Mounting Height from cooking surface 27 32 Duct Options and Electrical Requirements 6 inch duct required Du...

Reviews: